Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles

Purpose. Determination by means of computer simulation of the most efficient modes of operation of the installation for water disinfection using discharges in gas bubbles, in which (modes) the amplitude of voltage pulses at the processing unit and on the layer of treated water is not less than the v...

Full description

Saved in:
Bibliographic Details
Date:2024
Main Authors: Boiko, M. I., Tatkova, K. S.
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2024
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/293402
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-293402
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2024-01-01T09:17:37Z
collection OJS
language English
topic high-voltage water disinfection unit
discharge unit
sharpening spark gap
discharge in gas bubbles in water
discharge delay time
long electric line
spellingShingle high-voltage water disinfection unit
discharge unit
sharpening spark gap
discharge in gas bubbles in water
discharge delay time
long electric line
Boiko, M. I.
Tatkova, K. S.
Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
topic_facet high-voltage water disinfection unit
discharge unit
sharpening spark gap
discharge in gas bubbles in water
discharge delay time
long electric line
високовольтна установка для знезараження води
розрядний вузол
розрядник
що загострює
розряд у газових бульбашках у воді
час запізнення розряду
довга електрична лінія
format Article
author Boiko, M. I.
Tatkova, K. S.
author_facet Boiko, M. I.
Tatkova, K. S.
author_sort Boiko, M. I.
title Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_short Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_full Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_fullStr Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_full_unstemmed Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_sort computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
title_alt Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles
description Purpose. Determination by means of computer simulation of the most efficient modes of operation of the installation for water disinfection using discharges in gas bubbles, in which (modes) the amplitude of voltage pulses at the processing unit and on the layer of treated water is not less than the voltage amplitude immediately after the switching discharger. Methodology. To achieve this goal, we used computer simulation using Micro-Cap 10. We used two different electrical circuits that simulate the operation of the experimental setup in two different modes: in a mode with a restoring electrical strength of the discharge gap in the gas bubble between two adjacent voltage pulses on the discharge node and in the mode without restoring this dielectric strength. In computer simulation, we varied the following factors: the maximum simulation step, inductances, capacitances, active resistances, wave resistance of a long line, and the delay time for the operation of a spark gap simulating a discharge gap in a gas bubble. Results. Computer modeling has shown that in order to increase the voltage amplitude at the treatment unit and on the layer of treated water, it is necessary to reduce the load capacitance – the capacitance of the water layer in the treatment unit to 10 pF or less, to increase the active resistance of the water layer to 500 W or more. An important factor for increasing the voltage and electric field strength in the discharge unit and, consequently, for increasing the efficiency of treated water disinfection is the discharge delay time in gas bubbles. The most rational delay time for the operation of the arrester, which is the gap in the gas bubble inside the water, under the conditions considered by us is 4–5 ns. It is with this delay time that the amplitude of voltage pulses at the node of disinfecting water treatment and on the layer of treated water is maximum, all other things being equal. Furthermore, with such a delay time this amplitude of voltage pulses significantly exceeds the voltage amplitude directly after the main high-voltage discharger, switching energy from the high-voltage capacitive storage to the processing unit through a long line filled with water. Originality. Using computer simulation, we have shown the possibility of increasing the voltage at the discharge unit of the experimental setup by 35 % without increasing the voltage of the power source. This provides a higher efficiency of microbiological disinfection of water by nanosecond discharges in gas bubbles and lower specific energy consumption. Practical value. The obtained results of computer simulation confirm the prospect of industrial application of installations using nanosecond discharges for disinfection and purification of wastewater, swimming pools and post-treatment of tap water.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2024
url http://eie.khpi.edu.ua/article/view/293402
work_keys_str_mv AT boikomi computersimulationofoperationplanteffectivemodesforwaterdisinfectionbyelectricaldischargesingasbubbles
AT tatkovaks computersimulationofoperationplanteffectivemodesforwaterdisinfectionbyelectricaldischargesingasbubbles
first_indexed 2025-07-17T11:49:59Z
last_indexed 2025-07-17T11:49:59Z
_version_ 1850412145173331968
spelling eiekhpieduua-article-2934022024-01-01T09:17:37Z Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles Computer simulation of operation plant effective modes for water disinfection by electrical discharges in gas bubbles Boiko, M. I. Tatkova, K. S. high-voltage water disinfection unit discharge unit sharpening spark gap discharge in gas bubbles in water discharge delay time long electric line високовольтна установка для знезараження води розрядний вузол розрядник, що загострює розряд у газових бульбашках у воді час запізнення розряду довга електрична лінія Purpose. Determination by means of computer simulation of the most efficient modes of operation of the installation for water disinfection using discharges in gas bubbles, in which (modes) the amplitude of voltage pulses at the processing unit and on the layer of treated water is not less than the voltage amplitude immediately after the switching discharger. Methodology. To achieve this goal, we used computer simulation using Micro-Cap 10. We used two different electrical circuits that simulate the operation of the experimental setup in two different modes: in a mode with a restoring electrical strength of the discharge gap in the gas bubble between two adjacent voltage pulses on the discharge node and in the mode without restoring this dielectric strength. In computer simulation, we varied the following factors: the maximum simulation step, inductances, capacitances, active resistances, wave resistance of a long line, and the delay time for the operation of a spark gap simulating a discharge gap in a gas bubble. Results. Computer modeling has shown that in order to increase the voltage amplitude at the treatment unit and on the layer of treated water, it is necessary to reduce the load capacitance – the capacitance of the water layer in the treatment unit to 10 pF or less, to increase the active resistance of the water layer to 500 W or more. An important factor for increasing the voltage and electric field strength in the discharge unit and, consequently, for increasing the efficiency of treated water disinfection is the discharge delay time in gas bubbles. The most rational delay time for the operation of the arrester, which is the gap in the gas bubble inside the water, under the conditions considered by us is 4–5 ns. It is with this delay time that the amplitude of voltage pulses at the node of disinfecting water treatment and on the layer of treated water is maximum, all other things being equal. Furthermore, with such a delay time this amplitude of voltage pulses significantly exceeds the voltage amplitude directly after the main high-voltage discharger, switching energy from the high-voltage capacitive storage to the processing unit through a long line filled with water. Originality. Using computer simulation, we have shown the possibility of increasing the voltage at the discharge unit of the experimental setup by 35 % without increasing the voltage of the power source. This provides a higher efficiency of microbiological disinfection of water by nanosecond discharges in gas bubbles and lower specific energy consumption. Practical value. The obtained results of computer simulation confirm the prospect of industrial application of installations using nanosecond discharges for disinfection and purification of wastewater, swimming pools and post-treatment of tap water. Мета. Визначення за допомогою комп’ютерного моделювання найбільш ефективних режимів роботи установки для знезараження води за допомогою розрядів у газових бульках, при яких (режимах) амплітуда імпульсів напруги на вузлі обробки та на шарі води, що обробляється, не менше амплітуди напруги безпосередньо після комутуючого розрядника. Методика. Для досягнення поставленої мети ми використовували комп’ютерне моделювання за допомогою Micro-Cap 10. Ми використовували дві різні електричні схеми, що моделюють роботу експериментальної установки в двох різних режимах: в режимі з електричною міцністю, що відновлюється, розрядного проміжку в газовій бульці між двома сусідніми імпульсами напруги на розрядному вузлі та у режимі без відновлення цієї електричної міцності. При комп’ютерному моделюванні варіювалися такі фактори: максимальний крок при моделюванні, індуктивності, ємності, активні опори, хвильовий опір довгої лінії, час затримки спрацьовування розрядника, що моделює розрядний проміжок у газовому міхурі. Результати. Комп’ютерне моделювання показало, що для збільшення амплітуди напруги на вузлі обробки і на шарі води, що обробляється, слід зменшувати навантажувальну ємність – ємність шару води у вузлі обробки до 10 пФ і менше, збільшувати активний опір шару води до 500 Ом і більше. Важливим чинником збільшення напруги і напруженості електричного поля в розрядному вузлі і, отже, збільшення ефективності знезараження оброблюваної води є час затримки розряду в газових бульбашках. Найбільш раціональний час затримки спрацьовування розрядника, яким є зазор у газовій бульці всередині води, у розглянутих умовах становить 4-5 нс. Саме при такому часі затримки амплітуда імпульсів напруги на вузлі знезаражувальної обробки води і на шарі оброблюваної води є максимальною за інших рівних умов і істотно перевищує амплітуду напруги безпосередньо після основного високовольтного розрядника, що комутує енергію з високовольтного ємнісного нагромаджувача у вузол обробки. Наукова новизна. За допомогою комп’ютерного моделювання показана можливість підвищення напруги на розрядному вузлі експериментальної установки на 35 % без збільшення напруги джерела живлення, що забезпечує більш ефективне мікробіологічне знезараження води за допомогою наносекундних розрядів у газових бульбашках за малих питомих витрат енергії. Практична значущість. Отримані результати комп’ютерного моделювання підтверджують перспективу промислового застосування установок з використанням наносекундних розрядів для знезараження та очищення стічних вод, басейнів та доочищення водопровідної води. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2024-01-01 Article Article Peer-reviewed Article application/pdf http://eie.khpi.edu.ua/article/view/293402 10.20998/2074-272X.2024.1.06 Electrical Engineering & Electromechanics; No. 1 (2024); 43-50 Электротехника и Электромеханика; № 1 (2024); 43-50 Електротехніка і Електромеханіка; № 1 (2024); 43-50 2309-3404 2074-272X en http://eie.khpi.edu.ua/article/view/293402/286225 Copyright (c) 2023 M. I. Boiko, K. S. Tatkova http://creativecommons.org/licenses/by-nc/4.0