NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD
On the basis of electric field distribution analysis in the volume of a self-regenerative fuse, the active zone of the alkaline metal, which changes its phase state under transition from its condensed state to vapor, is determined. These data are further applied to developing а set of equations for...
Saved in:
| Date: | 2012 |
|---|---|
| Main Authors: | , |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine
2012
|
| Subjects: | |
| Online Access: | http://eie.khpi.edu.ua/article/view/2074-272X.2012.6.11 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Electrical Engineering & Electromechanics |
Institution
Electrical Engineering & Electromechanics| id |
eiekhpieduua-article-6151 |
|---|---|
| record_format |
ojs |
| spelling |
eiekhpieduua-article-61512025-12-02T15:24:13Z NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD МОДЕЛЮВАННЯ РОБОТИ САМОРЕГЕНЕРАТИВНИХ ОБМЕЖУВАЧІВ СТРУМУ З МАЛИМ ЧАСОМ КОМУТАЦІЇ МОДЕЛЮВАННЯ РОБОТИ САМОРЕГЕНЕРАТИВНИХ ОБМЕЖУВАЧІВ СТРУМУ З МАЛИМ ЧАСОМ КОМУТАЦІЇ Dubovenko, K. V. Zotov, O. R. self-regenerative fuse current limiting numerical simulation 621.314 621.314 621.314 On the basis of electric field distribution analysis in the volume of a self-regenerative fuse, the active zone of the alkaline metal, which changes its phase state under transition from its condensed state to vapor, is determined. These data are further applied to developing а set of equations for numerical analysis of the current limiting. Temporal dependences for the fuse and the switch currents, the alkaline metal resistance, and commutation power loss have been obtained. На основании анализа распределения электрического поля в объеме самовосстанавливающегося предохранителя определена активная зона щелочного металла, изменяющего в процессе коммутации. Эти данные применены далее для построения математической модели для численного анализа ограничения тока. Получены временные зависимости для значений тока предохранителя и выключателя, сопротивления щелочного металла, потерь энергии на коммутацию. На основі аналізу розподілу електричного поля в об’ємі саморегенеративного запобіжника визначено активну зону лужного металу, що змінює фазовий стан в процесі комутації. Ці дані застосовано далі для побудови математичної моделі для чисельного аналізу обмеження струму. Отримано часові залежності для значень струму запобіжника і вимикача, опору лужного металу, втрат енергії на комутацію. National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine 2012-12-29 Article Article Peer-reviewed Article application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2012.6.11 10.20998/2074-272X.2012.6.11 Electrical Engineering & Electromechanics; No. 6 (2012); 51-55 Электротехника и Электромеханика; № 6 (2012); 51-55 Електротехніка і Електромеханіка; № 6 (2012); 51-55 2309-3404 2074-272X uk http://eie.khpi.edu.ua/article/view/2074-272X.2012.6.11/5537 Copyright (c) 2015 K. V. Dubovenko, O. R. Zotov https://creativecommons.org/licenses/by-nc/4.0 |
| institution |
Electrical Engineering & Electromechanics |
| baseUrl_str |
|
| datestamp_date |
2025-12-02T15:24:13Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
self-regenerative fuse current limiting numerical simulation 621.314 |
| spellingShingle |
self-regenerative fuse current limiting numerical simulation 621.314 Dubovenko, K. V. Zotov, O. R. NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| topic_facet |
self-regenerative fuse current limiting numerical simulation 621.314 621.314 621.314 |
| format |
Article |
| author |
Dubovenko, K. V. Zotov, O. R. |
| author_facet |
Dubovenko, K. V. Zotov, O. R. |
| author_sort |
Dubovenko, K. V. |
| title |
NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| title_short |
NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| title_full |
NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| title_fullStr |
NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| title_full_unstemmed |
NUMERICAL SIMULATION OF A SELF-REGENERATIVE FUSE OPERATION WITH A SHORT COMMUTATIOM PERIOD |
| title_sort |
numerical simulation of a self-regenerative fuse operation with a short commutatiom period |
| title_alt |
МОДЕЛЮВАННЯ РОБОТИ САМОРЕГЕНЕРАТИВНИХ ОБМЕЖУВАЧІВ СТРУМУ З МАЛИМ ЧАСОМ КОМУТАЦІЇ МОДЕЛЮВАННЯ РОБОТИ САМОРЕГЕНЕРАТИВНИХ ОБМЕЖУВАЧІВ СТРУМУ З МАЛИМ ЧАСОМ КОМУТАЦІЇ |
| description |
On the basis of electric field distribution analysis in the volume of a self-regenerative fuse, the active zone of the alkaline metal, which changes its phase state under transition from its condensed state to vapor, is determined. These data are further applied to developing а set of equations for numerical analysis of the current limiting. Temporal dependences for the fuse and the switch currents, the alkaline metal resistance, and commutation power loss have been obtained. |
| publisher |
National Technical University "Kharkiv Polytechnic Institute" and Аnatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine |
| publishDate |
2012 |
| url |
http://eie.khpi.edu.ua/article/view/2074-272X.2012.6.11 |
| work_keys_str_mv |
AT dubovenkokv numericalsimulationofaselfregenerativefuseoperationwithashortcommutatiomperiod AT zotovor numericalsimulationofaselfregenerativefuseoperationwithashortcommutatiomperiod AT dubovenkokv modelûvannârobotisamoregenerativnihobmežuvačívstrumuzmalimčasomkomutacíí AT zotovor modelûvannârobotisamoregenerativnihobmežuvačívstrumuzmalimčasomkomutacíí |
| first_indexed |
2025-07-17T11:43:54Z |
| last_indexed |
2025-12-02T15:29:06Z |
| _version_ |
1850410896296247296 |