Improved speed sensorless control for induction motor drives using rotor flux angle estimation
Introduction. In the typical field-oriented control (FOC) method, the variation of machine resistance is not considered when calculating the rotor flux angle. This omission affects the accuracy of the control method during motor operation, leading to potential performance degradation. Problem. Negle...
Gespeichert in:
| Datum: | 2025 |
|---|---|
| Hauptverfasser: | Tran, C. D., Kuchar, M., Nguyen, P. D. |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
2025
|
| Schlagworte: | |
| Online Zugang: | http://eie.khpi.edu.ua/article/view/323045 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Electrical Engineering & Electromechanics |
Institution
Electrical Engineering & ElectromechanicsÄhnliche Einträge
-
Implementation of a new flux rotor based on model reference adaptive system for sensorless direct torque control modified for induction motor
von: Saifi, R.
Veröffentlicht: (2023) -
Research for an enhanced fault-tolerant solution against the current sensor fault types in induction motor drives
von: Tran, C. D., et al.
Veröffentlicht: (2024) -
Model reference adaptive backstepping control of double star induction machine with extended Kalman sensorless control
von: Chaabane, H., et al.
Veröffentlicht: (2022) -
Model reference adaptive system speed estimator based on type-1 and type-2 fuzzy logic sensorless control of electrical vehicle with electrical differential
von: Khemis, A., et al.
Veröffentlicht: (2023) -
A mathematical model of an induction motor with the stator and rotor unsymmetry
von: Chaban, V. Y., et al.
Veröffentlicht: (2012)