CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are g...
Збережено в:
Дата: | 2014 |
---|---|
Автор: | |
Формат: | Стаття |
Мова: | Russian |
Опубліковано: |
National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
2014
|
Теми: | |
Онлайн доступ: | http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Electrical Engineering & Electromechanics |
Репозитарії
Electrical Engineering & Electromechanicsid |
eiekhpieduua-article-22462 |
---|---|
record_format |
ojs |
spelling |
eiekhpieduua-article-224622024-06-01T14:35:16Z CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ Sirotin, Iu. A. three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given. Рассмотрена задача компенсации неактивной мощности в трехпроводной трехфазной сети с несимметричным синусоидальным напряжением. Предложен алгоритм вычисления реактивных проводимостей Δ-компенсатора по составляющей полного тока, активная мощность которой равна нулю. Рассмотрены примеры расчетов. Розглянуто задачу компенсації неактивної потужності у трипровідній трифазній мережі з несиметричною синусоїдальною напругою. Запропоновано алгоритм обчислення реактивних провідностей Δ-компенсатора за складовою повного струму, активна потужність якої дорівнює нулю. Розглянуто приклади розрахунків. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2014-03-04 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13 10.20998/2074-272X.2014.1.13 Electrical Engineering & Electromechanics; No. 1 (2014); 71-74 Электротехника и Электромеханика; № 1 (2014); 71-74 Електротехніка і Електромеханіка; № 1 (2014); 71-74 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13/20079 Copyright (c) 2015 Iu. A. Sirotin https://creativecommons.org/licenses/by-nc/4.0 |
institution |
Electrical Engineering & Electromechanics |
collection |
OJS |
language |
Russian |
topic |
three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 |
spellingShingle |
three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 Sirotin, Iu. A. CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
topic_facet |
three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 |
format |
Article |
author |
Sirotin, Iu. A. |
author_facet |
Sirotin, Iu. A. |
author_sort |
Sirotin, Iu. A. |
title |
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
title_short |
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
title_full |
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
title_fullStr |
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
title_full_unstemmed |
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET |
title_sort |
calculation of compensating susceptance for a three-wire net |
title_alt |
РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ |
description |
A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given. |
publisher |
National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” |
publishDate |
2014 |
url |
http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13 |
work_keys_str_mv |
AT sirotiniua calculationofcompensatingsusceptanceforathreewirenet AT sirotiniua rasčetreaktivnyhprovodimostejkompensatoradlâtrehprovodnojseti |
first_indexed |
2024-06-01T14:37:35Z |
last_indexed |
2024-06-01T14:37:35Z |
_version_ |
1800669921196113920 |