Magnetic field of electrical heating cable systems of the floors for residential premises

Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a v...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2024
Автори: Rozov, V. Yu., Reutskiy, S. Yu., Pelevin, D. Ye., Kundius, K. D.
Формат: Стаття
Мова:English
Ukrainian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2024
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/309560
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
Опис
Резюме:Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a verified methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises, and assessment of compliance of the magnetic field with the normative level. Method. A methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises has been developed. Scientific novelty. Based on Bio-Savar’s law and the principle of superposition, an analytical model of the magnetic field of electric heating cable systems of the floors and its calculation method was created. The magnetic field of the coaxial heating cable is determined, taking into account the value of its maximum eccentricity. The experimentally substantiated correctness of the obtained theoretical statements, which is confirmed by their coincidence with the results of the experiment with a spread of less than 7 %. Practical significance. A verified methodology for calculating the magnetic field of electric heating cable systems of the floors was proposed and an assessment of compliance of their magnetic flux density with the normative level of 0.5 μT was performed. It is recommended to lay modern two-wire heating cables at a depth of at least 75–100 mm from the floor. With a smaller laying depth, it is recommended to use coaxial heating cables, which have an order of magnitude smaller magnetic field. References 51, tables 1, figures 11.