SUBSTANTIATION AND GUARANTEEING OF TECHNOLOGICAL PARAMETERS OF TRIBOELECTRICAL METHOD OF MONITORING OF CABLES WITH POLYMER INSULATION
The results of measurements of the contact potential difference of not shielded and shielded samples of cables with twisted pair without shielded chamber, inside a shielded non-grounded and grounded camera are presented. Inspections carrying out in a grounded chamber are more effective in the case o...