Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator

Introduction. The best way to control the torque of an induction motor is conventional direct torque control (DTC); this control method is the most used approach in the industrial sector due to its many advantages. Its main advantages are its simplicity and its exclusive dependence on the stator res...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2023
Автори: Mabrouk, Y. A., Mokhtari, B., Allaoui, T.
Формат: Стаття
Мова:English
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2023
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/285010
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-285010
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
topic пряме управління крутним моментом
контролер нечіткої логіки
пристрій оцінки нечіткої логіки
асинхронний двигун
спектральний аналіз
повне гармонійне спотворення
direct torque control
fuzzy logic controller
fuzzy logic estimator
induction motor
spectral analysis
total harmonic distortion
spellingShingle пряме управління крутним моментом
контролер нечіткої логіки
пристрій оцінки нечіткої логіки
асинхронний двигун
спектральний аналіз
повне гармонійне спотворення
direct torque control
fuzzy logic controller
fuzzy logic estimator
induction motor
spectral analysis
total harmonic distortion
Mabrouk, Y. A.
Mokhtari, B.
Allaoui, T.
Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
topic_facet пряме управління крутним моментом
контролер нечіткої логіки
пристрій оцінки нечіткої логіки
асинхронний двигун
спектральний аналіз
повне гармонійне спотворення
direct torque control
fuzzy logic controller
fuzzy logic estimator
induction motor
spectral analysis
total harmonic distortion
format Article
author Mabrouk, Y. A.
Mokhtari, B.
Allaoui, T.
author_facet Mabrouk, Y. A.
Mokhtari, B.
Allaoui, T.
author_sort Mabrouk, Y. A.
title Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_short Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_full Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_fullStr Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_full_unstemmed Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_sort frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
title_alt Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator
description Introduction. The best way to control the torque of an induction motor is conventional direct torque control (DTC); this control method is the most used approach in the industrial sector due to its many advantages. Its main advantages are its simplicity and its exclusive dependence on the stator resistance of the induction motor. However, the use of hysteresis comparators reduces its effectiveness, causing more torque ripple. Additionally, this results in variable operating frequency and limited frequency sampling, resulting in pseudo-random overshoot of the hysteresis band. Purpose. For these reasons, this article presents a new study aimed at confirming its shortcomings and improving the effectiveness of the control. Novelty. We propose to use fuzzy logic methods to estimate the two components of the stator flux. Methods. In traditional DTC the flux components are estimated from an equation relating the stator resistance to the stator voltage and current. In the proposed method, only stator currents and voltages are used for this evaluation, which eliminates the dependence of DTC on stator resistance. The aim of this proposal is to make DTC robust to parametric changes. Results. General harmonic distortions, rotational speed of the induction motor, electromagnetic moment, magnetic flux and stator currents are analyzed. Practical value. With this proposed technique, validated in Simulink/MATLAB, several improvements in motor behavior and control are endorsed: torque fluctuations are reduced, overshoot is completely eliminated, and total harmonic distortion is significantly reduced by 48.31 % for stator currents. This study also confirmed the robustness of DTC to changes in stator resistance.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2023
url http://eie.khpi.edu.ua/article/view/285010
work_keys_str_mv AT mabroukya frequencyanalysisofstatorcurrentsofaninductionmotorcontrolledbydirecttorquecontrolassociatedwithafuzzyfluxestimator
AT mokhtarib frequencyanalysisofstatorcurrentsofaninductionmotorcontrolledbydirecttorquecontrolassociatedwithafuzzyfluxestimator
AT allaouit frequencyanalysisofstatorcurrentsofaninductionmotorcontrolledbydirecttorquecontrolassociatedwithafuzzyfluxestimator
first_indexed 2024-06-01T14:40:36Z
last_indexed 2024-06-01T14:40:36Z
_version_ 1800670110715740160
spelling eiekhpieduua-article-2850102023-10-21T17:48:38Z Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator Frequency analysis of stator currents of an induction motor controlled by direct torque control associated with a fuzzy flux estimator Mabrouk, Y. A. Mokhtari, B. Allaoui, T. пряме управління крутним моментом контролер нечіткої логіки пристрій оцінки нечіткої логіки асинхронний двигун спектральний аналіз повне гармонійне спотворення direct torque control fuzzy logic controller fuzzy logic estimator induction motor spectral analysis total harmonic distortion Introduction. The best way to control the torque of an induction motor is conventional direct torque control (DTC); this control method is the most used approach in the industrial sector due to its many advantages. Its main advantages are its simplicity and its exclusive dependence on the stator resistance of the induction motor. However, the use of hysteresis comparators reduces its effectiveness, causing more torque ripple. Additionally, this results in variable operating frequency and limited frequency sampling, resulting in pseudo-random overshoot of the hysteresis band. Purpose. For these reasons, this article presents a new study aimed at confirming its shortcomings and improving the effectiveness of the control. Novelty. We propose to use fuzzy logic methods to estimate the two components of the stator flux. Methods. In traditional DTC the flux components are estimated from an equation relating the stator resistance to the stator voltage and current. In the proposed method, only stator currents and voltages are used for this evaluation, which eliminates the dependence of DTC on stator resistance. The aim of this proposal is to make DTC robust to parametric changes. Results. General harmonic distortions, rotational speed of the induction motor, electromagnetic moment, magnetic flux and stator currents are analyzed. Practical value. With this proposed technique, validated in Simulink/MATLAB, several improvements in motor behavior and control are endorsed: torque fluctuations are reduced, overshoot is completely eliminated, and total harmonic distortion is significantly reduced by 48.31 % for stator currents. This study also confirmed the robustness of DTC to changes in stator resistance. Вступ. Найкращим способом управління крутним моментом асинхронного двигуна є традиційне пряме управління крутним моментом (DTC); цей метод управління є найбільш використовуваним у промисловому секторі через його численні переваги. Його основними перевагами є простота та виключна залежність від опору статора асинхронного двигуна. Однак використання гістерезисних компараторів знижує його ефективність, викликаючи велику пульсацію крутного моменту. Крім того, це призводить до зміни робочої частоти та обмеження вибірки частоти, що призводить до псевдовипадкового виходу за межі смуги гістерезису. Мета. З цих причин у цій статті представлено нове дослідження, спрямоване на підтвердження його недоліків та підвищення ефективності контролю. Новизна. Ми пропонуємо використовувати методи нечіткої логіки з метою оцінки двох компонентів потоку статора. Методи. У традиційному DTC компоненти потоку оцінюються за рівнянням, що зв'язує опір статора з напругою та струмом статора. У запропонованому методі цієї оцінки використовуються лише струми і напруги статора, що виключає залежність DTC від опору статора. Мета цієї пропозиції – зробити DTC стійким до параметричних змін. Результати. Аналізуються загальні гармонічні спотворення, швидкість обертання асинхронного двигуна, електромагнітний момент, магнітний потік та струми статору. Практична цінність. За допомогою цього запропонованого методу, перевіреного в Simulink/MATLAB, підтверджено кілька покращень у поведінці та управління двигуном: коливання крутного моменту зменшуються, перерегулювання повністю усувається, а загальні гармонічні спотворення значно зменшуються на 48,31% для струмів статора. Це дослідження підтвердило стійкість DTC до змін опору статора. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2023-10-21 Article Article application/pdf http://eie.khpi.edu.ua/article/view/285010 10.20998/2074-272X.2023.6.05 Electrical Engineering & Electromechanics; No. 6 (2023); 27-32 Электротехника и Электромеханика; № 6 (2023); 27-32 Електротехніка і Електромеханіка; № 6 (2023); 27-32 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/285010/282208 Copyright (c) 2023 Y. A. Mabrouk, B. Mokhtari, T. Allaoui http://creativecommons.org/licenses/by-nc/4.0