Modelling and performance testing of a digital over-current relay enhanced designed model

Introduction. The over-current relay is widely used to protect distribution and transmission electrical systems against excessive currents occurring due to short circuit or overload conditions. Many works have been carried out in the field of models simulation design of digital over-current relays i...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2022
Автори: Sekhane, H., Labed, D., Labed, M. A.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/252304
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-252304
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
topic digital over-current relay
inverse and instantaneous characteristics
load starting current
primary protection
back-up protection
цифрове реле надструму
зворотні та миттєві характеристики
пусковий струм навантаження
первинний захист
резервний захист
spellingShingle digital over-current relay
inverse and instantaneous characteristics
load starting current
primary protection
back-up protection
цифрове реле надструму
зворотні та миттєві характеристики
пусковий струм навантаження
первинний захист
резервний захист
Sekhane, H.
Labed, D.
Labed, M. A.
Modelling and performance testing of a digital over-current relay enhanced designed model
topic_facet digital over-current relay
inverse and instantaneous characteristics
load starting current
primary protection
back-up protection
цифрове реле надструму
зворотні та миттєві характеристики
пусковий струм навантаження
первинний захист
резервний захист
format Article
author Sekhane, H.
Labed, D.
Labed, M. A.
author_facet Sekhane, H.
Labed, D.
Labed, M. A.
author_sort Sekhane, H.
title Modelling and performance testing of a digital over-current relay enhanced designed model
title_short Modelling and performance testing of a digital over-current relay enhanced designed model
title_full Modelling and performance testing of a digital over-current relay enhanced designed model
title_fullStr Modelling and performance testing of a digital over-current relay enhanced designed model
title_full_unstemmed Modelling and performance testing of a digital over-current relay enhanced designed model
title_sort modelling and performance testing of a digital over-current relay enhanced designed model
title_alt Modelling and performance testing of a digital over-current relay enhanced designed model
description Introduction. The over-current relay is widely used to protect distribution and transmission electrical systems against excessive currents occurring due to short circuit or overload conditions. Many works have been carried out in the field of models simulation design of digital over-current relays in the literature, but unfortunately many of them are more complex design models, have very slow execution time and only work in simple faults cases. Purpose. The purpose of this work is to present the performance of a modified and improved model of a digital over-current relay designed in Simulink/MATLAB environment with more simplified design, faster execution time, and able to operate under more complex fault conditions. Methodology. Before starting tests, modelling of over-current relay is presented in details, of which the basic logics of the proposed model to implement inverse and instantaneous characteristics are well explained. Afterwards, various tests are carried out for the performance analysis of the enhanced designed relay model in terms of: operating speed for eliminating faults that has arisen, ability to distinguish between a fault current and load starting current, capacity distinguish between real and temporary fault currents, the way to manage variable faults over time, and the degree of harmony between primary protection relay and back-up protection relay. Originality. The originality of our proposed work consists in the development and improvement of a digital over-current relay model designed in Simulink/MATLAB environment in such way that it becomes able to operate under new harsh test conditions. This developed designed model is implemented and applied in a 400V radial distribution power system with a load that causes a starting current. Results. The obtained values of simulation are compared with the theoretically calculated values and known existing models. The obtained results after various tests validate the good performance of our enhanced designed model.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2022
url http://eie.khpi.edu.ua/article/view/252304
work_keys_str_mv AT sekhaneh modellingandperformancetestingofadigitalovercurrentrelayenhanceddesignedmodel
AT labedd modellingandperformancetestingofadigitalovercurrentrelayenhanceddesignedmodel
AT labedma modellingandperformancetestingofadigitalovercurrentrelayenhanceddesignedmodel
first_indexed 2024-06-01T14:40:02Z
last_indexed 2024-06-01T14:40:02Z
_version_ 1800670075391311872
spelling eiekhpieduua-article-2523042022-05-30T16:52:46Z Modelling and performance testing of a digital over-current relay enhanced designed model Modelling and performance testing of a digital over-current relay enhanced designed model Sekhane, H. Labed, D. Labed, M. A. digital over-current relay inverse and instantaneous characteristics load starting current primary protection back-up protection цифрове реле надструму зворотні та миттєві характеристики пусковий струм навантаження первинний захист резервний захист Introduction. The over-current relay is widely used to protect distribution and transmission electrical systems against excessive currents occurring due to short circuit or overload conditions. Many works have been carried out in the field of models simulation design of digital over-current relays in the literature, but unfortunately many of them are more complex design models, have very slow execution time and only work in simple faults cases. Purpose. The purpose of this work is to present the performance of a modified and improved model of a digital over-current relay designed in Simulink/MATLAB environment with more simplified design, faster execution time, and able to operate under more complex fault conditions. Methodology. Before starting tests, modelling of over-current relay is presented in details, of which the basic logics of the proposed model to implement inverse and instantaneous characteristics are well explained. Afterwards, various tests are carried out for the performance analysis of the enhanced designed relay model in terms of: operating speed for eliminating faults that has arisen, ability to distinguish between a fault current and load starting current, capacity distinguish between real and temporary fault currents, the way to manage variable faults over time, and the degree of harmony between primary protection relay and back-up protection relay. Originality. The originality of our proposed work consists in the development and improvement of a digital over-current relay model designed in Simulink/MATLAB environment in such way that it becomes able to operate under new harsh test conditions. This developed designed model is implemented and applied in a 400V radial distribution power system with a load that causes a starting current. Results. The obtained values of simulation are compared with the theoretically calculated values and known existing models. The obtained results after various tests validate the good performance of our enhanced designed model. Вступ. Реле надструму широко використовується для захисту електричних систем розподілу та передачі від надмірних струмів, що виникають внаслідок короткого замикання або перевантаження. У літературі було виконано багато робіт у галузі моделювання цифрового реле надструму, але, на жаль, багато з них є більш складними моделями конструкції, з дуже повільним часом виконання, і вони працюють лише у випадках простих несправностей. Метою даної роботи є представлення продуктивності модифікованої та вдосконаленої моделі цифрового реле надструму, розробленої в середовищі Simulink/MATLAB, з більш спрощеною конструкцією, швидшим часом виконання та здатністю працювати в більш складних умовах несправностей. Методологія. Перед початком випробувань детально представлено моделювання реле надструму, з якої добре пояснено основні логіки запропонованої моделі для реалізації зворотних і миттєвих характеристик. Після цього проводяться різноманітні випробування для аналізу продуктивності вдосконаленої розробленої моделі реле з точки зору: швидкості роботи для усунення виниклих несправностей, здатності розрізняти струм несправності та пусковий струм навантаження, можливості розрізняти реальні та тимчасові струми несправності, спосіб управління змінними несправностями в часі та ступінь відповідності реле первинного захисту та реле резервного захисту. Оригінальність запропонованої нами роботи полягає в розробці та вдосконаленні моделі цифрового реле надструму, розробленої в середовищі Simulink/MATLAB таким чином, щоб вона стала здатною працювати в нових жорстких умовах випробувань. Ця розроблена модель реалізована та застосована у радіальної розподільчої енергосистемі 400 В з навантаженням, що викликає пусковий струм. Результати. Отримані результати моделювання порівнюються з теоретично розрахованими значеннями. Результати, отримані після різноманітних випробувань, підтверджують хорошу продуктивність нашої покращеної розробленої моделі. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022-05-30 Article Article application/pdf http://eie.khpi.edu.ua/article/view/252304 10.20998/2074-272X.2022.3.10 Electrical Engineering & Electromechanics; No. 3 (2022); 71-78 Электротехника и Электромеханика; № 3 (2022); 71-78 Електротехніка і Електромеханіка; № 3 (2022); 71-78 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/252304/254605 Copyright (c) 2022 H. Sekhane, D. Labed, M. A. Labed http://creativecommons.org/licenses/by-nc/4.0