SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES

Wind turbines with permanent magnet synchronous generator (PMSG) are widely used as sources of energy connected to a grid. The studied system is composed of a wind turbine based on PMSG, a bridge rectifier, a boost converter, and a controlled inverter to eliminate low-order harmonics in grid current...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2020
Автори: Boukhechem, I., Boukadoum, A., Boukelkoul, L., Lebied, R.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2020
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2020.3.08
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-206167
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2020-06-25T09:02:14Z
collection OJS
language English
topic direct power control based virtual flux
disturbances of grid voltage
permanent magnet synchronous generator
621.3
spellingShingle direct power control based virtual flux
disturbances of grid voltage
permanent magnet synchronous generator
621.3
Boukhechem, I.
Boukadoum, A.
Boukelkoul, L.
Lebied, R.
SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
topic_facet direct power control based virtual flux
disturbances of grid voltage
permanent magnet synchronous generator
621.3
виртуальный поток на основе прямого управления мощностью
возмущения напряжения сети
синхронный генератор с постоянными магнитами
621.3
format Article
author Boukhechem, I.
Boukadoum, A.
Boukelkoul, L.
Lebied, R.
author_facet Boukhechem, I.
Boukadoum, A.
Boukelkoul, L.
Lebied, R.
author_sort Boukhechem, I.
title SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
title_short SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
title_full SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
title_fullStr SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
title_full_unstemmed SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
title_sort sensorless direct power control for three-phase grid side converter integrated into wind turbine system under disturbed grid voltages
title_alt SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES
description Wind turbines with permanent magnet synchronous generator (PMSG) are widely used as sources of energy connected to a grid. The studied system is composed of a wind turbine based on PMSG, a bridge rectifier, a boost converter, and a controlled inverter to eliminate low-order harmonics in grid currents under disturbances of grid voltage. Traditionally, the grid side converter is controlled by using the control VFOC (Virtual Flux Oriented Control), which decouple the three-phase currents indirect components (id) and in quadratic (iq) and regulate them separately. However, the VFOC approach is dependent on the parameters of the system. This paper illustrates a new scheme for the grid-connected converter controller. Voltage imbalance and harmonic contents in the three-phase voltage system cause current distortions. Hence, the synchronization with the network is an important feature of controlling the voltage converter. Thus, a robust control method is necessary to maintain the adequate injection of the power during faults and/or a highly distorted grid voltage. The proposed new control strategy is to use the direct power control based virtual flux to eliminate side effects induced by mains disturbances. This control technique lowers remarkably the fluctuations of the active and reactive power and the harmonic distortion rate. The estimated powers used in the proposed control approach is calculated directly by the positive, negative, and harmonic items of the estimated flux and the measured current without line sensor voltage.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2020
url http://eie.khpi.edu.ua/article/view/2074-272X.2020.3.08
work_keys_str_mv AT boukhechemi sensorlessdirectpowercontrolforthreephasegridsideconverterintegratedintowindturbinesystemunderdisturbedgridvoltages
AT boukadouma sensorlessdirectpowercontrolforthreephasegridsideconverterintegratedintowindturbinesystemunderdisturbedgridvoltages
AT boukelkoull sensorlessdirectpowercontrolforthreephasegridsideconverterintegratedintowindturbinesystemunderdisturbedgridvoltages
AT lebiedr sensorlessdirectpowercontrolforthreephasegridsideconverterintegratedintowindturbinesystemunderdisturbedgridvoltages
first_indexed 2025-07-17T11:48:06Z
last_indexed 2025-07-17T11:48:06Z
_version_ 1850411909037162496
spelling eiekhpieduua-article-2061672020-06-25T09:02:14Z SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES SENSORLESS DIRECT POWER CONTROL FOR THREE-PHASE GRID SIDE CONVERTER INTEGRATED INTO WIND TURBINE SYSTEM UNDER DISTURBED GRID VOLTAGES Boukhechem, I. Boukadoum, A. Boukelkoul, L. Lebied, R. direct power control based virtual flux disturbances of grid voltage permanent magnet synchronous generator 621.3 виртуальный поток на основе прямого управления мощностью возмущения напряжения сети синхронный генератор с постоянными магнитами 621.3 Wind turbines with permanent magnet synchronous generator (PMSG) are widely used as sources of energy connected to a grid. The studied system is composed of a wind turbine based on PMSG, a bridge rectifier, a boost converter, and a controlled inverter to eliminate low-order harmonics in grid currents under disturbances of grid voltage. Traditionally, the grid side converter is controlled by using the control VFOC (Virtual Flux Oriented Control), which decouple the three-phase currents indirect components (id) and in quadratic (iq) and regulate them separately. However, the VFOC approach is dependent on the parameters of the system. This paper illustrates a new scheme for the grid-connected converter controller. Voltage imbalance and harmonic contents in the three-phase voltage system cause current distortions. Hence, the synchronization with the network is an important feature of controlling the voltage converter. Thus, a robust control method is necessary to maintain the adequate injection of the power during faults and/or a highly distorted grid voltage. The proposed new control strategy is to use the direct power control based virtual flux to eliminate side effects induced by mains disturbances. This control technique lowers remarkably the fluctuations of the active and reactive power and the harmonic distortion rate. The estimated powers used in the proposed control approach is calculated directly by the positive, negative, and harmonic items of the estimated flux and the measured current without line sensor voltage. Ветряные турбины с синхронным генератором на постоянных магнитах (PMSG) широко используются в качестве источников энергии, подключенных к сети. Исследуемая система состоит из ветряной турбины на основе PMSG, мостового выпрямителя, повышающего преобразователя и управляемого инвертора для устранения гармоник низкого порядка в токах сетки при возмущениях напряжения сети. Традиционно преобразователь на стороне сети управляется с помощью виртуального потокоориентированного управления VFOC (Virtual Flux Oriented Control), который разделяет трехфазные токи на косвенные компоненты (id) и на квадратичные компоннеты (iq) и регулирует их отдельно. Однако подход VFOC зависит от параметров системы. Данная статья иллюстрирует новую схему для контроллера преобразователя, подключенного к сети. Дисбаланс напряжения и содержание гармоник в трехфазной системе напряжения вызывают искажения тока. Следовательно, синхронизация с сетью является важной особенностью управления преобразователем напряжения. Таким образом, надежный метод управления необходим для поддержания адекватной подачи энергии во время неисправностей и/или значительно искаженного напряжения сети. Предложенная новая стратегия управления заключается в использовании виртуального потока на основе прямого управления мощностью для устранения побочных эффектов, вызванных помехами в сети. Этот метод управления значительно снижает колебания активной и реактивной мощности и уровень гармонических искажений. Оценочные мощности, используемые в предлагаемом подходе к управлению, рассчитываются непосредственно по положительным, отрицательным и гармоническим элементам оцененного потока и измеренного тока без напряжения линейного датчика. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2020-06-25 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2020.3.08 10.20998/2074-272X.2020.3.08 Electrical Engineering & Electromechanics; No. 3 (2020); 48-57 Электротехника и Электромеханика; № 3 (2020); 48-57 Електротехніка і Електромеханіка; № 3 (2020); 48-57 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/2074-272X.2020.3.08/206289 Copyright (c) 2020 I. Boukhechem, A. Boukadoum, L. Boukelkoul, R. Lebied https://creativecommons.org/licenses/by-nc/4.0