THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS

The paper presents some principles and results of numerical field calculation and the corresponding harmonic analysis of magnetic field in the active zone of a large turbogenerator under load conditions. In addition to the traditional coordinate function of the magnetic induction, its time functions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2013
Hauptverfasser: Milykh, V. I., Polyakova, N. V.
Format: Artikel
Sprache:Russian
Veröffentlicht: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2013
Schlagworte:
Online Zugang:http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.07
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-19795
record_format ojs
spelling eiekhpieduua-article-197952025-12-02T15:24:20Z THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS РАСЧЕТНЫЙ И ГАРМОНИЧЕСКИЙ АНАЛИЗ МАГНИТНЫХ ПОЛЕЙ В АКТИВНОЙ ЗОНЕ ТУРБОГЕНЕРАТОРА В РЕЖИМЕ НАГРУЗКИ РАСЧЕТНЫЙ И ГАРМОНИЧЕСКИЙ АНАЛИЗ МАГНИТНЫХ ПОЛЕЙ В АКТИВНОЙ ЗОНЕ ТУРБОГЕНЕРАТОРА В РЕЖИМЕ НАГРУЗКИ Milykh, V. I. Polyakova, N. V. turbogenerator magnetic field numerical field calculation load mode magnetic induction magnetic flux linkage coordinate function time function harmonic analysis 621.313 турбогенератор магнитное поле численно-полевой расчет режим нагрузки магнитная индукция магнитное потокосцепление координатная функция временная функция гармонический анализ 621.313 621.313 The paper presents some principles and results of numerical field calculation and the corresponding harmonic analysis of magnetic field in the active zone of a large turbogenerator under load conditions. In addition to the traditional coordinate function of the magnetic induction, its time functions are considered at fixed points and at rotating rotor linked points in the gap. The stator magnetic flux linkage functions are also examined. It is revealed that these magnetic induction functions, which are different from sine curves, fail to provide the basis for determining time functions of magnetic flux linkage and the stator winding EMF that are close to sine waves. Представлены принципы и результаты численно-полевого расчета и соответствующего гармонического анализа магнитного поля в активной зоне крупного турбогенератора в режиме нагрузки. Кроме традиционной координатной функции магнитной индукции, в зазоре рассмотрены ее временные функции в неподвижных точках и в точках, связанных с вращающимся ротором, а также функции магнитного потокосцепления обмотки статора. Выявлено, что эти функции магнитной индукции, которые сильно отличаются от синусоид, не могут быть основой определения временных функций магнитного потокосцепления и ЭДС обмотки статора, близких к синусоидам. Подано принципи і результати чисельно-польового розрахунку і відповідного гармонійного аналізу магнітного поля в активній зоні крупного турбогенератора в режимі навантаження. Окрім традиційної координатної функції магнітної індукції, в проміжку розглянуті її часові функції в нерухомих точках і в точках, пов'язаних з ротором, що обертається, а також функції магнітного потокозчеплення обмотки статора. Зроблений висновок, що ці функції магнітної індукції, які сильно відрізняються від синусоїд, не можуть бути основою визначення часових функцій магнітного потокозчеплення і ЕРС обмотки статора, які близькі до синусоїд. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2013-12-29 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.07 10.20998/2074-272X.2013.6.07 Electrical Engineering & Electromechanics; No. 6 (2013); 40-45 Электротехника и Электромеханика; № 6 (2013); 40-45 Електротехніка і Електромеханіка; № 6 (2013); 40-45 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.07/17419 Copyright (c) 2015 V. I. Milykh, N. V. Polyakova https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2025-12-02T15:24:20Z
collection OJS
language Russian
topic turbogenerator
magnetic field
numerical field calculation
load mode
magnetic induction
magnetic flux linkage
coordinate function
time function
harmonic analysis
621.313
spellingShingle turbogenerator
magnetic field
numerical field calculation
load mode
magnetic induction
magnetic flux linkage
coordinate function
time function
harmonic analysis
621.313
Milykh, V. I.
Polyakova, N. V.
THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
topic_facet turbogenerator
magnetic field
numerical field calculation
load mode
magnetic induction
magnetic flux linkage
coordinate function
time function
harmonic analysis
621.313
турбогенератор
магнитное поле
численно-полевой расчет
режим нагрузки
магнитная индукция
магнитное потокосцепление
координатная функция
временная функция
гармонический анализ
621.313
621.313
format Article
author Milykh, V. I.
Polyakova, N. V.
author_facet Milykh, V. I.
Polyakova, N. V.
author_sort Milykh, V. I.
title THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
title_short THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
title_full THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
title_fullStr THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
title_full_unstemmed THEORETICAL AND HARMONIC ANALYSIS OF MAGNETIC FIELDS IN THE ACTIVE ZONE OF A TURBOGENERATOR UNDER LOAD CONDITIONS
title_sort theoretical and harmonic analysis of magnetic fields in the active zone of a turbogenerator under load conditions
title_alt РАСЧЕТНЫЙ И ГАРМОНИЧЕСКИЙ АНАЛИЗ МАГНИТНЫХ ПОЛЕЙ В АКТИВНОЙ ЗОНЕ ТУРБОГЕНЕРАТОРА В РЕЖИМЕ НАГРУЗКИ
РАСЧЕТНЫЙ И ГАРМОНИЧЕСКИЙ АНАЛИЗ МАГНИТНЫХ ПОЛЕЙ В АКТИВНОЙ ЗОНЕ ТУРБОГЕНЕРАТОРА В РЕЖИМЕ НАГРУЗКИ
description The paper presents some principles and results of numerical field calculation and the corresponding harmonic analysis of magnetic field in the active zone of a large turbogenerator under load conditions. In addition to the traditional coordinate function of the magnetic induction, its time functions are considered at fixed points and at rotating rotor linked points in the gap. The stator magnetic flux linkage functions are also examined. It is revealed that these magnetic induction functions, which are different from sine curves, fail to provide the basis for determining time functions of magnetic flux linkage and the stator winding EMF that are close to sine waves.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2013
url http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.07
work_keys_str_mv AT milykhvi theoreticalandharmonicanalysisofmagneticfieldsintheactivezoneofaturbogeneratorunderloadconditions
AT polyakovanv theoreticalandharmonicanalysisofmagneticfieldsintheactivezoneofaturbogeneratorunderloadconditions
AT milykhvi rasčetnyjigarmoničeskijanalizmagnitnyhpolejvaktivnojzoneturbogeneratoravrežimenagruzki
AT polyakovanv rasčetnyjigarmoničeskijanalizmagnitnyhpolejvaktivnojzoneturbogeneratoravrežimenagruzki
first_indexed 2025-07-17T11:44:17Z
last_indexed 2025-12-02T15:30:49Z
_version_ 1850411004609953792