ANALYSIS OF ELECTRICITY CONSUMPTION OF INDUCTION MOTORS OF IE1 AND IE2 EFFICIENCY CLASSES IN A 11 kW PUMP INSTALLATION

Purpose. Comparative analysis of energy consumption indicators of electric motors of different energy efficiency classes in an electric drive of a centrifugal pump with power of 11 kW of a water supply system with throttle regulation. Methodology. In this paper a comparison of energy consumption of...

Full description

Saved in:
Bibliographic Details
Date:2020
Main Authors: Oshurbekov, S. Kh., Kazakbaev, V. M., Prakht, V. A., Dmitrievskii, V. A., Paramonov, A. S.
Format: Article
Language:English
Ukrainian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2020
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2020.5.03
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics

Similar Items