Determination of the scope of the experimental-calculation method for measuring the touch voltage

The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations. The aim of the work is determination of the scope of the experimental-calculated method for measuring the touch voltage, depending on...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2023
Автори: Koliushko, D. G., Rudenko, S. S., Saliba, A. N.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2023
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/271079
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-271079
record_format ojs
spelling eiekhpieduua-article-2710792023-01-04T13:48:14Z Determination of the scope of the experimental-calculation method for measuring the touch voltage Determination of the scope of the experimental-calculation method for measuring the touch voltage Koliushko, D. G. Rudenko, S. S. Saliba, A. N. електрична підстанція заземлювальний пристрій моделювання електромагнітних процесів напруга дотику характеристики ґрунту коротке замикання electrical substations grounding system modeling of the electromagnetic processes touch voltage soil characteristics short-circuit The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations. The aim of the work is determination of the scope of the experimental-calculated method for measuring the touch voltage, depending on short-circuit (SC) current value for the given dimensions of the GS and the type of soil. Methodology. The study analyzed the non-linear effect of the SC current value on the touch voltage, taking into account such factors as the GS size and the soil type. The calculation used statistical data on the GS size and the characteristics of the soil obtained by monitoring the GS state of 585 operating electrical substations with a voltage class of 110-750 kV using the induction method and the method of vertical soil sounding, respectively. For the calculation, a mathematical model of a non-equipotential GS located in a three-layer semiconductor space with plane-parallel boundaries was used, this model was developed using the method of integro-differential equations. Results. To determine the scope of the method, in this work it is proposed to use the linearity criterion, which is determined due to the ratio of the constant of reduced touch voltage to the current value. The example shows the method for determining the threshold minimum and maximum values of the measuring current of the soil, in the range between which the measurements by experimental-calculated methods are impossible. A table of threshold current values has been formed and recommendations have been developed on the possibility of using experimental-measuring methods for determining the touch voltage depending on the GS size and soil characteristics. Метою роботи є визначення області застосування експериментально-розрахункового методу вимірювання напруги дотику в залежності від значення струму короткого замикання для заданих розмірів заземлювального пристрою (ЗП) та типу ґрунту. В дослідженні було проаналізовано нелінійний вплив величини струму КЗ на напругу дотику з урахуванням таких факторів як розмір ЗП та тип ґрунту. Для розрахунку була використана математична модель нееквіпотенційного ЗП, розташованого у тришаровому напівпровідному просторі з плоско-паралельними границями поділу, що була розроблена за допомогою методу інтегро-диференційних рівнянь. Для визначення області застосування методу в роботі запропоновано використовувати критерій лінійності, який визначається через відношення сталої приведеної напруги дотику до поточного значення. Сформовано таблицю значень порогових струмів та розроблено рекомендації щодо можливості використання експериментально-вимірювальних методів визначення напруги дотику в залежності від розміру ЗП та характеристик ґрунту. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2023-01-04 Article Article application/pdf http://eie.khpi.edu.ua/article/view/271079 10.20998/2074-272X.2023.1.11 Electrical Engineering & Electromechanics; No. 1 (2023); 77-82 Электротехника и Электромеханика; № 1 (2023); 77-82 Електротехніка і Електромеханіка; № 1 (2023); 77-82 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/271079/266577 Copyright (c) 2023 D. G. Koliushko, S. S. Rudenko, A. N. Saliba http://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2023-01-04T13:48:14Z
collection OJS
language English
topic electrical substations
grounding system
modeling of the electromagnetic processes
touch voltage
soil characteristics
short-circuit
spellingShingle electrical substations
grounding system
modeling of the electromagnetic processes
touch voltage
soil characteristics
short-circuit
Koliushko, D. G.
Rudenko, S. S.
Saliba, A. N.
Determination of the scope of the experimental-calculation method for measuring the touch voltage
topic_facet електрична підстанція
заземлювальний пристрій
моделювання електромагнітних процесів
напруга дотику
характеристики ґрунту
коротке замикання
electrical substations
grounding system
modeling of the electromagnetic processes
touch voltage
soil characteristics
short-circuit
format Article
author Koliushko, D. G.
Rudenko, S. S.
Saliba, A. N.
author_facet Koliushko, D. G.
Rudenko, S. S.
Saliba, A. N.
author_sort Koliushko, D. G.
title Determination of the scope of the experimental-calculation method for measuring the touch voltage
title_short Determination of the scope of the experimental-calculation method for measuring the touch voltage
title_full Determination of the scope of the experimental-calculation method for measuring the touch voltage
title_fullStr Determination of the scope of the experimental-calculation method for measuring the touch voltage
title_full_unstemmed Determination of the scope of the experimental-calculation method for measuring the touch voltage
title_sort determination of the scope of the experimental-calculation method for measuring the touch voltage
title_alt Determination of the scope of the experimental-calculation method for measuring the touch voltage
description The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations. The aim of the work is determination of the scope of the experimental-calculated method for measuring the touch voltage, depending on short-circuit (SC) current value for the given dimensions of the GS and the type of soil. Methodology. The study analyzed the non-linear effect of the SC current value on the touch voltage, taking into account such factors as the GS size and the soil type. The calculation used statistical data on the GS size and the characteristics of the soil obtained by monitoring the GS state of 585 operating electrical substations with a voltage class of 110-750 kV using the induction method and the method of vertical soil sounding, respectively. For the calculation, a mathematical model of a non-equipotential GS located in a three-layer semiconductor space with plane-parallel boundaries was used, this model was developed using the method of integro-differential equations. Results. To determine the scope of the method, in this work it is proposed to use the linearity criterion, which is determined due to the ratio of the constant of reduced touch voltage to the current value. The example shows the method for determining the threshold minimum and maximum values of the measuring current of the soil, in the range between which the measurements by experimental-calculated methods are impossible. A table of threshold current values has been formed and recommendations have been developed on the possibility of using experimental-measuring methods for determining the touch voltage depending on the GS size and soil characteristics.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2023
url http://eie.khpi.edu.ua/article/view/271079
work_keys_str_mv AT koliushkodg determinationofthescopeoftheexperimentalcalculationmethodformeasuringthetouchvoltage
AT rudenkoss determinationofthescopeoftheexperimentalcalculationmethodformeasuringthetouchvoltage
AT salibaan determinationofthescopeoftheexperimentalcalculationmethodformeasuringthetouchvoltage
first_indexed 2025-07-17T11:49:36Z
last_indexed 2025-07-17T11:49:36Z
_version_ 1850412098114289664