MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT

For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage aris...

Full description

Saved in:
Bibliographic Details
Date:2015
Main Authors: Gryb, O. G., Gapon, D. A., Ierusalimova, T. S., Borodin, D. V., Diachenko, A. V.
Format: Article
Language:English
Russian
Published: National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2015
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2015.6.11
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Electrical Engineering & Electromechanics

Institution

Electrical Engineering & Electromechanics
id eiekhpieduua-article-54568
record_format ojs
spelling eiekhpieduua-article-545682016-11-22T17:10:02Z MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT МОНИТОРИНГ КАЧЕСТВА ЭЛЕКТРИЧЕСКОЙ ЭНЕРГИИ НА ВВОДЕ ТЯГОВОЙ ПОДСТАНЦИИ МОНИТОРИНГ КАЧЕСТВА ЭЛЕКТРИЧЕСКОЙ ЭНЕРГИИ НА ВВОДЕ ТЯГОВОЙ ПОДСТАНЦИИ Gryb, O. G. Gapon, D. A. Ierusalimova, T. S. Borodin, D. V. Diachenko, A. V. quality higher harmonics electrical energy substation monitoring losses 621.311 качество высшие гармоники электрическая энергия подстанция мониторинг потери 621.311 качество высшие гармоники электрическая энергия подстанция мониторинг потери 621.311 For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital system for the measurement of electrical energy quality» type of DSMEEQ of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality. Надежность работы системы учета электроэнергии, релейной защиты и автоматики на современных цифровых подстанциях зависит от качества электрической энергии. В настоящее время для повышения надежности работы подстанции необходимо контролировать показатели качества электрической энергии, что позволяет принимать организационные и технические решения по его повышению. Надежность работы системы учета электроэнергии, релейной защиты и автоматики на современных цифровых подстанциях зависит от качества электрической энергии. В настоящее время для повышения надежности работы подстанции необходимо контролировать показатели качества электрической энергии, что позволяет принимать организационные и технические решения по его повышению. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2015-11-26 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2015.6.11 10.20998/2074-272X.2015.6.11 Electrical Engineering & Electromechanics; No. 6 (2015); 61-65 Электротехника и Электромеханика; № 6 (2015); 61-65 Електротехніка і Електромеханіка; № 6 (2015); 61-65 2309-3404 2074-272X en ru http://eie.khpi.edu.ua/article/view/2074-272X.2015.6.11/50958 http://eie.khpi.edu.ua/article/view/2074-272X.2015.6.11/54808 Copyright (c) 2015 O. G. Gryb, D. A. Gapon, T. S. Ierusalimova, D. V. Borodin, A. V. Diachenko https://creativecommons.org/licenses/by-nc/4.0
institution Electrical Engineering & Electromechanics
baseUrl_str
datestamp_date 2016-11-22T17:10:02Z
collection OJS
language English
Russian
topic quality
higher harmonics
electrical energy
substation
monitoring
losses
621.311
spellingShingle quality
higher harmonics
electrical energy
substation
monitoring
losses
621.311
Gryb, O. G.
Gapon, D. A.
Ierusalimova, T. S.
Borodin, D. V.
Diachenko, A. V.
MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
topic_facet quality
higher harmonics
electrical energy
substation
monitoring
losses
621.311
качество
высшие гармоники
электрическая энергия
подстанция
мониторинг
потери
621.311
качество
высшие гармоники
электрическая энергия
подстанция
мониторинг
потери
621.311
format Article
author Gryb, O. G.
Gapon, D. A.
Ierusalimova, T. S.
Borodin, D. V.
Diachenko, A. V.
author_facet Gryb, O. G.
Gapon, D. A.
Ierusalimova, T. S.
Borodin, D. V.
Diachenko, A. V.
author_sort Gryb, O. G.
title MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_short MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_full MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_fullStr MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_full_unstemmed MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT
title_sort monitoring of electrical energy quality on the traction substation input
title_alt МОНИТОРИНГ КАЧЕСТВА ЭЛЕКТРИЧЕСКОЙ ЭНЕРГИИ НА ВВОДЕ ТЯГОВОЙ ПОДСТАНЦИИ
МОНИТОРИНГ КАЧЕСТВА ЭЛЕКТРИЧЕСКОЙ ЭНЕРГИИ НА ВВОДЕ ТЯГОВОЙ ПОДСТАНЦИИ
description For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital system for the measurement of electrical energy quality» type of DSMEEQ of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality.
publisher National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
publishDate 2015
url http://eie.khpi.edu.ua/article/view/2074-272X.2015.6.11
work_keys_str_mv AT grybog monitoringofelectricalenergyqualityonthetractionsubstationinput
AT gaponda monitoringofelectricalenergyqualityonthetractionsubstationinput
AT ierusalimovats monitoringofelectricalenergyqualityonthetractionsubstationinput
AT borodindv monitoringofelectricalenergyqualityonthetractionsubstationinput
AT diachenkoav monitoringofelectricalenergyqualityonthetractionsubstationinput
AT grybog monitoringkačestvaélektričeskojénergiinavvodetâgovojpodstancii
AT gaponda monitoringkačestvaélektričeskojénergiinavvodetâgovojpodstancii
AT ierusalimovats monitoringkačestvaélektričeskojénergiinavvodetâgovojpodstancii
AT borodindv monitoringkačestvaélektričeskojénergiinavvodetâgovojpodstancii
AT diachenkoav monitoringkačestvaélektričeskojénergiinavvodetâgovojpodstancii
first_indexed 2025-07-17T11:45:41Z
last_indexed 2025-07-17T11:45:41Z
_version_ 1850411447076519936