METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS

Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develo...

Full description

Saved in:
Bibliographic Details
Date:2018
Main Authors: Suprunovska, N. I., Shcherba, M. A.
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2018
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2018.5.07
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-144869
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2018-10-19T16:35:53Z
collection OJS
language English
topic electric discharge installation
capacitor charge
charge voltage
transients
nonzero initial conditions
621.3.072
spellingShingle electric discharge installation
capacitor charge
charge voltage
transients
nonzero initial conditions
621.3.072
Suprunovska, N. I.
Shcherba, M. A.
METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
topic_facet electric discharge installation
capacitor charge
charge voltage
transients
nonzero initial conditions
621.3.072
электроразрядная установка
заряд конденсатора
зарядное напряжение
переходные процессы
ненулевые начальные условия
621.3.072
format Article
author Suprunovska, N. I.
Shcherba, M. A.
author_facet Suprunovska, N. I.
Shcherba, M. A.
author_sort Suprunovska, N. I.
title METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_short METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_full METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_fullStr METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_full_unstemmed METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
title_sort method for voltage control in charge circuit of electric discharge installations with two capacitors under nonzero initial conditions
title_alt METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
description Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit. Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms – either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2018
url http://eie.khpi.edu.ua/article/view/2074-272X.2018.5.07
work_keys_str_mv AT suprunovskani methodforvoltagecontrolinchargecircuitofelectricdischargeinstallationswithtwocapacitorsundernonzeroinitialconditions
AT shcherbama methodforvoltagecontrolinchargecircuitofelectricdischargeinstallationswithtwocapacitorsundernonzeroinitialconditions
first_indexed 2025-07-17T11:47:20Z
last_indexed 2025-07-17T11:47:20Z
_version_ 1850411803432976384
spelling eiekhpieduua-article-1448692018-10-19T16:35:53Z METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS Suprunovska, N. I. Shcherba, M. A. electric discharge installation capacitor charge charge voltage transients nonzero initial conditions 621.3.072 электроразрядная установка заряд конденсатора зарядное напряжение переходные процессы ненулевые начальные условия 621.3.072 Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit. Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms – either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5. Цель. Целью статьи является анализ переходных процессов в зарядной цепи электроразрядных установок с двумя конденсаторами с учетом изменения начальных условий протекания таких процессов (начального напряжения на конденсаторах и начального тока в зарядной цепи), а также разработка метода регулирования зарядного напряжения таких установок, используя целенаправленное изменение указанных начальных условий. Методика. Для проведения исследований использовались положения теоретической электротехники, теория электрических цепей, математическое моделирование в программном пакете MathCAD 12. Результаты. Получены аналитические выражения и графические зависимости, устанавливающие количественную связь между значением максимального зарядного напряжения установок и величинами начального напряжения на ее конденсаторах и начального тока в цепи. Предложен метод регулирования напряжения заряда электроразрядных установок с двумя накопительными конденсаторами, использующий целенаправленное изменение их начальных напряжений и начального тока в зарядной цепи. Научная новизна. Установлено, что напряжение заряда установки можно регулировать, используя два механизма влияния – как изменяя начальный ток в зарядной цепи (прерыванием переходного процесса заряда первого конденсатора в определенный момент времени), так и используя ненулевое начальное напряжение на заряжаемом втором конденсаторе. При этом напряжение заряда можно изменять в 2 раза. Практическое значение. Использование данного метода позволяет получить разрядные импульсы сложной формы в технологической нагрузке, поскольку максимальные напряжения заряда первого и второго конденсаторов могут отличаться в 1,5 раза. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2018-10-19 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2018.5.07 10.20998/2074-272X.2018.5.07 Electrical Engineering & Electromechanics; No. 5 (2018); 39-43 Электротехника и Электромеханика; № 5 (2018); 39-43 Електротехніка і Електромеханіка; № 5 (2018); 39-43 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/2074-272X.2018.5.07/142859 Copyright (c) 2018 N. I. Suprunovska, M. A. Shcherba https://creativecommons.org/licenses/by-nc/4.0