EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER

Experimental studies of ferromagnetic core parameters action on electromechanical characteristics of a linear induction-dynamic converter are conducted. An experimental installation is designed and built to determine the converter electromechanical parameters during its operation. A ferromagnetic co...

Full description

Saved in:
Bibliographic Details
Date:2014
Main Authors: Bolyukh, V. F., Oleksenko, S. V., Schukin, I. S.
Format: Article
Language:Russian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2014.5.02
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-28070
record_format ojs
spelling eiekhpieduua-article-280702017-12-27T11:48:36Z EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ВЛИЯНИЯ ПАРАМЕТРОВ ФЕРРОМАГНИТНОГО СЕРДЕЧНИКА НА ЭЛЕКТРОМЕХАНИЧЕСКИЕ ПОКАЗАТЕЛИ ЛИНЕЙНОГО ИНДУКЦИОННО-ДИНАМИЧЕСКОГО ПРЕОБРАЗОВАТЕЛЯ ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ВЛИЯНИЯ ПАРАМЕТРОВ ФЕРРОМАГНИТНОГО СЕРДЕЧНИКА НА ЭЛЕКТРОМЕХАНИЧЕСКИЕ ПОКАЗАТЕЛИ ЛИНЕЙНОГО ИНДУКЦИОННО-ДИНАМИЧЕСКОГО ПРЕОБРАЗОВАТЕЛЯ Bolyukh, V. F. Oleksenko, S. V. Schukin, I. S. linear induction-dynamic converter core experimental studies electromechanical characteristics 621.313 536.2.24 539.2 linear induction-dynamic converter core experimental studies electromechanical characteristics 621.313 536.2.24 539.2 linear induction-dynamic converter core experimental studies electromechanical characteristics 621.313 536.2.24 539.2 Experimental studies of ferromagnetic core parameters action on electromechanical characteristics of a linear induction-dynamic converter are conducted. An experimental installation is designed and built to determine the converter electromechanical parameters during its operation. A ferromagnetic core with four radial slots made allows regulating the height of the base and the outer shell. The core geometric parameters providing the highest speed of the armature are specified. Under certain parameters, the ferromagnetic core increases the converter efficiency up to 50%. The experimental results confirm the analytical studies within 6 % error. Проведены экспериментальные исследования влияния параметров ферромагнитного сердечника на электромеханические показатели линейного индукционно-динамического преобразователя. Разработана экспериментальная установка, позволяющая определять электромеханические параметры преобразователя в течение рабочего процесса. Изготовлен ферромагнитный сердечник с четырьмя радиальными разрезами, позволяющий регулировать высоту основания и наружной обечайки. Установлены геометрические параметры сердечника, обеспечивающего наибольшую скорость якоря. При определенных параметрах ферромагнитный сердечник повышает эффективность преобразователя до 50%. Экспериментальные исследования с погрешностью до 6 % подтверждают теоретические расчеты. Проведені експериментальні дослідження впливу параметрів феромагнітного осердя на електромеханічні показники лінійного індукційно-динамічного перетворювача. Розроблена експериментальна установка, яка дозволяє визначати електромеханічні параметри перетворювача на протязі робочого процесу. Виготовлене феромагнітне осердя з чотирма радіальними розрізами, яке дозволяє регулювати висоту основи та зовнішньої обичайки. Визначені геометричні параметри осердя, які забезпечують найбільшу швидкість якоря. При певних параметрах феромагнітне осердя підвищує ефективність перетворювача до 50 %. Експериментальні дослідження з похибкою до 6 % підтверджують теоретичні розрахунки. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014-10-14 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2014.5.02 10.20998/2074-272X.2014.5.02 Electrical Engineering & Electromechanics; No. 5 (2014); 13-18 Электротехника и Электромеханика; № 5 (2014); 13-18 Електротехніка і Електромеханіка; № 5 (2014); 13-18 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2014.5.02/25052 Copyright (c) 2015 V. F. Bolyukh, S. V. Oleksenko, I. S. Schukin https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2017-12-27T11:48:36Z
collection OJS
language Russian
topic linear induction-dynamic converter
core
experimental studies
electromechanical characteristics
621.313
536.2.24
539.2
spellingShingle linear induction-dynamic converter
core
experimental studies
electromechanical characteristics
621.313
536.2.24
539.2
Bolyukh, V. F.
Oleksenko, S. V.
Schukin, I. S.
EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
topic_facet linear induction-dynamic converter
core
experimental studies
electromechanical characteristics
621.313
536.2.24
539.2
linear induction-dynamic converter
core
experimental studies
electromechanical characteristics
621.313
536.2.24
539.2
linear induction-dynamic converter
core
experimental studies
electromechanical characteristics
621.313
536.2.24
539.2
format Article
author Bolyukh, V. F.
Oleksenko, S. V.
Schukin, I. S.
author_facet Bolyukh, V. F.
Oleksenko, S. V.
Schukin, I. S.
author_sort Bolyukh, V. F.
title EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
title_short EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
title_full EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
title_fullStr EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
title_full_unstemmed EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER
title_sort experimental study of ferromagnetic core parameters influence on electromechanical characteristics of a linear induction-dynamic converter
title_alt ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ВЛИЯНИЯ ПАРАМЕТРОВ ФЕРРОМАГНИТНОГО СЕРДЕЧНИКА НА ЭЛЕКТРОМЕХАНИЧЕСКИЕ ПОКАЗАТЕЛИ ЛИНЕЙНОГО ИНДУКЦИОННО-ДИНАМИЧЕСКОГО ПРЕОБРАЗОВАТЕЛЯ
ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ВЛИЯНИЯ ПАРАМЕТРОВ ФЕРРОМАГНИТНОГО СЕРДЕЧНИКА НА ЭЛЕКТРОМЕХАНИЧЕСКИЕ ПОКАЗАТЕЛИ ЛИНЕЙНОГО ИНДУКЦИОННО-ДИНАМИЧЕСКОГО ПРЕОБРАЗОВАТЕЛЯ
description Experimental studies of ferromagnetic core parameters action on electromechanical characteristics of a linear induction-dynamic converter are conducted. An experimental installation is designed and built to determine the converter electromechanical parameters during its operation. A ferromagnetic core with four radial slots made allows regulating the height of the base and the outer shell. The core geometric parameters providing the highest speed of the armature are specified. Under certain parameters, the ferromagnetic core increases the converter efficiency up to 50%. The experimental results confirm the analytical studies within 6 % error.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2014
url http://eie.khpi.edu.ua/article/view/2074-272X.2014.5.02
work_keys_str_mv AT bolyukhvf experimentalstudyofferromagneticcoreparametersinfluenceonelectromechanicalcharacteristicsofalinearinductiondynamicconverter
AT oleksenkosv experimentalstudyofferromagneticcoreparametersinfluenceonelectromechanicalcharacteristicsofalinearinductiondynamicconverter
AT schukinis experimentalstudyofferromagneticcoreparametersinfluenceonelectromechanicalcharacteristicsofalinearinductiondynamicconverter
AT bolyukhvf éksperimentalʹnyeissledovaniâvliâniâparametrovferromagnitnogoserdečnikanaélektromehaničeskiepokazatelilinejnogoindukcionnodinamičeskogopreobrazovatelâ
AT oleksenkosv éksperimentalʹnyeissledovaniâvliâniâparametrovferromagnitnogoserdečnikanaélektromehaničeskiepokazatelilinejnogoindukcionnodinamičeskogopreobrazovatelâ
AT schukinis éksperimentalʹnyeissledovaniâvliâniâparametrovferromagnitnogoserdečnikanaélektromehaničeskiepokazatelilinejnogoindukcionnodinamičeskogopreobrazovatelâ
first_indexed 2025-07-17T11:44:54Z
last_indexed 2025-07-17T11:44:54Z
_version_ 1850411185062543360