Energy-efficient induction motors designing with application of a modified criterion of reduced costs

The paper introduces a modified criterion of reduced costs that employs coefficients of operation significance and priority of ohmic loss accounting to allow matching maximum efficiency with minimum reduced costs. Impact of the inflation factor on the criterion of reduced costs is analyzed.

Gespeichert in:
Bibliographische Detailangaben
Datum:2014
1. Verfasser: Petrushin, V. S.
Format: Artikel
Sprache:Russian
Veröffentlicht: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014
Schlagworte:
Online Zugang:http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.05
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
Beschreibung
Zusammenfassung:The paper introduces a modified criterion of reduced costs that employs coefficients of operation significance and priority of ohmic loss accounting to allow matching maximum efficiency with minimum reduced costs. Impact of the inflation factor on the criterion of reduced costs is analyzed.