CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET

A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are g...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2014
Автор: Sirotin, Iu. A.
Формат: Стаття
Мова:Russian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2014
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-22462
record_format ojs
spelling eiekhpieduua-article-224622024-06-01T14:35:16Z CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ Sirotin, Iu. A. three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 three-phase network compensation asymmetrical voltage reactive power 621.31 A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given. Рассмотрена задача компенсации неактивной мощности в трехпроводной трехфазной сети с несимметричным синусоидальным напряжением. Предложен алгоритм вычисления реактивных проводимостей Δ-компенсатора по составляющей полного тока, активная мощность которой равна нулю. Рассмотрены примеры расчетов. Розглянуто задачу компенсації неактивної потужності у трипровідній трифазній мережі з несиметричною синусоїдальною напругою. Запропоновано алгоритм обчислення реактивних провідностей Δ-компенсатора за складовою повного струму, активна потужність якої дорівнює нулю. Розглянуто приклади розрахунків. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2014-03-04 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13 10.20998/2074-272X.2014.1.13 Electrical Engineering & Electromechanics; No. 1 (2014); 71-74 Электротехника и Электромеханика; № 1 (2014); 71-74 Електротехніка і Електромеханіка; № 1 (2014); 71-74 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13/20079 Copyright (c) 2015 Iu. A. Sirotin https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
collection OJS
language Russian
topic three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
spellingShingle three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
Sirotin, Iu. A.
CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
topic_facet three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
three-phase network
compensation
asymmetrical voltage
reactive power
621.31
format Article
author Sirotin, Iu. A.
author_facet Sirotin, Iu. A.
author_sort Sirotin, Iu. A.
title CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
title_short CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
title_full CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
title_fullStr CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
title_full_unstemmed CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
title_sort calculation of compensating susceptance for a three-wire net
title_alt РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ
РАСЧЕТ РЕАКТИВНЫХ ПРОВОДИМОСТЕЙ КОМПЕНСАТОРА ДЛЯ ТРЕХПРОВОДНОЙ СЕТИ
description A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2014
url http://eie.khpi.edu.ua/article/view/2074-272X.2014.1.13
work_keys_str_mv AT sirotiniua calculationofcompensatingsusceptanceforathreewirenet
AT sirotiniua rasčetreaktivnyhprovodimostejkompensatoradlâtrehprovodnojseti
first_indexed 2024-06-01T14:37:35Z
last_indexed 2024-06-01T14:37:35Z
_version_ 1800669921196113920