PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS

Causes of premature failure of medium-power two-pole induction motor windings after the windings first repair are revealed. Recommendations for the medium-power two-pole induction motor winding reliability improvement are given.

Saved in:
Bibliographic Details
Date:2013
Main Authors: Lushchik, V. D., Polezіn, S. Yu., Antipko, G. S.
Format: Article
Language:Ukrainian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2013
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.06
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
_version_ 1856543136480755712
author Lushchik, V. D.
Polezіn, S. Yu.
Antipko, G. S.
author_facet Lushchik, V. D.
Polezіn, S. Yu.
Antipko, G. S.
author_sort Lushchik, V. D.
baseUrl_str
collection OJS
datestamp_date 2026-02-08T07:56:50Z
description Causes of premature failure of medium-power two-pole induction motor windings after the windings first repair are revealed. Recommendations for the medium-power two-pole induction motor winding reliability improvement are given.
first_indexed 2025-07-17T11:44:16Z
format Article
id eiekhpieduua-article-19794
institution Electrical Engineering & Electromechanics
language Ukrainian
last_indexed 2026-02-08T07:58:25Z
publishDate 2013
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
record_format ojs
spelling eiekhpieduua-article-197942026-02-08T07:56:50Z PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS ПРЕЖДЕВРЕМЕННЫЙ ВЫХОД ИЗ СТРОЯ ОБМОТОК ДВУХПОЛЮСНЫХ АСИНХРОННЫХ ДВИГАТЕЛЕЙ СРЕДНЕЙ МОЩНОСТИ ПЕРЕДЧАСНИЙ ВИХІД З ЛАДУ ОБМОТОК ДВОПОЛЮСНИХ АСИНХРОННИХ ДВИГУНІВ СЕРЕДНЬОЇ ПОТУЖНОСТІ Lushchik, V. D. Polezіn, S. Yu. Antipko, G. S. induction motor winding premature failure reliability repair 621.313.3 621.313.3 621.313.3 Causes of premature failure of medium-power two-pole induction motor windings after the windings first repair are revealed. Recommendations for the medium-power two-pole induction motor winding reliability improvement are given. Определены причины преждевременного выхода из строя обмоток двухполюсных асинхронных двигателей средней мощности после первого ремонта обмоток. Даны рекомендации по повышению их надежности. Встановлені причини передчасного згорання обмоток двополюсних асинхронних двигунів середньої потужності після першого ремонту обмоток. Надані рекомендації по підвищенню їх надійності. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2013-12-29 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.06 10.20998/2074-272X.2013.6.06 Electrical Engineering & Electromechanics; No. 6 (2013); 37-39 Электротехника и Электромеханика; № 6 (2013); 37-39 Електротехніка і Електромеханіка; № 6 (2013); 37-39 2309-3404 2074-272X uk http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.06/17418 Copyright (c) 2015 V. D. Lushchik, S. Yu. Polezіn, G. S. Antipko https://creativecommons.org/licenses/by-nc/4.0
spellingShingle induction motor
winding
premature failure
reliability
repair
621.313.3
Lushchik, V. D.
Polezіn, S. Yu.
Antipko, G. S.
PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title_alt ПРЕЖДЕВРЕМЕННЫЙ ВЫХОД ИЗ СТРОЯ ОБМОТОК ДВУХПОЛЮСНЫХ АСИНХРОННЫХ ДВИГАТЕЛЕЙ СРЕДНЕЙ МОЩНОСТИ
ПЕРЕДЧАСНИЙ ВИХІД З ЛАДУ ОБМОТОК ДВОПОЛЮСНИХ АСИНХРОННИХ ДВИГУНІВ СЕРЕДНЬОЇ ПОТУЖНОСТІ
title_full PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title_fullStr PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title_full_unstemmed PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title_short PREMATURE FAILURE OF MEDIUM-POWER TWO-POLE INDUCTION MOTOR WINDINGS
title_sort premature failure of medium-power two-pole induction motor windings
topic induction motor
winding
premature failure
reliability
repair
621.313.3
topic_facet induction motor
winding
premature failure
reliability
repair
621.313.3
621.313.3
621.313.3
url http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.06
work_keys_str_mv AT lushchikvd prematurefailureofmediumpowertwopoleinductionmotorwindings
AT polezínsyu prematurefailureofmediumpowertwopoleinductionmotorwindings
AT antipkogs prematurefailureofmediumpowertwopoleinductionmotorwindings
AT lushchikvd preždevremennyjvyhodizstroâobmotokdvuhpolûsnyhasinhronnyhdvigatelejsrednejmoŝnosti
AT polezínsyu preždevremennyjvyhodizstroâobmotokdvuhpolûsnyhasinhronnyhdvigatelejsrednejmoŝnosti
AT antipkogs preždevremennyjvyhodizstroâobmotokdvuhpolûsnyhasinhronnyhdvigatelejsrednejmoŝnosti
AT lushchikvd peredčasnijvihídzladuobmotokdvopolûsnihasinhronnihdvigunívserednʹoípotužností
AT polezínsyu peredčasnijvihídzladuobmotokdvopolûsnihasinhronnihdvigunívserednʹoípotužností
AT antipkogs peredčasnijvihídzladuobmotokdvopolûsnihasinhronnihdvigunívserednʹoípotužností