Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study

Introduction. Nowadays, power transformer aging and failures are viewed with great attention in power transmission industry. Dissolved gas analysis (DGA) is classified among the biggest widely used methods used within the context of asset management policy to detect the incipient faults in their ear...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2021
Автори: Bouchaoui, L., Hemsas, K. E., Mellah, H., Benlahneche, S.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2021
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/237786
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-237786
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
topic analysis of dissolved gases in oil
diagnostics of power transformers
feed-forward neural networks
Rogers method
IEC method
аналіз розчинених газів у маслі
діагностика силових трансформаторів
нейронні мережі зі зворотним зв'язком
метод Роджерса
метод МЕК
spellingShingle analysis of dissolved gases in oil
diagnostics of power transformers
feed-forward neural networks
Rogers method
IEC method
аналіз розчинених газів у маслі
діагностика силових трансформаторів
нейронні мережі зі зворотним зв'язком
метод Роджерса
метод МЕК
Bouchaoui, L.
Hemsas, K. E.
Mellah, H.
Benlahneche, S.
Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
topic_facet analysis of dissolved gases in oil
diagnostics of power transformers
feed-forward neural networks
Rogers method
IEC method
аналіз розчинених газів у маслі
діагностика силових трансформаторів
нейронні мережі зі зворотним зв'язком
метод Роджерса
метод МЕК
format Article
author Bouchaoui, L.
Hemsas, K. E.
Mellah, H.
Benlahneche, S.
author_facet Bouchaoui, L.
Hemsas, K. E.
Mellah, H.
Benlahneche, S.
author_sort Bouchaoui, L.
title Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
title_short Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
title_full Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
title_fullStr Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
title_full_unstemmed Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
title_sort power transformer faults diagnosis using undestructive methods (roger and iec) and artificial neural network for dissolved gas analysis applied on the functional transformer in the algerian north-eastern: a comparative study
title_alt Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study
description Introduction. Nowadays, power transformer aging and failures are viewed with great attention in power transmission industry. Dissolved gas analysis (DGA) is classified among the biggest widely used methods used within the context of asset management policy to detect the incipient faults in their earlier stage in power transformers. Up to now, several procedures have been employed for the lecture of DGA results. Among these useful means, we find Key Gases, Rogers Ratios, IEC Ratios, the historical technique less used today Doernenburg Ratios, the two types of Duval Pentagons methods, several versions of the Duval Triangles method and Logarithmic Nomograph. Problem. DGA data extracted from different units in service served to verify the ability and reliability of these methods in assessing the state of health of the power transformer. Aim. An improving the quality of diagnostics of electrical power transformer by artificial neural network tools based on two conventional methods in the case of a functional power transformer at Sétif province in East North of Algeria. Methodology. Design an inelegant tool for power transformer diagnosis using neural networks based on traditional methods IEC and Rogers, which allows to early detection faults, to increase the reliability, of the entire electrical energy system from transport to consumers and improve a continuity and quality of service. Results. The solution of the problem was carried out by using feed-forward back-propagation neural networks implemented in MATLAB-Simulink environment. Four real power transformers working under different environment and climate conditions such as: desert, humid, cold were taken into account. The practical results of the diagnosis of these power transformers by the DGA are presented. Practical value. The structure and specific features of power transformer winding insulation ageing and defect state diagnosis by the application of the artificial neural network (ANN) has been briefly given. MATLAB programs were then developed to automate the evaluation of each method. This paper presents another tool to review the results obtained by the delta X software widely used by the electricity company in Algeria.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2021
url http://eie.khpi.edu.ua/article/view/237786
work_keys_str_mv AT bouchaouil powertransformerfaultsdiagnosisusingundestructivemethodsrogerandiecandartificialneuralnetworkfordissolvedgasanalysisappliedonthefunctionaltransformerinthealgeriannortheasternacomparativestudy
AT hemsaske powertransformerfaultsdiagnosisusingundestructivemethodsrogerandiecandartificialneuralnetworkfordissolvedgasanalysisappliedonthefunctionaltransformerinthealgeriannortheasternacomparativestudy
AT mellahh powertransformerfaultsdiagnosisusingundestructivemethodsrogerandiecandartificialneuralnetworkfordissolvedgasanalysisappliedonthefunctionaltransformerinthealgeriannortheasternacomparativestudy
AT benlahneches powertransformerfaultsdiagnosisusingundestructivemethodsrogerandiecandartificialneuralnetworkfordissolvedgasanalysisappliedonthefunctionaltransformerinthealgeriannortheasternacomparativestudy
first_indexed 2024-06-01T14:39:54Z
last_indexed 2024-06-01T14:39:54Z
_version_ 1800670066247729152
spelling eiekhpieduua-article-2377862021-07-29T04:36:40Z Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study Power transformer faults diagnosis using undestructive methods (Roger and IEC) and artificial neural network for dissolved gas analysis applied on the functional transformer in the Algerian north-eastern: a comparative study Bouchaoui, L. Hemsas, K. E. Mellah, H. Benlahneche, S. analysis of dissolved gases in oil diagnostics of power transformers feed-forward neural networks Rogers method IEC method аналіз розчинених газів у маслі діагностика силових трансформаторів нейронні мережі зі зворотним зв'язком метод Роджерса метод МЕК Introduction. Nowadays, power transformer aging and failures are viewed with great attention in power transmission industry. Dissolved gas analysis (DGA) is classified among the biggest widely used methods used within the context of asset management policy to detect the incipient faults in their earlier stage in power transformers. Up to now, several procedures have been employed for the lecture of DGA results. Among these useful means, we find Key Gases, Rogers Ratios, IEC Ratios, the historical technique less used today Doernenburg Ratios, the two types of Duval Pentagons methods, several versions of the Duval Triangles method and Logarithmic Nomograph. Problem. DGA data extracted from different units in service served to verify the ability and reliability of these methods in assessing the state of health of the power transformer. Aim. An improving the quality of diagnostics of electrical power transformer by artificial neural network tools based on two conventional methods in the case of a functional power transformer at Sétif province in East North of Algeria. Methodology. Design an inelegant tool for power transformer diagnosis using neural networks based on traditional methods IEC and Rogers, which allows to early detection faults, to increase the reliability, of the entire electrical energy system from transport to consumers and improve a continuity and quality of service. Results. The solution of the problem was carried out by using feed-forward back-propagation neural networks implemented in MATLAB-Simulink environment. Four real power transformers working under different environment and climate conditions such as: desert, humid, cold were taken into account. The practical results of the diagnosis of these power transformers by the DGA are presented. Practical value. The structure and specific features of power transformer winding insulation ageing and defect state diagnosis by the application of the artificial neural network (ANN) has been briefly given. MATLAB programs were then developed to automate the evaluation of each method. This paper presents another tool to review the results obtained by the delta X software widely used by the electricity company in Algeria. Вступ. У наш час старіння та несправності силових трансформаторів уважно розглядаються у галузі передачі електричної енергії. Аналіз розчиненого газу  виділяється серед найбільш широко використовуваних методів, що застосовуються в контексті політики управління активами для виявлення початкових несправностей на їх попередній стадії в силових трансформаторах. Дотепер для отримання результатів аналізу розчиненого газу було використано кілька процедур. Серед цих корисних засобів зазначимо такі, як метод основних газів, коефіцієнти Роджерса, коефіцієнти МЕК, історичний підхід, менш використовувані сьогодні коефіцієнти Дерненбурга, два типи методів п’ятикутників Дюваля, кілька варіантів методу трикутників Дюваля та логарифмічний номограф. Проблема. Дані аналізу розчиненого газу, отримані з різних об‘єктів, що експлуатуються, слугували для перевірки здатності та надійності цих методів при оцінці стану працездатності силового трансформатора. Мета. Підвищення якості діагностики електричного силового трансформатора за допомогою штучних нейромережевих інструментів, заснованих на двох звичайних методах, у випадку функціонуючого силового трансформатора в провінції Сетіф на північному сході Алжиру. Методологія. Розробка нетипового засобу для діагностики силових трансформаторів з використанням нейронних мереж на основі традиційних методів МЕК і Роджерса, який дозволяє раннє виявлення несправностей, підвищення надійності всієї електроенергетичної системи від передачі енергії до споживачів та покращення безперервності та якості обслуговування. Результати. Розв‘язання проблеми було здійснено за допомогою нейронних мереж зворотного розповсюдження із зворотним зв'язком, реалізованих в середовищі MATLAB-Simulink. Були враховані чотири діючі силові трансформатори, що працюють в різних умовах оточуючого середовища та клімату, таких як: пустеля, волога, холод. Представлені практичні результати діагностики цих силових трансформаторів з використанням аналізу розчиненого газу. Практичне значення. Стисло наведено структуру та специфічні особливості старіння ізоляції обмоток силових трансформаторів та діагностики стану дефектів за допомогою штучної нейронної мережі. Далі були розроблені програми у MATLAB для автоматизації оцінки кожного методу. Ця стаття представляє ще один засіб для аналізу результатів, отриманих за допомогою програмного забезпечення delta X, що широко використовується електричною компанією в Алжирі. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2021-07-29 Article Article application/pdf http://eie.khpi.edu.ua/article/view/237786 10.20998/2074-272X.2021.4.01 Electrical Engineering & Electromechanics; No. 4 (2021); 3-11 Электротехника и Электромеханика; № 4 (2021); 3-11 Електротехніка і Електромеханіка; № 4 (2021); 3-11 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/237786/236477 Copyright (c) 2021 L. Bouchaoui, K. E. Hemsas, H. Mellah, S. Benlahneche http://creativecommons.org/licenses/by-nc/4.0