Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop

Introduction. Since the development of the first active power filter (APF) in 1976, many efforts have been focused on improving the performances of the APF control as the number of different nonlinear loads has continued to increase. These nonlinear loads have led to the generation of different type...

Повний опис

Збережено в:
Бібліографічні деталі
Видавець:National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
Дата:2022
Автори: Chemidi, A., Benhabib, M. C., Bourouis, M. A.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/252869
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!

Репозиторії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-252869
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
topic active power filter
robust phase-locked loop
harmonics
particle swarm optimization-reference signal tracking controller
фільтр активної потужності
надійний контур фазового автопідстроювання частоти
гармоніки
контролер відстеження еталонного сигналу оптимізації рою частинок
spellingShingle active power filter
robust phase-locked loop
harmonics
particle swarm optimization-reference signal tracking controller
фільтр активної потужності
надійний контур фазового автопідстроювання частоти
гармоніки
контролер відстеження еталонного сигналу оптимізації рою частинок
Chemidi, A.
Benhabib, M. C.
Bourouis, M. A.
Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
topic_facet active power filter
robust phase-locked loop
harmonics
particle swarm optimization-reference signal tracking controller
фільтр активної потужності
надійний контур фазового автопідстроювання частоти
гармоніки
контролер відстеження еталонного сигналу оптимізації рою частинок
format Article
author Chemidi, A.
Benhabib, M. C.
Bourouis, M. A.
author_facet Chemidi, A.
Benhabib, M. C.
Bourouis, M. A.
author_sort Chemidi, A.
title Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_short Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_full Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_fullStr Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_full_unstemmed Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_sort performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
title_alt Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop
description Introduction. Since the development of the first active power filter (APF) in 1976, many efforts have been focused on improving the performances of the APF control as the number of different nonlinear loads has continued to increase. These nonlinear loads have led to the generation of different types of current harmonics, which requires more advanced controls, including robustness, to get an admissible total harmonic distortion (THD) in the power system. Purpose. The purpose of this paper is to develop a robust phase-locked loop (PLL) based on particle swarm optimization-reference signal tracking (PSO-RST) controller for a three phase three wires shunt active power filter control. Methodology. A robust PLL based on PSO-RST controller insert into the indirect d-q control of a shunt active power filter was developed. Results. Simulation results performed under the MATLAB/SimPowerSystem environment show a higher filtering quality and a better robustness compared to the classical d-q controls. Originality. Conventional PLLs have difficulty determining the phase angle of the utility voltage sources when grid voltage is distorted. If this phase angle is incorrectly determined, this leads to a malfunction of the complete control of the active power filters. This implies a bad compensation of the current harmonics generated by the nonlinear loads. To solve this problem we propose a robust and simple PLL based on PSO-RST controller to eliminate the influence of the voltage harmonics. Practical value. The proposed solution can be used to improve the functioning of the shunt active power filter and to reduce the amount of memory implementation.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2022
url http://eie.khpi.edu.ua/article/view/252869
work_keys_str_mv AT chemidia performanceimprovementofshuntactivepowerfilterbasedonindirectcontrolwithanewrobustphaselockedloop
AT benhabibmc performanceimprovementofshuntactivepowerfilterbasedonindirectcontrolwithanewrobustphaselockedloop
AT bourouisma performanceimprovementofshuntactivepowerfilterbasedonindirectcontrolwithanewrobustphaselockedloop
first_indexed 2024-06-01T14:40:06Z
last_indexed 2024-06-01T14:40:06Z
_version_ 1800670079364366336
spelling eiekhpieduua-article-2528692022-07-08T09:20:51Z Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop Performance improvement of shunt active power filter based on indirect control with a new robust phase-locked loop Chemidi, A. Benhabib, M. C. Bourouis, M. A. active power filter robust phase-locked loop harmonics particle swarm optimization-reference signal tracking controller фільтр активної потужності надійний контур фазового автопідстроювання частоти гармоніки контролер відстеження еталонного сигналу оптимізації рою частинок Introduction. Since the development of the first active power filter (APF) in 1976, many efforts have been focused on improving the performances of the APF control as the number of different nonlinear loads has continued to increase. These nonlinear loads have led to the generation of different types of current harmonics, which requires more advanced controls, including robustness, to get an admissible total harmonic distortion (THD) in the power system. Purpose. The purpose of this paper is to develop a robust phase-locked loop (PLL) based on particle swarm optimization-reference signal tracking (PSO-RST) controller for a three phase three wires shunt active power filter control. Methodology. A robust PLL based on PSO-RST controller insert into the indirect d-q control of a shunt active power filter was developed. Results. Simulation results performed under the MATLAB/SimPowerSystem environment show a higher filtering quality and a better robustness compared to the classical d-q controls. Originality. Conventional PLLs have difficulty determining the phase angle of the utility voltage sources when grid voltage is distorted. If this phase angle is incorrectly determined, this leads to a malfunction of the complete control of the active power filters. This implies a bad compensation of the current harmonics generated by the nonlinear loads. To solve this problem we propose a robust and simple PLL based on PSO-RST controller to eliminate the influence of the voltage harmonics. Practical value. The proposed solution can be used to improve the functioning of the shunt active power filter and to reduce the amount of memory implementation. Вступ. З моменту розробки першого фільтра активної потужності (ФАП) у 1976 р. багато зусиль було спрямовано на покращення характеристик управління ФАП, оскільки кількість різних нелінійних навантажень продовжувала зростати. Ці нелінійні навантаження призвели до генерації різних типів гармонік струму, що потребує більш досконалих засобів управління, у тому числі стійких, для отримання допустимого повного гармонічного спотворення (THD) в енергосистемі. Мета. Метою даної статті є розробка надійного контуру фазового автопідстроювання частоти (ФАПЧ) на основі контролера відстеження еталонного сигналу оптимізації рою частинок (ВЕС ОРЧ) для трифазного трипровідного шунтуючого фільтра активної потужності. Методологія. Розроблено надійну систему ФАПЧ на основі контролера ВЕС ОРЧ, вбудованого в непрямий d-q контроль шунтуючого фільтра активної потужності. Результати. Результати моделювання, виконаного в середовищі MATLAB/SimPowerSystem, демонструють високу якість фільтрації та більшу надійність у порівнянні з класичним d-q керуванням. Оригінальність. Звичайні ФАПЧ мають труднощі з визначенням фазового кута джерел напруги, коли напруга мережі спотворена. Неправильне визначення цього фазового кута призводить до порушення повного керування фільтрами активної потужності. Це означає погану компенсацію гармонік струму, створюваних нелінійними навантаженнями. Для вирішення цієї проблеми ми пропонуємо стійкий та простий ФАПЧ на основі контролера ВЕС ОРЧ для усунення впливу гармонік напруги. Практична цінність. Запропоноване рішення може бути використане для поліпшення роботи шунтуючого фільтра активної потужності і зменшення обсягу потрібної пам'яті.  National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022-07-08 Article Article application/pdf http://eie.khpi.edu.ua/article/view/252869 10.20998/2074-272X.2022.4.07 Electrical Engineering & Electromechanics; No. 4 (2022); 51-56 Электротехника и Электромеханика; № 4 (2022); 51-56 Електротехніка і Електромеханіка; № 4 (2022); 51-56 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/252869/257497 Copyright (c) 2022 A. Chemidi, M. C. Benhabib, M. A. Bourouis http://creativecommons.org/licenses/by-nc/4.0