ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which...
Збережено в:
| Дата: | 2014 |
|---|---|
| Автори: | , |
| Формат: | Стаття |
| Мова: | Russian |
| Опубліковано: |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
2014
|
| Теми: | |
| Онлайн доступ: | http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.11 |
| Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
| Назва журналу: | Electrical Engineering & Electromechanics |
Репозитарії
Electrical Engineering & Electromechanics| id |
eiekhpieduua-article-34794 |
|---|---|
| record_format |
ojs |
| spelling |
eiekhpieduua-article-347942017-12-27T16:20:13Z ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION АНАЛИЗ СТРУКТУРЫ ПОЛЯ И ОБОСНОВАНИЕ НАПРЯЖЕНИЙ ДИАГНОСТИКИ ПО ЧАСТИЧНЫМ РАЗРЯДАМ ИЗОЛЯЦИИ ЭКРАНИРОВАННЫХ ВИТЫХ ПАР АНАЛИЗ СТРУКТУРЫ ПОЛЯ И ОБОСНОВАНИЕ НАПРЯЖЕНИЙ ДИАГНОСТИКИ ПО ЧАСТИЧНЫМ РАЗРЯДАМ ИЗОЛЯЦИИ ЭКРАНИРОВАННЫХ ВИТЫХ ПАР Bezprozvannych, G. V. Kyessayev, A. G. partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which are used for technical diagnostics of insulation. Выполнен анализ электростатического поля витой экранированной пары кабеля при разных видах испытательного напряжения: симметричное разнополярное, однополярное и несимметричное. Выбор напряжения влияет на местоположение наиболее вероятного места возникновения частичных разрядов, фазовые характеристики которых используются для технической диагностики изоляции. Виконано аналіз електростатичного поля витої екранованої пари кабелю при різних видах випробувальної напруги: симетричній рiзнополярнiй, однополярнiй i несиметричній. Вибір напруги впливає на місцеположення найбільш вiрогiдного місця виникнення часткового розряду, фазові характеристики яких застосовуються для технічної діагностики iзоляцiї. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2014-12-20 Article Article Peer-reviewed Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.11 10.20998/2074-272X.2014.6.11 Electrical Engineering & Electromechanics; No. 6 (2014); 61-65 Электротехника и Электромеханика; № 6 (2014); 61-65 Електротехніка і Електромеханіка; № 6 (2014); 61-65 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.11/31015 Copyright (c) 2015 G. V. Bezprozvannych, A. G. Kyessayev https://creativecommons.org/licenses/by-nc/4.0 |
| institution |
Electrical Engineering & Electromechanics |
| baseUrl_str |
|
| datestamp_date |
2017-12-27T16:20:13Z |
| collection |
OJS |
| language |
Russian |
| topic |
partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 |
| spellingShingle |
partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 Bezprozvannych, G. V. Kyessayev, A. G. ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| topic_facet |
partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics 621.319 |
| format |
Article |
| author |
Bezprozvannych, G. V. Kyessayev, A. G. |
| author_facet |
Bezprozvannych, G. V. Kyessayev, A. G. |
| author_sort |
Bezprozvannych, G. V. |
| title |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| title_short |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| title_full |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| title_fullStr |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| title_full_unstemmed |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
| title_sort |
analysis of field structure and justification of voltages of diagnostics by partial discharges of shielded twisted pairs insulation |
| title_alt |
АНАЛИЗ СТРУКТУРЫ ПОЛЯ И ОБОСНОВАНИЕ НАПРЯЖЕНИЙ ДИАГНОСТИКИ ПО ЧАСТИЧНЫМ РАЗРЯДАМ ИЗОЛЯЦИИ ЭКРАНИРОВАННЫХ ВИТЫХ ПАР АНАЛИЗ СТРУКТУРЫ ПОЛЯ И ОБОСНОВАНИЕ НАПРЯЖЕНИЙ ДИАГНОСТИКИ ПО ЧАСТИЧНЫМ РАЗРЯДАМ ИЗОЛЯЦИИ ЭКРАНИРОВАННЫХ ВИТЫХ ПАР |
| description |
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which are used for technical diagnostics of insulation. |
| publisher |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine |
| publishDate |
2014 |
| url |
http://eie.khpi.edu.ua/article/view/2074-272X.2014.6.11 |
| work_keys_str_mv |
AT bezprozvannychgv analysisoffieldstructureandjustificationofvoltagesofdiagnosticsbypartialdischargesofshieldedtwistedpairsinsulation AT kyessayevag analysisoffieldstructureandjustificationofvoltagesofdiagnosticsbypartialdischargesofshieldedtwistedpairsinsulation AT bezprozvannychgv analizstrukturypolâiobosnovanienaprâženijdiagnostikipočastičnymrazrâdamizolâciiékranirovannyhvityhpar AT kyessayevag analizstrukturypolâiobosnovanienaprâženijdiagnostikipočastičnymrazrâdamizolâciiékranirovannyhvityhpar |
| first_indexed |
2025-07-17T11:45:04Z |
| last_indexed |
2025-07-17T11:45:04Z |
| _version_ |
1850411241760096256 |