COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE

Purpose. Three-phase energy supply system with a symmetrical resistive load operates in mode with the highest possible efficiency in a case of zero instantaneous reactive power and the absence of pulsations instantaneous active power. When load parameters are changed, three-phase energy supply syste...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2015
Автори: Zhemerov, George G., Tugay, D. V.
Формат: Стаття
Мова:Russian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2015
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2015.4.05
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-48730
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language Russian
topic energy supply system
power additional losses
the minimum possible losses
Matlab-model of three-phase energy supply system
621.3
система электроснабжения
мощность дополнительных потерь
минимально возможные потери
Matlab-модель трехфазной системы электроснабжения
621.3
система електропостачання
потужність додаткових втрат
мінімально можливі втрати
Matlab-модель системи електропостачання
621.3
spellingShingle energy supply system
power additional losses
the minimum possible losses
Matlab-model of three-phase energy supply system
621.3
система электроснабжения
мощность дополнительных потерь
минимально возможные потери
Matlab-модель трехфазной системы электроснабжения
621.3
система електропостачання
потужність додаткових втрат
мінімально можливі втрати
Matlab-модель системи електропостачання
621.3
Zhemerov, George G.
Tugay, D. V.
COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
topic_facet energy supply system
power additional losses
the minimum possible losses
Matlab-model of three-phase energy supply system
621.3
система электроснабжения
мощность дополнительных потерь
минимально возможные потери
Matlab-модель трехфазной системы электроснабжения
621.3
система електропостачання
потужність додаткових втрат
мінімально можливі втрати
Matlab-модель системи електропостачання
621.3
format Article
author Zhemerov, George G.
Tugay, D. V.
author_facet Zhemerov, George G.
Tugay, D. V.
author_sort Zhemerov, George G.
title COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
title_short COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
title_full COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
title_fullStr COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
title_full_unstemmed COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE
title_sort components of the total power losses in three-phase energy supply systems with symmetric sinusoidal voltage source
title_alt СОСТАВЛЯЮЩИЕ СУММАРНОЙ МОЩНОСТИ ПОТЕРЬ В ТРЕХФАЗНЫХ СИСТЕМАХ ЭЛЕКТРОСНАБЖЕНИЯ ПРИ СИММЕТРИЧНЫХ СИНУСОИДАЛЬНЫХ НАПРЯЖЕНИЯХ ИСТОЧНИКА
СОСТАВЛЯЮЩИЕ СУММАРНОЙ МОЩНОСТИ ПОТЕРЬ В ТРЕХФАЗНЫХ СИСТЕМАХ ЭЛЕКТРОСНАБЖЕНИЯ ПРИ СИММЕТРИЧНЫХ СИНУСОИДАЛЬНЫХ НАПРЯЖЕНИЯХ ИСТОЧНИКА
description Purpose. Three-phase energy supply system with a symmetrical resistive load operates in mode with the highest possible efficiency in a case of zero instantaneous reactive power and the absence of pulsations instantaneous active power. When load parameters are changed, three-phase energy supply system starts to operate in a mode with additional energy losses. The goal of the paper is to determinate the relations between the components of additional losses and their rezone. Methodology. We have applied the modern theory of instantaneous active and reactive power, the graphical filling complex branched energy supply system of simplified design scheme, the theory of electrical circuits, computer Matlab-simulation. Results. We have developed an universal relation to determine the components of total power loss in the three-phase supply systems with symmetrical three-phase sinusoidal voltage source and any possible load. Further verification of this relation in the Matlab-model of three-phase energy supply system shows its high accuracy. Originality. For the first time, we have carried out relation between RMS reactive and RMS active power instantaneous pulsation and the corresponding components of additional losses. Consequently it becomes possible to offer a unique method of weighting evaluation. Practical value. We have developed position for detecting the causes of additional losses in three-phase supply systems with symmetrical sinusoidal voltage source, as well as to substantiate the correctness of the choice of filter-compensating device. We have developed a Matlab-model which allows to investigate the energy efficiency of three-phase energy supply system and to calculate the components of additional power losses of any possible reasons for their occurrence.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2015
url http://eie.khpi.edu.ua/article/view/2074-272X.2015.4.05
work_keys_str_mv AT zhemerovgeorgeg componentsofthetotalpowerlossesinthreephaseenergysupplysystemswithsymmetricsinusoidalvoltagesource
AT tugaydv componentsofthetotalpowerlossesinthreephaseenergysupplysystemswithsymmetricsinusoidalvoltagesource
AT zhemerovgeorgeg sostavlâûŝiesummarnojmoŝnostipoterʹvtrehfaznyhsistemahélektrosnabženiâprisimmetričnyhsinusoidalʹnyhnaprâženiâhistočnika
AT tugaydv sostavlâûŝiesummarnojmoŝnostipoterʹvtrehfaznyhsistemahélektrosnabženiâprisimmetričnyhsinusoidalʹnyhnaprâženiâhistočnika
first_indexed 2024-06-01T14:38:04Z
last_indexed 2024-06-01T14:38:04Z
_version_ 1800669951427608576
spelling eiekhpieduua-article-487302016-05-04T13:28:39Z COMPONENTS OF THE TOTAL POWER LOSSES IN THREE-PHASE ENERGY SUPPLY SYSTEMS WITH SYMMETRIC SINUSOIDAL VOLTAGE SOURCE СОСТАВЛЯЮЩИЕ СУММАРНОЙ МОЩНОСТИ ПОТЕРЬ В ТРЕХФАЗНЫХ СИСТЕМАХ ЭЛЕКТРОСНАБЖЕНИЯ ПРИ СИММЕТРИЧНЫХ СИНУСОИДАЛЬНЫХ НАПРЯЖЕНИЯХ ИСТОЧНИКА СОСТАВЛЯЮЩИЕ СУММАРНОЙ МОЩНОСТИ ПОТЕРЬ В ТРЕХФАЗНЫХ СИСТЕМАХ ЭЛЕКТРОСНАБЖЕНИЯ ПРИ СИММЕТРИЧНЫХ СИНУСОИДАЛЬНЫХ НАПРЯЖЕНИЯХ ИСТОЧНИКА Zhemerov, George G. Tugay, D. V. energy supply system power additional losses the minimum possible losses Matlab-model of three-phase energy supply system 621.3 система электроснабжения мощность дополнительных потерь минимально возможные потери Matlab-модель трехфазной системы электроснабжения 621.3 система електропостачання потужність додаткових втрат мінімально можливі втрати Matlab-модель системи електропостачання 621.3 Purpose. Three-phase energy supply system with a symmetrical resistive load operates in mode with the highest possible efficiency in a case of zero instantaneous reactive power and the absence of pulsations instantaneous active power. When load parameters are changed, three-phase energy supply system starts to operate in a mode with additional energy losses. The goal of the paper is to determinate the relations between the components of additional losses and their rezone. Methodology. We have applied the modern theory of instantaneous active and reactive power, the graphical filling complex branched energy supply system of simplified design scheme, the theory of electrical circuits, computer Matlab-simulation. Results. We have developed an universal relation to determine the components of total power loss in the three-phase supply systems with symmetrical three-phase sinusoidal voltage source and any possible load. Further verification of this relation in the Matlab-model of three-phase energy supply system shows its high accuracy. Originality. For the first time, we have carried out relation between RMS reactive and RMS active power instantaneous pulsation and the corresponding components of additional losses. Consequently it becomes possible to offer a unique method of weighting evaluation. Practical value. We have developed position for detecting the causes of additional losses in three-phase supply systems with symmetrical sinusoidal voltage source, as well as to substantiate the correctness of the choice of filter-compensating device. We have developed a Matlab-model which allows to investigate the energy efficiency of three-phase energy supply system and to calculate the components of additional power losses of any possible reasons for their occurrence. Цель. Оценка энергетической эффективности трехфазных систем электроснабжения при передаче энергии от источника в нагрузку создает необходимость в появлении новых теорий, описывающих причины возникновения дополнительных потерь и их вес в общих суммарных потерях энергии. Целью статьи является разработка удобного математического аппарата для такой оценки и экспериментальная проверка его корректности. Методика. Использовалась современная теория мгновенных активной и реактивной мощностей, графическое замещение сложной разветвленной системы электроснабжения упрощенной расчетной схемой, теория электрических цепей, компьютерное моделирование в программной среде Matlab. Результаты. Получено универсальное расчетное соотношение для определения составляющих суммарной мощности потерь в трехфазных системах электроснабжения с трехфазным симметричным источником синусоидальных напряжений. Проверка полученного соотношения на созданной Matlab-модели трехфазной системы электроснабжения показало высокую точность совпадения теоретических результатов с результатами компьютерного моделирования. Научная новизна. Впервые получено соотношение, связывающее реактивную мощность, а также пульсации мгновенное активной мощности с соответствующими составляющими дополнительных потерь, что позволило предложить уникальный метод весовой оценки последних. Практическое значение. Разработаны положения для детектирования причин возникновения дополнительных потерь в трехфазных системах электроснабжения с симметричным синусоидальным источником напряжения, а также для обоснования корректности выбора фильтро-компенсирующего устройства, при использовании которого система электроснабжения будет работать в режиме с минимальными потерями энергии. Создана компьютерная Matlab-модель, позволяющая исследовать энергетическую эффективность трехфазной системы электроснабжения и рассчитывать составляющие мощности дополнительных потерь при любых возможных причинах их возникновения. Ціль. Оцінка енергетичної ефективності трифазних систем електропостачання при передачі енергії від джерела до навантаження створює необхідність появи нових теорій, що описують причини виникнення додаткових втрат і їх вагу в загальних сумарних втратах енергії. Метою статті є розробка зручного математичного апарату для такої оцінки та експериментальна перевірка його коректності. Методика. Використовувалася сучасна теорія миттєвих активної і реактивної потужностей, графічне заміщення складної розгалуженої системи електропостачання спрощеною розрахункової схемою, теорія електричних кіл, комп'ютерне моделювання в програмному середовищі Matlab. Результати. Отримано універсальне розрахункове співвідношення для визначення складових сумарної потужності втрат в трифазних системах електропостачання з трифазним симетричним джерелом синусоїдальних напруг. Перевірка отриманого співвідношення на створеній Matlab-моделі трифазної системи електропостачання показала високу точність збігу теоретичних результатів з результатами комп'ютерного моделювання. Наукова новизна. Вперше отримано співвідношення, що зв'язує реактивну потужність, а також пульсації миттєве активної потужності з відповідними складовими додаткових втрат, що дозволило запропонувати унікальний метод вагової оцінки останніх. Практичне значення. Розроблено положення для детектування причин виникнення додаткових втрат в трифазних системах електропостачання з симетричним синусоїдальним джерелом напруги, а також для обґрунтування коректності вибору фільтро-компенсуючого пристрою, при використанні якого система електропостачання буде працювати в режимі з мінімальними втратами енергії. Створена Matlab-модель, що дозволяє досліджувати енергетичну ефективність трифазної системи електропостачання і розраховувати складові потужності додаткових втрат при будь-яких можливих причинах їх виникнення. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2015-08-28 Article Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2015.4.05 10.20998/2074-272X.2015.4.05 Electrical Engineering & Electromechanics; No. 4 (2015); 28-34 Электротехника и Электромеханика; № 4 (2015); 28-34 Електротехніка і Електромеханіка; № 4 (2015); 28-34 2309-3404 2074-272X ru http://eie.khpi.edu.ua/article/view/2074-272X.2015.4.05/44947 Copyright (c) 2015 George G. Zhemerov, D. V. Tugay https://creativecommons.org/licenses/by-nc/4.0