Magnetic field of electrical heating cable systems of the floors for residential premises
Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a v...
Gespeichert in:
| Datum: | 2024 |
|---|---|
| Hauptverfasser: | , , , |
| Format: | Artikel |
| Sprache: | English Ukrainian |
| Veröffentlicht: |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
2024
|
| Schlagworte: | |
| Online Zugang: | http://eie.khpi.edu.ua/article/view/309560 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Electrical Engineering & Electromechanics |
Institution
Electrical Engineering & Electromechanics| id |
eiekhpieduua-article-309560 |
|---|---|
| record_format |
ojs |
| institution |
Electrical Engineering & Electromechanics |
| baseUrl_str |
|
| datestamp_date |
2024-08-19T17:45:12Z |
| collection |
OJS |
| language |
English Ukrainian |
| topic |
electric heating cable systems of the floors magnetic field modeling and measurement assessment of compliance with the normative level |
| spellingShingle |
electric heating cable systems of the floors magnetic field modeling and measurement assessment of compliance with the normative level Rozov, V. Yu. Reutskiy, S. Yu. Pelevin, D. Ye. Kundius, K. D. Magnetic field of electrical heating cable systems of the floors for residential premises |
| topic_facet |
кабельні системи електрообігріву підлог магнітне поле моделювання та вимірювання оцінка відповідності нормативному рівню electric heating cable systems of the floors magnetic field modeling and measurement assessment of compliance with the normative level |
| format |
Article |
| author |
Rozov, V. Yu. Reutskiy, S. Yu. Pelevin, D. Ye. Kundius, K. D. |
| author_facet |
Rozov, V. Yu. Reutskiy, S. Yu. Pelevin, D. Ye. Kundius, K. D. |
| author_sort |
Rozov, V. Yu. |
| title |
Magnetic field of electrical heating cable systems of the floors for residential premises |
| title_short |
Magnetic field of electrical heating cable systems of the floors for residential premises |
| title_full |
Magnetic field of electrical heating cable systems of the floors for residential premises |
| title_fullStr |
Magnetic field of electrical heating cable systems of the floors for residential premises |
| title_full_unstemmed |
Magnetic field of electrical heating cable systems of the floors for residential premises |
| title_sort |
magnetic field of electrical heating cable systems of the floors for residential premises |
| title_alt |
Магнітне поле кабельних систем електрообігріву підлог житлових приміщень |
| description |
Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a verified methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises, and assessment of compliance of the magnetic field with the normative level. Method. A methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises has been developed. Scientific novelty. Based on Bio-Savar’s law and the principle of superposition, an analytical model of the magnetic field of electric heating cable systems of the floors and its calculation method was created. The magnetic field of the coaxial heating cable is determined, taking into account the value of its maximum eccentricity. The experimentally substantiated correctness of the obtained theoretical statements, which is confirmed by their coincidence with the results of the experiment with a spread of less than 7 %. Practical significance. A verified methodology for calculating the magnetic field of electric heating cable systems of the floors was proposed and an assessment of compliance of their magnetic flux density with the normative level of 0.5 μT was performed. It is recommended to lay modern two-wire heating cables at a depth of at least 75–100 mm from the floor. With a smaller laying depth, it is recommended to use coaxial heating cables, which have an order of magnitude smaller magnetic field. References 51, tables 1, figures 11. |
| publisher |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine |
| publishDate |
2024 |
| url |
http://eie.khpi.edu.ua/article/view/309560 |
| work_keys_str_mv |
AT rozovvyu magneticfieldofelectricalheatingcablesystemsofthefloorsforresidentialpremises AT reutskiysyu magneticfieldofelectricalheatingcablesystemsofthefloorsforresidentialpremises AT pelevindye magneticfieldofelectricalheatingcablesystemsofthefloorsforresidentialpremises AT kundiuskd magneticfieldofelectricalheatingcablesystemsofthefloorsforresidentialpremises AT rozovvyu magnítnepolekabelʹnihsistemelektroobígrívupídlogžitlovihprimíŝenʹ AT reutskiysyu magnítnepolekabelʹnihsistemelektroobígrívupídlogžitlovihprimíŝenʹ AT pelevindye magnítnepolekabelʹnihsistemelektroobígrívupídlogžitlovihprimíŝenʹ AT kundiuskd magnítnepolekabelʹnihsistemelektroobígrívupídlogžitlovihprimíŝenʹ |
| first_indexed |
2025-07-17T11:50:24Z |
| last_indexed |
2025-07-17T11:50:24Z |
| _version_ |
1850412190039801856 |
| spelling |
eiekhpieduua-article-3095602024-08-19T17:45:12Z Magnetic field of electrical heating cable systems of the floors for residential premises Магнітне поле кабельних систем електрообігріву підлог житлових приміщень Rozov, V. Yu. Reutskiy, S. Yu. Pelevin, D. Ye. Kundius, K. D. кабельні системи електрообігріву підлог магнітне поле моделювання та вимірювання оцінка відповідності нормативному рівню electric heating cable systems of the floors magnetic field modeling and measurement assessment of compliance with the normative level Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a verified methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises, and assessment of compliance of the magnetic field with the normative level. Method. A methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises has been developed. Scientific novelty. Based on Bio-Savar’s law and the principle of superposition, an analytical model of the magnetic field of electric heating cable systems of the floors and its calculation method was created. The magnetic field of the coaxial heating cable is determined, taking into account the value of its maximum eccentricity. The experimentally substantiated correctness of the obtained theoretical statements, which is confirmed by their coincidence with the results of the experiment with a spread of less than 7 %. Practical significance. A verified methodology for calculating the magnetic field of electric heating cable systems of the floors was proposed and an assessment of compliance of their magnetic flux density with the normative level of 0.5 μT was performed. It is recommended to lay modern two-wire heating cables at a depth of at least 75–100 mm from the floor. With a smaller laying depth, it is recommended to use coaxial heating cables, which have an order of magnitude smaller magnetic field. References 51, tables 1, figures 11. Проблема. Для ефективного захисту здоров’я населення від магнітного поля кабельних систем електрообігріву підлог, необхідно його зменшення до безпечного рівня. Однак це потребує ретельного вивчення магнітного поля. Метою роботи є розробка математичної моделі і верифікованої методики розрахунку магнітного поля кабельних систем електрообігріву підлог житлових приміщень, та оцінка відповідності магнітного поля нормативному рівню. Методика. Розроблено методику розрахунку магнітного поля кабельних систем електрообігріву підлог в житлових приміщеннях. Наукова новизна. На основі закону Біо-Савара та принципу суперпозиції створено аналітичну модель магнітного поля кабельних систем електрообігріву підлог та методику його розрахунку. Визначено магнітне поле коаксіального нагрівального кабелю з урахуванням величини його максимального ексцентриситету. Експериментально обґрунтована коректність отриманих теоретичних положень, яка підтверджена їх співпадінням із результатами експерименту з розкидом менше 7 %. Практична значимість. Запропоновано верифіковану методику розрахунку магнітного поля кабельних систем електрообігріву підлог і виконано оцінку відповідності індукції їх магнітного поля нормативному рівню 0,5 мкТл. Рекомендовано прокладати сучасні двожильні нагрівальні кабелі на глибині не менше 0,075–0,1 м від підлоги. При меншій глибини прокладання рекомендовано використовувати коаксіальні нагрівальні кабелі, що мають на порядок менше магнітне поле. Бібл. 51, табл. 1, рис. 11. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2024-08-19 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/309560 10.20998/2074-272X.2024.5.07 Electrical Engineering & Electromechanics; No. 5 (2024); 48-57 Электротехника и Электромеханика; № 5 (2024); 48-57 Електротехніка і Електромеханіка; № 5 (2024); 48-57 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/309560/301041 http://eie.khpi.edu.ua/article/view/309560/301042 Copyright (c) 2024 V. Yu. Rozov, S. Yu. Reutskiy, D. Ye. Pelevin, K. D. Kundius http://creativecommons.org/licenses/by-nc/4.0 |