ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL

Refinement of the aging integral formula is proposed. A computer model of insulation wearing out is developed using refined formula. Computer simulation of power transformer insulation wearing out over the next ten years of life is carried out.

Saved in:
Bibliographic Details
Date:2015
Main Author: Vasilevskij, V. V.
Format: Article
Language:Russian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2015
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2015.1.03
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-38292
record_format ojs
spelling eiekhpieduua-article-382922016-11-22T17:12:29Z ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL ОЦЕНКА РАСХОДА РЕСУРСА БУМАЖНОЙ ИЗОЛЯЦИИ СИЛОВОГО МАСЛОНАПОЛНЕННОГО ТРАНСФОРМАТОРА С ПОМОЩЬЮ УТОЧНЕННОЙ ФОРМУЛЫ ИНТЕГРАЛА СТАРЕНИЯ ОЦЕНКА РАСХОДА РЕСУРСА БУМАЖНОЙ ИЗОЛЯЦИИ СИЛОВОГО МАСЛОНАПОЛНЕННОГО ТРАНСФОРМАТОРА С ПОМОЩЬЮ УТОЧНЕННОЙ ФОРМУЛЫ ИНТЕГРАЛА СТАРЕНИЯ Vasilevskij, V. V. aging integral power transformer insulation wearing out prognosis models of technical condition and operating factors 648.3.048.1 интеграл старения силовой трансформатор износ изоляции прогноз модели технического состояния и факторов эксплуатации 648.3.048.1 інтеграл старіння силовий трансформатор знос ізоляції прогноз моделі технічного стану та факторів експлуатації 648.3.048.1 Refinement of the aging integral formula is proposed. A computer model of insulation wearing out is developed using refined formula. Computer simulation of power transformer insulation wearing out over the next ten years of life is carried out. Предложено уточнение формулы интеграла старения. Разработана компьютерная модель износа изоляции с использованием уточненной формулы. Выполнено моделирование износа изоляции силового трансформатора в течение следующих десяти лет эксплуатации. Запропоновано уточнення формули інтегралу старіння. Розроблено комп'ютерну модель зносу ізоляції з використанням уточненої формули. Виконано моделювання зносу ізоляції потужного трансформатору впродовж наступних десяти років експлуатації. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2015-02-27 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2015.1.03 10.20998/2074-272X.2015.1.03 Electrical Engineering & Electromechanics; No. 1 (2015); 16-19 Электротехника и Электромеханика; № 1 (2015); 16-19 Електротехніка і Електромеханіка; № 1 (2015); 16-19 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2015.1.03/34655 Copyright (c) 2015 V. V. Vasilevskij https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2016-11-22T17:12:29Z
collection OJS
language Russian
topic aging integral
power transformer
insulation wearing out
prognosis
models of technical condition and operating factors
648.3.048.1
spellingShingle aging integral
power transformer
insulation wearing out
prognosis
models of technical condition and operating factors
648.3.048.1
Vasilevskij, V. V.
ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
topic_facet aging integral
power transformer
insulation wearing out
prognosis
models of technical condition and operating factors
648.3.048.1
интеграл старения
силовой трансформатор
износ изоляции
прогноз
модели технического состояния и факторов эксплуатации
648.3.048.1
інтеграл старіння
силовий трансформатор
знос ізоляції
прогноз
моделі технічного стану та факторів експлуатації
648.3.048.1
format Article
author Vasilevskij, V. V.
author_facet Vasilevskij, V. V.
author_sort Vasilevskij, V. V.
title ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
title_short ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
title_full ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
title_fullStr ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
title_full_unstemmed ASSESSMENT OF THE RESOURCE CONSUMPTION OF OIL-FILLED POWER TRANSFORMER PAPER INSULATION BASED ON UPDATED AGING INTEGRAL
title_sort assessment of the resource consumption of oil-filled power transformer paper insulation based on updated aging integral
title_alt ОЦЕНКА РАСХОДА РЕСУРСА БУМАЖНОЙ ИЗОЛЯЦИИ СИЛОВОГО МАСЛОНАПОЛНЕННОГО ТРАНСФОРМАТОРА С ПОМОЩЬЮ УТОЧНЕННОЙ ФОРМУЛЫ ИНТЕГРАЛА СТАРЕНИЯ
ОЦЕНКА РАСХОДА РЕСУРСА БУМАЖНОЙ ИЗОЛЯЦИИ СИЛОВОГО МАСЛОНАПОЛНЕННОГО ТРАНСФОРМАТОРА С ПОМОЩЬЮ УТОЧНЕННОЙ ФОРМУЛЫ ИНТЕГРАЛА СТАРЕНИЯ
description Refinement of the aging integral formula is proposed. A computer model of insulation wearing out is developed using refined formula. Computer simulation of power transformer insulation wearing out over the next ten years of life is carried out.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2015
url http://eie.khpi.edu.ua/article/view/2074-272X.2015.1.03
work_keys_str_mv AT vasilevskijvv assessmentoftheresourceconsumptionofoilfilledpowertransformerpaperinsulationbasedonupdatedagingintegral
AT vasilevskijvv ocenkarashodaresursabumažnojizolâciisilovogomaslonapolnennogotransformatoraspomoŝʹûutočnennojformulyintegralastareniâ
first_indexed 2025-07-17T11:45:06Z
last_indexed 2025-07-17T11:45:06Z
_version_ 1850411253910994944