Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks

Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conduc...

Full description

Saved in:
Bibliographic Details
Date:2021
Main Authors: Bezprozvannych, G.V., Kostiukov, I.A., Pushkar, O.A.
Format: Article
Language:English
Ukrainian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2021
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/225161
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-225161
record_format ojs
spelling eiekhpieduua-article-2251612021-02-23T09:10:20Z Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks Синтез конструктивно-технологічних рішень регулювання робочої ємності кабелів промислових мереж Bezprozvannych, G.V. Kostiukov, I.A. Pushkar, O.A. industrial networks twisted pair insulated conductor foaming insulation thickness effective dielectric constant electrical capacitance промислові мережі вита пара ізольований провідник спінення товщина ізоляції ефективна діелектрична проникність електрична ємність Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %. Доведено більшу чутливість регулювання технологічного процесу виготовлення ізольованого провідника витої пари при охолодженні у воді в порівнянні з повітряним. При зміненні товщини ізоляції в 4 рази електрична ємність ізольованого провідника змінюється більше, ніж в 2 рази, та на 5 % при знаходженні у воді та повітрі відповідно. Ефективне регулювання забезпечується на підставі отриманих залежностей ефективної діелектричної проникності, тангенсу кута діелектричних втрат та ємності ізольованого провідника від ступеню спінення та товщини захисної плівки двошарової ізоляції. При ступені пористості 40 % діелектрична проникність зменшується на 25 %, тангенс кута діелектричних втрат – на 33 %, електрична ємність ізольованого провідника – на 20 %. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2021-02-23 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/225161 10.20998/2074-272X.2021.1.07 Electrical Engineering & Electromechanics; No. 1 (2021); 44-49 Электротехника и Электромеханика; № 1 (2021); 44-49 Електротехніка і Електромеханіка; № 1 (2021); 44-49 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/225161/225157 http://eie.khpi.edu.ua/article/view/225161/225158 Copyright (c) 2021 G.V. Bezprozvannych, I.A. Kostiukov, O.A. Pushkar http://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2021-02-23T09:10:20Z
collection OJS
language English
Ukrainian
topic industrial networks
twisted pair
insulated conductor
foaming
insulation thickness
effective dielectric constant
electrical capacitance
spellingShingle industrial networks
twisted pair
insulated conductor
foaming
insulation thickness
effective dielectric constant
electrical capacitance
Bezprozvannych, G.V.
Kostiukov, I.A.
Pushkar, O.A.
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
topic_facet industrial networks
twisted pair
insulated conductor
foaming
insulation thickness
effective dielectric constant
electrical capacitance
промислові мережі
вита пара
ізольований провідник
спінення
товщина ізоляції
ефективна діелектрична проникність
електрична ємність
format Article
author Bezprozvannych, G.V.
Kostiukov, I.A.
Pushkar, O.A.
author_facet Bezprozvannych, G.V.
Kostiukov, I.A.
Pushkar, O.A.
author_sort Bezprozvannych, G.V.
title Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_short Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_full Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_fullStr Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_full_unstemmed Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_sort synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_alt Синтез конструктивно-технологічних рішень регулювання робочої ємності кабелів промислових мереж
description Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2021
url http://eie.khpi.edu.ua/article/view/225161
work_keys_str_mv AT bezprozvannychgv synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
AT kostiukovia synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
AT pushkaroa synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
AT bezprozvannychgv sintezkonstruktivnotehnologíčnihríšenʹregulûvannârobočoíêmnostíkabelívpromislovihmerež
AT kostiukovia sintezkonstruktivnotehnologíčnihríšenʹregulûvannârobočoíêmnostíkabelívpromislovihmerež
AT pushkaroa sintezkonstruktivnotehnologíčnihríšenʹregulûvannârobočoíêmnostíkabelívpromislovihmerež
first_indexed 2025-07-17T11:48:22Z
last_indexed 2025-07-17T11:48:22Z
_version_ 1850411948530728960