Method of adjustment of three circuit system of active shielding of magnetic field in multi-storey buildings from overhead power lines with wires triangular arrangement

Aim. For the first time the method of adjustment of three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines w...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2022
Автори: Kuznetsov, B. I., Nikitina, T. B., Bovdui, I. V., Voloshko, O. V., Kolomiets, V. V., Kobylianskiy, B. B.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2022
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/252815
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
Опис
Резюме:Aim. For the first time the method of adjustment of three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines with a wires triangular arrangement was developed. Methodology. When synthesizing the laboratory model of system of active shielding the coordinates of spatial arrangement and of three shielding coils, the currents in shielding coils and resulting magnetic flux density value in the shielding space were calculated. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is calculated based on the stochastic particles multi swarm optimization algorithms. Results. Computer simulation and experimental research of the space-time characteristics of laboratory model of three circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing to the sanitary standards level is shown. Originality. For the first time the synthesis and adjustment of laboratory model of three circuit system of active shielding of magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines with a wires triangular arrangement carried out. Practical value. Practical recommendations from the point of view of the implementation of developed method of adjustment of the three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics in a multi-storey building located near a single-circuit overhead transmission lines with a triangular arrangement of wires are given.