Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program

Introduction. In high voltage networks intended for the transport of electrical energy, lightning can strike an electric line striking either a phase conductor, a pylon or a ground wire, causing significant overvoltage on the transmission lines classified as stresses the most dangerous for transform...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2022
Автори: Boumous, S., Boumous, Z., Anane, Z., Nouri, H.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/253573
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-253573
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
topic high voltage
lightning strike
electromagnetic and alternative transients program
line models
висока напруга
удар блискавки
програма електромагнітних та альтернативних перехідних процесів
моделі ліній
spellingShingle high voltage
lightning strike
electromagnetic and alternative transients program
line models
висока напруга
удар блискавки
програма електромагнітних та альтернативних перехідних процесів
моделі ліній
Boumous, S.
Boumous, Z.
Anane, Z.
Nouri, H.
Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
topic_facet high voltage
lightning strike
electromagnetic and alternative transients program
line models
висока напруга
удар блискавки
програма електромагнітних та альтернативних перехідних процесів
моделі ліній
format Article
author Boumous, S.
Boumous, Z.
Anane, Z.
Nouri, H.
author_facet Boumous, S.
Boumous, Z.
Anane, Z.
Nouri, H.
author_sort Boumous, S.
title Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_short Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_full Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_fullStr Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_full_unstemmed Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_sort comparative study of 220 kv overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
title_alt Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program
description Introduction. In high voltage networks intended for the transport of electrical energy, lightning can strike an electric line striking either a phase conductor, a pylon or a ground wire, causing significant overvoltage on the transmission lines classified as stresses the most dangerous for transformer stations and electro-energy systems in general. Modeling transmission lines becomes more complicated, if the frequency dependence of resistance and serial inductance due to the effect of lightning strike in the conductors and in the earth is considered. The difficulty increases the fact that the parameters of the line can be defined and calculated only in the frequency domain, while the simulation of transients is wanted to be in the time domain. Problem. Several models (J.R. Marti, Bergeron, nominal PI, Semlyen and Noda) exist for the modeling of transmission lines, the Electromagnetic Transients Program/Alternative Transient Program software (EMTP/ATPDraw) gives the possibility to choose between these models which is delicate due to the fact that we do not have experimental results to validate and justify the choice among the models available in the software. In this context, practical value: the overhead transport line OAT-El Hassi (220 kV) of the city of Sétif located in the north east of Algeria is used for the modeling of lightning strike by using the EMTP/ATPDraw software. Originality. A comparative study of the investigation of a lightning strike on an existing high voltage transmission line by different models of existing lines in the EMTP/ATPDraw software library of this software. Results. It was concluded that the choice of the model of the line is very important given the accuracy and quality of the curves of the voltage presented at the different calculation points. 
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2022
url http://eie.khpi.edu.ua/article/view/253573
work_keys_str_mv AT boumouss comparativestudyof220kvoverheadtransmissionlinesmodelssubjectedtolightningstrikesimulationbyusingelectromagneticandalternativetransientsprogram
AT boumousz comparativestudyof220kvoverheadtransmissionlinesmodelssubjectedtolightningstrikesimulationbyusingelectromagneticandalternativetransientsprogram
AT ananez comparativestudyof220kvoverheadtransmissionlinesmodelssubjectedtolightningstrikesimulationbyusingelectromagneticandalternativetransientsprogram
AT nourih comparativestudyof220kvoverheadtransmissionlinesmodelssubjectedtolightningstrikesimulationbyusingelectromagneticandalternativetransientsprogram
first_indexed 2024-06-01T14:40:07Z
last_indexed 2024-06-01T14:40:07Z
_version_ 1800670080342687744
spelling eiekhpieduua-article-2535732022-07-08T09:20:51Z Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program Comparative study of 220 kV overhead transmission lines models subjected to lightning strike simulation by using electromagnetic and alternative transients program Boumous, S. Boumous, Z. Anane, Z. Nouri, H. high voltage lightning strike electromagnetic and alternative transients program line models висока напруга удар блискавки програма електромагнітних та альтернативних перехідних процесів моделі ліній Introduction. In high voltage networks intended for the transport of electrical energy, lightning can strike an electric line striking either a phase conductor, a pylon or a ground wire, causing significant overvoltage on the transmission lines classified as stresses the most dangerous for transformer stations and electro-energy systems in general. Modeling transmission lines becomes more complicated, if the frequency dependence of resistance and serial inductance due to the effect of lightning strike in the conductors and in the earth is considered. The difficulty increases the fact that the parameters of the line can be defined and calculated only in the frequency domain, while the simulation of transients is wanted to be in the time domain. Problem. Several models (J.R. Marti, Bergeron, nominal PI, Semlyen and Noda) exist for the modeling of transmission lines, the Electromagnetic Transients Program/Alternative Transient Program software (EMTP/ATPDraw) gives the possibility to choose between these models which is delicate due to the fact that we do not have experimental results to validate and justify the choice among the models available in the software. In this context, practical value: the overhead transport line OAT-El Hassi (220 kV) of the city of Sétif located in the north east of Algeria is used for the modeling of lightning strike by using the EMTP/ATPDraw software. Originality. A comparative study of the investigation of a lightning strike on an existing high voltage transmission line by different models of existing lines in the EMTP/ATPDraw software library of this software. Results. It was concluded that the choice of the model of the line is very important given the accuracy and quality of the curves of the voltage presented at the different calculation points.  Вступ. У високовольтних мережах, призначених для передачі електроенергії, блискавка може вдарити по лінії електропередач, уразивши або фазний провід, опору, або заземлюючий провід, викликаючи значні перенапруги на лініях електропередач, визначені як загрози, найбільш небезпечні для трансформаторних підстанцій та електроенергетичних систем загалом. Моделювання ліній електропередач ускладнюється, якщо враховувати частотну залежність опору та послідовної індуктивності внаслідок дії удару блискавки у провідниках та землі. Складність підвищується тим, що параметри лінії можуть бути визначені і розраховані тільки в частотній області, в той час як моделювання перехідних процесів бажано проводити в часовій області. Проблема. Існує кілька моделей (J.R. Marti, Bergeron, номінальна П-подібна схема заміщення, Semlyen і Noda) для моделювання ліній електропередач, комп‘ютерна  програма електромагнітних перехідних процесів/альтернативна програма перехідних процесів EMTP/ATPDraw дає можливість вибирати між цими моделями, що є «тонким питанням» через те, що ми не маємо експериментальних результатів для перевірки та обґрунтування вибору серед моделей, доступних у програмному забезпеченні. У цьому контексті, практична цінність: для моделювання удару блискавки за допомогою програмного забезпечення EMTP/ATPDraw використана повітряна лінія електропередачі ОАТ-Ель-Хассі (220 кВ) міста Сетіф, розташованого на північному сході Алжиру. Оригінальність. Порівняльне дослідження вивчення удару блискавки на існуючій високовольтній лінії електропередач за різними моделями існуючих ліній у бібліотеці програм  EMTP/ATPDraw цього програмного забезпечення. Результати. Зроблено висновок, що вибір моделі лінії дуже важливий з урахуванням точності та якості кривих напруг, представлених у різних розрахункових точках.  National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2022-07-08 Article Article application/pdf http://eie.khpi.edu.ua/article/view/253573 10.20998/2074-272X.2022.4.10 Electrical Engineering & Electromechanics; No. 4 (2022); 68-74 Электротехника и Электромеханика; № 4 (2022); 68-74 Електротехніка і Електромеханіка; № 4 (2022); 68-74 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/253573/257544 Copyright (c) 2022 S. Boumous, Z. Boumous, Z. Anane, H. Nouri http://creativecommons.org/licenses/by-nc/4.0