EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON

A technique and results of experimental studies of geomagnetic field (GMF) induction in 195 different rooms in educational institutions, residential buildings, shopping malls and subway are presented. It is shown that in all the buildings there is weakening of the natural GMF. However, the GMF weake...

Повний опис

Збережено в:
Бібліографічні деталі
Видавець:National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
Дата:2013
Автори: Rozov, V. Yu., Pelevin, D. Ye., Levina, S. V.
Формат: Стаття
Мова:Russian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2013
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.13
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!

Репозиторії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-19802
record_format ojs
spelling eiekhpieduua-article-198022024-06-01T14:35:15Z EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ЯВЛЕНИЯ ОСЛАБЛЕНИЯ СТАТИЧЕСКОГО ГЕОМАГНИТНОГО ПОЛЯ В ПОМЕЩЕНИЯХ ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ЯВЛЕНИЯ ОСЛАБЛЕНИЯ СТАТИЧЕСКОГО ГЕОМАГНИТНОГО ПОЛЯ В ПОМЕЩЕНИЯХ Rozov, V. Yu. Pelevin, D. Ye. Levina, S. V. static geomagnetic field steel building construction residential areas geomagnetic field weakening sanitary norms 621.3.013.22 613.168 статическое геомагнитное поле стальные элементы строительных конструкций жилые дома ослабление геомагнитного поля санитарные нормы 621.3.013.22 613.168 621.3.013.22 613.168 A technique and results of experimental studies of geomagnetic field (GMF) induction in 195 different rooms in educational institutions, residential buildings, shopping malls and subway are presented. It is shown that in all the buildings there is weakening of the natural GMF. However, the GMF weakening is slight in the most areas and not dangerous to public health. Exceptions are areas of high-rise frame-cast-in-place residential blocks, offices and premises of shopping centers with steel frames and platforms of underground stations. Here, the GMF can be weakened to a dangerous level (less than 25 µT), which requires measures for its normalization. Представлены методика и результаты экспериментальных исследований индукции геомагнитного поля (ГМП) в 195 различных помещениях учебных заведений, жилых домов, торгово-развлекательных центров, метрополитена. Показано, что во всех помещениях наблюдается явление ослабления естественного ГМП, однако в большинстве помещений ослабление ГМП незначительно и не представляет опасности для здоровья населения. Исключение составляют помещения высотных каркасно-монолитных жилых домов, помещения офисов и торгово-развлекательных центров со стальными каркасами, а также платформы подземных станций метрополитена, где ГМП может быть ослаблено до опасного уровня (менее 25 мкТл), что требует принятия мер по его нормализации. Представлені методика та результати експериментальних досліджень індукції геомагнітного поля (ГМП) в 195 різних приміщеннях навчальних закладів, житлових будинків, торговельно-розважальних центрів, метрополітену. Показано, що у всіх приміщеннях спостерігається явище ослаблення природного ГМП, проте в більшості приміщень ослаблення ГМП незначне і не представляє небезпеки для здоров'я населення. Виняток становлять приміщення висотних каркасно-монолітних житлових будинків, приміщення офісів і торгово-розважальних центрів зі сталевими каркасами, а також платформи підземних станцій метрополітену, де ГМП може бути ослаблене до небезпечного рівня (менше 25 мкТл), що вимагає вживання заходів щодо його нормалізації. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2013-12-29 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.13 10.20998/2074-272X.2013.6.13 Electrical Engineering & Electromechanics; No. 6 (2013); 72-76 Электротехника и Электромеханика; № 6 (2013); 72-76 Електротехніка і Електромеханіка; № 6 (2013); 72-76 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.13/17425 Copyright (c) 2015 V. Yu. Rozov, D. Ye. Pelevin, S. V. Levina https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
collection OJS
language Russian
topic static geomagnetic field
steel building construction
residential areas
geomagnetic field weakening
sanitary norms
621.3.013.22
613.168
статическое геомагнитное поле
стальные элементы строительных конструкций
жилые дома
ослабление геомагнитного поля
санитарные нормы
621.3.013.22
613.168
621.3.013.22
613.168
spellingShingle static geomagnetic field
steel building construction
residential areas
geomagnetic field weakening
sanitary norms
621.3.013.22
613.168
статическое геомагнитное поле
стальные элементы строительных конструкций
жилые дома
ослабление геомагнитного поля
санитарные нормы
621.3.013.22
613.168
621.3.013.22
613.168
Rozov, V. Yu.
Pelevin, D. Ye.
Levina, S. V.
EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
topic_facet static geomagnetic field
steel building construction
residential areas
geomagnetic field weakening
sanitary norms
621.3.013.22
613.168
статическое геомагнитное поле
стальные элементы строительных конструкций
жилые дома
ослабление геомагнитного поля
санитарные нормы
621.3.013.22
613.168
621.3.013.22
613.168
format Article
author Rozov, V. Yu.
Pelevin, D. Ye.
Levina, S. V.
author_facet Rozov, V. Yu.
Pelevin, D. Ye.
Levina, S. V.
author_sort Rozov, V. Yu.
title EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
title_short EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
title_full EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
title_fullStr EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
title_full_unstemmed EXPERIMENTAL RESEARCH INTO INDOOR STATIC GEOMAGNETIC FIELD WEAKENING PHENOMENON
title_sort experimental research into indoor static geomagnetic field weakening phenomenon
title_alt ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ЯВЛЕНИЯ ОСЛАБЛЕНИЯ СТАТИЧЕСКОГО ГЕОМАГНИТНОГО ПОЛЯ В ПОМЕЩЕНИЯХ
ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ЯВЛЕНИЯ ОСЛАБЛЕНИЯ СТАТИЧЕСКОГО ГЕОМАГНИТНОГО ПОЛЯ В ПОМЕЩЕНИЯХ
description A technique and results of experimental studies of geomagnetic field (GMF) induction in 195 different rooms in educational institutions, residential buildings, shopping malls and subway are presented. It is shown that in all the buildings there is weakening of the natural GMF. However, the GMF weakening is slight in the most areas and not dangerous to public health. Exceptions are areas of high-rise frame-cast-in-place residential blocks, offices and premises of shopping centers with steel frames and platforms of underground stations. Here, the GMF can be weakened to a dangerous level (less than 25 µT), which requires measures for its normalization.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2013
url http://eie.khpi.edu.ua/article/view/2074-272X.2013.6.13
work_keys_str_mv AT rozovvyu experimentalresearchintoindoorstaticgeomagneticfieldweakeningphenomenon
AT pelevindye experimentalresearchintoindoorstaticgeomagneticfieldweakeningphenomenon
AT levinasv experimentalresearchintoindoorstaticgeomagneticfieldweakeningphenomenon
AT rozovvyu éksperimentalʹnyeissledovaniââvleniâoslableniâstatičeskogogeomagnitnogopolâvpomeŝeniâh
AT pelevindye éksperimentalʹnyeissledovaniââvleniâoslableniâstatičeskogogeomagnitnogopolâvpomeŝeniâh
AT levinasv éksperimentalʹnyeissledovaniââvleniâoslableniâstatičeskogogeomagnitnogopolâvpomeŝeniâh
first_indexed 2024-06-01T14:37:31Z
last_indexed 2024-06-01T14:37:31Z
_version_ 1800669916810969088