ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER

Purpose. Elimination of the error of the inverter current control loop by improving its structure and justifying the parameters, which will ensure compliance with the current quality standard at the common coupling to the distribution grid of the load and the multi-functional grid inverter at the ou...

Full description

Saved in:
Bibliographic Details
Date:2019
Main Authors: Shavelkin, O. O., Kaplun, V. V., Shvedchikova, I. A.
Format: Article
Language:English
Ukrainian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2019
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2019.4.05
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-176179
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2019-08-18T09:05:43Z
collection OJS
language English
Ukrainian
topic multi-functional single-phase grid-connected inverter
nonlinear load
PWM
current control loop
current error compensation
THD
simulation
621.314.26
spellingShingle multi-functional single-phase grid-connected inverter
nonlinear load
PWM
current control loop
current error compensation
THD
simulation
621.314.26
Shavelkin, O. O.
Kaplun, V. V.
Shvedchikova, I. A.
ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
topic_facet багатофункціональний мережевий інвертор
нелінійне навантаження
ШІМ
контур регулювання струму
компенсація похибки струму
коефіцієнт гармонік
моделювання
621.314.26
multi-functional single-phase grid-connected inverter
nonlinear load
PWM
current control loop
current error compensation
THD
simulation
621.314.26
format Article
author Shavelkin, O. O.
Kaplun, V. V.
Shvedchikova, I. A.
author_facet Shavelkin, O. O.
Kaplun, V. V.
Shvedchikova, I. A.
author_sort Shavelkin, O. O.
title ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
title_short ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
title_full ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
title_fullStr ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
title_full_unstemmed ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER
title_sort error elimination for current control loop for multi-functional single-phase grid-connected inverter
title_alt УСУНЕННЯ ПОХИБКИ КОНТУРУ РЕГУЛЮВАННЯ СТРУМУ БАГАТОФУНКЦІОНАЛЬНОГО ОДНОФАЗНОГО МЕРЕЖЕВОГО ІНВЕРТОРА
description Purpose. Elimination of the error of the inverter current control loop by improving its structure and justifying the parameters, which will ensure compliance with the current quality standard at the common coupling to the distribution grid of the load and the multi-functional grid inverter at the output of the renewable source of electrical energy. Methodology. Synthesis of structure of current control loop based on analysis of processes in electrical circuits and computer simulation. Results. Relationships for determining the input voltage of the inverter, reactor inductance and modulation frequency in accordance with the grid voltage, the maximum values of the inverter current and the amplitude of its ripple when combining the function of the active power filter. Dependencies of the amplitude of the pulsations of the output current of the inverter and the errors in the fundamental harmonic in accordance with the voltage at the input of the inverter, the modulation frequency and inductance of the output reactor are obtained. Originality. The structure of the inverter current control loop has been improved with a combination of proportional, integrating and differentiating links, and their parameters have been determined to ensure compensation of the disturbing action on input of the reference and compensation of the error of current from the disturbing action of the grid voltage regardless of its value. Practical value. The obtained solutions are the basis for the design of converters of electric power systems with renewable sources of electricity with improved energy efficiency. 
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2019
url http://eie.khpi.edu.ua/article/view/2074-272X.2019.4.05
work_keys_str_mv AT shavelkinoo erroreliminationforcurrentcontrolloopformultifunctionalsinglephasegridconnectedinverter
AT kaplunvv erroreliminationforcurrentcontrolloopformultifunctionalsinglephasegridconnectedinverter
AT shvedchikovaia erroreliminationforcurrentcontrolloopformultifunctionalsinglephasegridconnectedinverter
AT shavelkinoo usunennâpohibkikontururegulûvannâstrumubagatofunkcíonalʹnogoodnofaznogomereževogoínvertora
AT kaplunvv usunennâpohibkikontururegulûvannâstrumubagatofunkcíonalʹnogoodnofaznogomereževogoínvertora
AT shvedchikovaia usunennâpohibkikontururegulûvannâstrumubagatofunkcíonalʹnogoodnofaznogomereževogoínvertora
first_indexed 2025-07-17T11:47:42Z
last_indexed 2025-07-17T11:47:42Z
_version_ 1850411850206806017
spelling eiekhpieduua-article-1761792019-08-18T09:05:43Z ERROR ELIMINATION FOR CURRENT CONTROL LOOP FOR MULTI-FUNCTIONAL SINGLE-PHASE GRID-CONNECTED INVERTER УСУНЕННЯ ПОХИБКИ КОНТУРУ РЕГУЛЮВАННЯ СТРУМУ БАГАТОФУНКЦІОНАЛЬНОГО ОДНОФАЗНОГО МЕРЕЖЕВОГО ІНВЕРТОРА Shavelkin, O. O. Kaplun, V. V. Shvedchikova, I. A. багатофункціональний мережевий інвертор нелінійне навантаження ШІМ контур регулювання струму компенсація похибки струму коефіцієнт гармонік моделювання 621.314.26 multi-functional single-phase grid-connected inverter nonlinear load PWM current control loop current error compensation THD simulation 621.314.26 Purpose. Elimination of the error of the inverter current control loop by improving its structure and justifying the parameters, which will ensure compliance with the current quality standard at the common coupling to the distribution grid of the load and the multi-functional grid inverter at the output of the renewable source of electrical energy. Methodology. Synthesis of structure of current control loop based on analysis of processes in electrical circuits and computer simulation. Results. Relationships for determining the input voltage of the inverter, reactor inductance and modulation frequency in accordance with the grid voltage, the maximum values of the inverter current and the amplitude of its ripple when combining the function of the active power filter. Dependencies of the amplitude of the pulsations of the output current of the inverter and the errors in the fundamental harmonic in accordance with the voltage at the input of the inverter, the modulation frequency and inductance of the output reactor are obtained. Originality. The structure of the inverter current control loop has been improved with a combination of proportional, integrating and differentiating links, and their parameters have been determined to ensure compensation of the disturbing action on input of the reference and compensation of the error of current from the disturbing action of the grid voltage regardless of its value. Practical value. The obtained solutions are the basis for the design of converters of electric power systems with renewable sources of electricity with improved energy efficiency.  Мета. Усунення похибки контуру регулювання струму інвертора шляхом удосконалення його структури та обґрунтування параметрів, що сприятиме відповідності стандарту якості струму в точці підключення до розподільчої мережі навантаження і багатофункціонального мережевого інвертора на виході поновлювального джерела електроенергії. Методика. Синтез структури контуру регулювання струму на базі аналізу процесів у електричних колах з використанням комп’ютерного моделювання. Результати. Одержані залежності амплітуди пульсацій вихідного струму інвертора і похибки за основною гармонікою від напруги на вході інвертора, частоти ШІМ і індуктивності реактора. Співвідношення для визначення значень вхідної напруги інвертора, індуктивності реактору та частоти ШІМ згідно напрузі мережі, максимальних значень струму інвертора та амплітуди його пульсацій за суміщенням функції силового активного фільтра. Наукова новизна. Удосконалено структуру контуру регулювання струму зі сполученням пропорційної, інтегруючої та диференціючої ланок і визначені їх параметри для забезпечення компенсації збурюючої дії за завданням і компенсації похибки струму від збурюючої дії напруги мережі незалежно від її значення. Практичне значення. Отримані рішення є основою для проектування перетворювачів для систем з поновлювальними джерелами електроенергії з покращеною енергоефективністю. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2019-08-18 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2019.4.05 10.20998/2074-272X.2019.4.05 Electrical Engineering & Electromechanics; No. 4 (2019); 35-40 Электротехника и Электромеханика; № 4 (2019); 35-40 Електротехніка і Електромеханіка; № 4 (2019); 35-40 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/2074-272X.2019.4.05/176016 http://eie.khpi.edu.ua/article/view/2074-272X.2019.4.05/176017 Copyright (c) 2019 O. O. Shavelkin, V. V. Kaplun, I. A. Shvedchikova https://creativecommons.org/licenses/by-nc/4.0