ANALYSIS OF ELECTRICITY CONSUMPTION OF INDUCTION MOTORS OF IE1 AND IE2 EFFICIENCY CLASSES IN A 11 kW PUMP INSTALLATION
Purpose. Comparative analysis of energy consumption indicators of electric motors of different energy efficiency classes in an electric drive of a centrifugal pump with power of 11 kW of a water supply system with throttle regulation. Methodology. In this paper a comparison of energy consumption of...