SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION

The results of measurements of the contact potential difference of not shielded and shielded samples of cables with twisted pair without shielded chamber, inside a shielded non-grounded and grounded camera are presented. Inspections carrying out in a grounded chamber are more effective in the case o...

Full description

Saved in:
Bibliographic Details
Date:2014
Main Authors: Bezprozvannych, G. V., Boyko, A. N.
Format: Article
Language:Russian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.10
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-34793
record_format ojs
spelling eiekhpieduua-article-347932017-12-27T16:20:13Z SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION ОБОСНОВАНИЕ И ОБЕСПЕЧЕНИЕ ТЕХНОЛОГИЧЕСКИХ ПОКАЗАТЕЛЕЙ ТРИБОЭЛЕКТРИЧЕСКОГО МЕТОДА КОНТРОЛЯ КАБЕЛЕЙ С ПОЛИМЕРНОЙ ИЗОЛЯЦИЕЙ ОБОСНОВАНИЕ И ОБЕСПЕЧЕНИЕ ТЕХНОЛОГИЧЕСКИХ ПОКАЗАТЕЛЕЙ ТРИБОЭЛЕКТРИЧЕСКОГО МЕТОДА КОНТРОЛЯ КАБЕЛЕЙ С ПОЛИМЕРНОЙ ИЗОЛЯЦИЕЙ Bezprozvannych, G. V. Boyko, A. N. contact potential difference triboelectrical method cables polymer insulation shielded test chamber electrostatic voltmeter digital voltmeter 621.319 contact potential difference triboelectrical method cables polymer insulation shielded test chamber electrostatic voltmeter digital voltmeter 621.319 contact potential difference triboelectrical method cables polymer insulation shielded test chamber electrostatic voltmeter digital voltmeter 621.319 The results of measurements of the contact potential difference of not shielded and shielded samples of cables with twisted pair without shielded chamber, inside a shielded non-grounded and grounded camera are presented. Inspections carrying out in a grounded chamber are more effective in the case of shielded cables. It is shown that utilization of an electrostatic voltmeter with higher sensitivity in comparison with digital voltmeter leads to registration as individual own internal noises of the cable as external ones. The coefficients of correlation between the results of measurements of the contact potential difference of the power cable by electrostatic voltmeter and by digital multimeter are determined. Представлены результаты измерений контактной разницы потенциалов неэкранированного и экранированного образцов кабелей с витыми парами без экранированной камеры, в экранированной не заземленной и заземленной камере. Проведение обследований в заземленной камере более эффективно в случае экранированных кабелей. Показано, что применение электростатического вольтметра с более высокой чувствительностью в сравнении с цифровым вольтметром приводит к регистрации, как собственных внутренних индивидуальных шумов кабеля, так и внешних. Определены коэффициенты корреляции между результатами измерений контактной разности потенциалов силового кабеля электростатическим вольтметром и цифровым мультиметром. Представлено результати вимірів контактної різниці потенціалів неекранованого та екранованого зразків кабелів з витими парами без екранованої камери, в екранованій не заземленій та заземленій камері. Проведення обстеження в заземленій камері більш ефективно у випадку екранованих кабелів. Показано, що застосування електростатичного вольтметру з більш високою чутливістю в порівнянні з цифровим мультиметром призводить до реєстрації як власних внутрішніх індивідуальних шумів кабелю, так і зовнішніх. Визначено коефіцієнти кореляції між результатами вимірів контактної різниці потенціалів силового кабелю електростатичним вольтметром та цифровим мультиметром. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014-12-20 Article Article Peer-reviewed Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.10 10.20998/2074-272X.2014.6.10 Electrical Engineering & Electromechanics; No. 6 (2014); 56-60 Электротехника и Электромеханика; № 6 (2014); 56-60 Електротехніка і Електромеханіка; № 6 (2014); 56-60 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.10/31014 Copyright (c) 2015 G. V. Bezprozvannych, A. N. Boyko https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2017-12-27T16:20:13Z
collection OJS
language Russian
topic contact potential difference
triboelectrical method
cables
polymer insulation
shielded test chamber
electrostatic voltmeter
digital voltmeter
621.319
spellingShingle contact potential difference
triboelectrical method
cables
polymer insulation
shielded test chamber
electrostatic voltmeter
digital voltmeter
621.319
Bezprozvannych, G. V.
Boyko, A. N.
SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
topic_facet contact potential difference
triboelectrical method
cables
polymer insulation
shielded test chamber
electrostatic voltmeter
digital voltmeter
621.319
contact potential difference
triboelectrical method
cables
polymer insulation
shielded test chamber
electrostatic voltmeter
digital voltmeter
621.319
contact potential difference
triboelectrical method
cables
polymer insulation
shielded test chamber
electrostatic voltmeter
digital voltmeter
621.319
format Article
author Bezprozvannych, G. V.
Boyko, A. N.
author_facet Bezprozvannych, G. V.
Boyko, A. N.
author_sort Bezprozvannych, G. V.
title SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
title_short SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
title_full SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
title_fullStr SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
title_full_unstemmed SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
title_sort substantiation and guaranteeing of technological parameters of triboelectrical method of monitoring of cables with polymer insulation
title_alt ОБОСНОВАНИЕ И ОБЕСПЕЧЕНИЕ ТЕХНОЛОГИЧЕСКИХ ПОКАЗАТЕЛЕЙ ТРИБОЭЛЕКТРИЧЕСКОГО МЕТОДА КОНТРОЛЯ КАБЕЛЕЙ С ПОЛИМЕРНОЙ ИЗОЛЯЦИЕЙ
ОБОСНОВАНИЕ И ОБЕСПЕЧЕНИЕ ТЕХНОЛОГИЧЕСКИХ ПОКАЗАТЕЛЕЙ ТРИБОЭЛЕКТРИЧЕСКОГО МЕТОДА КОНТРОЛЯ КАБЕЛЕЙ С ПОЛИМЕРНОЙ ИЗОЛЯЦИЕЙ
description The results of measurements of the contact potential difference of not shielded and shielded samples of cables with twisted pair without shielded chamber, inside a shielded non-grounded and grounded camera are presented. Inspections carrying out in a grounded chamber are more effective in the case of shielded cables. It is shown that utilization of an electrostatic voltmeter with higher sensitivity in comparison with digital voltmeter leads to registration as individual own internal noises of the cable as external ones. The coefficients of correlation between the results of measurements of the contact potential difference of the power cable by electrostatic voltmeter and by digital multimeter are determined.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2014
url http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.10
work_keys_str_mv AT bezprozvannychgv substantiationandguaranteeingoftechnologicalparametersoftriboelectricalmethodofmonitoringofcableswithpolymerinsulation
AT boykoan substantiationandguaranteeingoftechnologicalparametersoftriboelectricalmethodofmonitoringofcableswithpolymerinsulation
AT bezprozvannychgv obosnovanieiobespečenietehnologičeskihpokazatelejtriboélektričeskogometodakontrolâkabelejspolimernojizolâciej
AT boykoan obosnovanieiobespečenietehnologičeskihpokazatelejtriboélektričeskogometodakontrolâkabelejspolimernojizolâciej
first_indexed 2025-07-17T11:45:04Z
last_indexed 2025-07-17T11:45:04Z
_version_ 1850411238836666368