Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load

Problem. One of the acute problems that needs to be solved when performing repair work under voltage on power transmission lines (PTLs) is the protection of workers’ health from high-intensity electromagnetic fields. Goal. The purpose of the work is to develop the methodological foundations for the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2024
Hauptverfasser: Rozov, V. Yu., Reutskiy, S. Yu., Kundius, K. D.
Format: Artikel
Sprache:English
Ukrainian
Veröffentlicht: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2024
Schlagworte:
Online Zugang:http://eie.khpi.edu.ua/article/view/306635
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-306635
record_format ojs
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2024-06-21T04:45:20Z
collection OJS
language English
Ukrainian
topic high-voltage power line
work on wires without removing the voltage
reducing the magnetic field
spellingShingle high-voltage power line
work on wires without removing the voltage
reducing the magnetic field
Rozov, V. Yu.
Reutskiy, S. Yu.
Kundius, K. D.
Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
topic_facet high-voltage power line
work on wires without removing the voltage
reducing the magnetic field
високовольтна лінія електропередачі
роботи без зняття напруги
зменшення магнітного поля
format Article
author Rozov, V. Yu.
Reutskiy, S. Yu.
Kundius, K. D.
author_facet Rozov, V. Yu.
Reutskiy, S. Yu.
Kundius, K. D.
author_sort Rozov, V. Yu.
title Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
title_short Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
title_full Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
title_fullStr Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
title_full_unstemmed Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load
title_sort protection of workers against the magnetic field of 330-750 kv overhead power lines when performing work without removing the voltage under load
title_alt Захист працівників від магнітного поля повітряних ліній електропередачі 330-750 кВ при виконанні робіт без зняття напруги під навантаженням
description Problem. One of the acute problems that needs to be solved when performing repair work under voltage on power transmission lines (PTLs) is the protection of workers’ health from high-intensity electromagnetic fields. Goal. The purpose of the work is to develop the methodological foundations for the protection of workers from the magnetic field (MF) of the 330-750 kV PTL during repairing work without removing the voltage and under loading. Methodology. A methodology for calculating the maximum allowable PTL loading factor has been developed. It limits the flux density of the MF in the working area of the power transmission line to the maximum permissible level of sanitary standards for the given period of work at the potential and the minimum thickness of the protective layer between the wires and the worker’s body. Originality. Methodological principles for protecting workers from magnetic fields have been created. They are based on the joint use of the developed method of mode load minimization and the method of increasing the working distance, and the developed method of calculating the maximum allowable loading factor of PTLs. Practical value. The graphic dependence of the maximum allowable loading factor of the PTL is proposed as a function of the required working time and the thickness of the introduced additional protective layer between the wires and the body of the worker. It allows one quickly determines the maximum allowable loading factors to conform the accepted limit-allowable normative level of flux density of MF for various types of PTLs 330-750 kV. References 45, tables 1, figures 10.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2024
url http://eie.khpi.edu.ua/article/view/306635
work_keys_str_mv AT rozovvyu protectionofworkersagainstthemagneticfieldof330750kvoverheadpowerlineswhenperformingworkwithoutremovingthevoltageunderload
AT reutskiysyu protectionofworkersagainstthemagneticfieldof330750kvoverheadpowerlineswhenperformingworkwithoutremovingthevoltageunderload
AT kundiuskd protectionofworkersagainstthemagneticfieldof330750kvoverheadpowerlineswhenperformingworkwithoutremovingthevoltageunderload
AT rozovvyu zahistpracívnikívvídmagnítnogopolâpovítrânihlíníjelektroperedačí330750kvprivikonannírobítbezznâttânaprugipídnavantažennâm
AT reutskiysyu zahistpracívnikívvídmagnítnogopolâpovítrânihlíníjelektroperedačí330750kvprivikonannírobítbezznâttânaprugipídnavantažennâm
AT kundiuskd zahistpracívnikívvídmagnítnogopolâpovítrânihlíníjelektroperedačí330750kvprivikonannírobítbezznâttânaprugipídnavantažennâm
first_indexed 2025-07-17T11:50:19Z
last_indexed 2025-07-17T11:50:19Z
_version_ 1850412180663435264
spelling eiekhpieduua-article-3066352024-06-21T04:45:20Z Protection of workers against the magnetic field of 330-750 kV overhead power lines when performing work without removing the voltage under load Захист працівників від магнітного поля повітряних ліній електропередачі 330-750 кВ при виконанні робіт без зняття напруги під навантаженням Rozov, V. Yu. Reutskiy, S. Yu. Kundius, K. D. high-voltage power line work on wires without removing the voltage reducing the magnetic field високовольтна лінія електропередачі роботи без зняття напруги зменшення магнітного поля Problem. One of the acute problems that needs to be solved when performing repair work under voltage on power transmission lines (PTLs) is the protection of workers’ health from high-intensity electromagnetic fields. Goal. The purpose of the work is to develop the methodological foundations for the protection of workers from the magnetic field (MF) of the 330-750 kV PTL during repairing work without removing the voltage and under loading. Methodology. A methodology for calculating the maximum allowable PTL loading factor has been developed. It limits the flux density of the MF in the working area of the power transmission line to the maximum permissible level of sanitary standards for the given period of work at the potential and the minimum thickness of the protective layer between the wires and the worker’s body. Originality. Methodological principles for protecting workers from magnetic fields have been created. They are based on the joint use of the developed method of mode load minimization and the method of increasing the working distance, and the developed method of calculating the maximum allowable loading factor of PTLs. Practical value. The graphic dependence of the maximum allowable loading factor of the PTL is proposed as a function of the required working time and the thickness of the introduced additional protective layer between the wires and the body of the worker. It allows one quickly determines the maximum allowable loading factors to conform the accepted limit-allowable normative level of flux density of MF for various types of PTLs 330-750 kV. References 45, tables 1, figures 10. Проблема. Однією із гострих проблем, що потребує вирішення при виконанні ремонтних робіт під напругою на лініях електропередачі (ЛЕП), є захист здоров’я працівників від електромагнітного поля високої інтенсивності. Мета. Метою роботи є розроблення методологічних основ захисту працівників від магнітного поля (МП) ЛЕП 330-750 кВ при виконанні ремонтних робіт без зняття напруги і під навантаженням. Методика. Розроблено методику розрахунку гранично допустимого коефіцієнту навантаження ЛЕП, який обмежує індукцію МП в робочій зоні ЛЕП до гранично допустимого рівня санітарних норм при заданих терміні робіт на потенціалі і мінімальній товщині захисного слою між проводами та тілом працівника. Наукова новизна. Створені методологічні засади захисту працівників від МП, що ґрунтуються на сумісному використанні розроблених методу режимної мінімізації навантаження і методу збільшення робочої дистанції, та розробленої методики розрахунку гранично допустимого коефіцієнту навантаження ЛЕП. Практична значимість Запропоновані графічні залежності гранично допустимого коефіцієнту навантаження ЛЕП в функції від необхідного часу роботи та товщини введеного додаткового захисного слою між проводами та тілом працівника, що при прийнятому гранично допустимому нормативному рівні індукції МП дозволяє оперативно визначати гранично допустимі коефіцієнти навантаження для різних типів ЛЕП 330-750 кВ. Бібл. 45, табл. 1, рис. 10. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2024-06-21 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/306635 10.20998/2074-272X.2024.4.09 Electrical Engineering & Electromechanics; No. 4 (2024); 70-78 Электротехника и Электромеханика; № 4 (2024); 70-78 Електротехніка і Електромеханіка; № 4 (2024); 70-78 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/306635/298017 http://eie.khpi.edu.ua/article/view/306635/298019 Copyright (c) 2024 V. Yu. Rozov, S. Yu. Reutskiy, K. D. Kundius http://creativecommons.org/licenses/by-nc/4.0