INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR

Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump be...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автори: Lobov, V. I., Lobova, K. V.
Формат: Стаття
Мова:English
Ukrainian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-72018
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
Ukrainian
topic submersible pump
induction motor
thyristor voltage regulator
opening angle of thyristor
intensity setter
start-up
acceleration time
[62-83
621.313.333]-57-592
погружной насос
асинхронный электродвигатель
тиристорный регулятор напряжения
угол открывания тиристоров
задатчик интенсивности
пуск
время ускорения
[62-83
621.313.333]-57-592
заглибний насос
асинхронний електродвигун
тиристорний регулятор напруги
кут відкривання тиристорів
задатчик інтенсивності
пуск
час прискорення
[62-83
621.313.333]-57-592
spellingShingle submersible pump
induction motor
thyristor voltage regulator
opening angle of thyristor
intensity setter
start-up
acceleration time
[62-83
621.313.333]-57-592
погружной насос
асинхронный электродвигатель
тиристорный регулятор напряжения
угол открывания тиристоров
задатчик интенсивности
пуск
время ускорения
[62-83
621.313.333]-57-592
заглибний насос
асинхронний електродвигун
тиристорний регулятор напруги
кут відкривання тиристорів
задатчик інтенсивності
пуск
час прискорення
[62-83
621.313.333]-57-592
Lobov, V. I.
Lobova, K. V.
INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
topic_facet submersible pump
induction motor
thyristor voltage regulator
opening angle of thyristor
intensity setter
start-up
acceleration time
[62-83
621.313.333]-57-592
погружной насос
асинхронный электродвигатель
тиристорный регулятор напряжения
угол открывания тиристоров
задатчик интенсивности
пуск
время ускорения
[62-83
621.313.333]-57-592
заглибний насос
асинхронний електродвигун
тиристорний регулятор напруги
кут відкривання тиристорів
задатчик інтенсивності
пуск
час прискорення
[62-83
621.313.333]-57-592
format Article
author Lobov, V. I.
Lobova, K. V.
author_facet Lobov, V. I.
Lobova, K. V.
author_sort Lobov, V. I.
title INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_short INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_full INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_fullStr INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_full_unstemmed INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR
title_sort intensity setter for a device of smooth start of submersible pump electric motor
title_alt ЗАДАТЧИК ИНТЕНСИВНОСТИ ДЛЯ УСТРОЙСТВА ПЛАВНОГО ПУСКА ЭЛЕКТРОДВИГАТЕЛЯ ПОГРУЖНОГО НАСОСА
ЗАДАТЧИК ІНТЕНСИВНОСТІ ДЛЯ ПРИСТРОЮ ПЛАВНОГО ПУСКУ ЕЛЕКТРОДВИГУНА ЗАГЛИБНОГО НАСОСА
description Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump belongs to the small inertia electric, since it is not significant total moment of inertia, not exceeding two moments of inertia of the motor and static moment on the shaft does not exceed forty percent of the nominal torque. For technical requirements that electric acceleration time should have no less than twenty seconds or more. Office starting modes of electric submersible pumps economically justified using thyristor voltage regulator by forming the dial changes the intensity of the necessary legislation in time voltage feeding the stator windings. This ensures a smooth start right rotor of the electric submersible pump. Results. A block diagram of the intensity setter that is: with control unit, two units that form the exponential voltage supply emitter follower and regulatory elements. The mathematical expressions for voltage at the stator windings of the motor, changing exponentially, opening the angle of thyristor power unit thyristor the voltage regulator, which is determined through the initial angle of opening. Provided formula for pick-up voltage and minimum voltage, time constants, which are determined from the basic equations of motion and mechanical characteristics of the electric motor. Analytical investigated by the voltage dependence violation by changing the time constant flowing and growing exhibitor supply voltage stator electric circuit deepening pump. Originality. Proposed in the initial time on the stator windings of the electric pick-up voltage is applied. Under the influence of this voltage, motor rotor begins to accelerate. At the same time, pick-up voltage decreases the minimum startup voltage varies exponentially in which the rotor of the electric motor continues to rotate more steadily. Now the voltage at the motor stator windings increases exponentially to the nominal voltage of the supply network. This start flowing smoothly for the right time to establish nominal rotor speed of the motor. Practical value. Developed dial allows you to increase the intensity of the electric motor acceleration time and reduce the dynamic loads of the electric submersible pump.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2016
url http://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06
work_keys_str_mv AT lobovvi intensitysetterforadeviceofsmoothstartofsubmersiblepumpelectricmotor
AT lobovakv intensitysetterforadeviceofsmoothstartofsubmersiblepumpelectricmotor
AT lobovvi zadatčikintensivnostidlâustrojstvaplavnogopuskaélektrodvigatelâpogružnogonasosa
AT lobovakv zadatčikintensivnostidlâustrojstvaplavnogopuskaélektrodvigatelâpogružnogonasosa
AT lobovvi zadatčikíntensivnostídlâpristroûplavnogopuskuelektrodvigunazaglibnogonasosa
AT lobovakv zadatčikíntensivnostídlâpristroûplavnogopuskuelektrodvigunazaglibnogonasosa
first_indexed 2024-06-01T14:38:31Z
last_indexed 2024-06-01T14:38:31Z
_version_ 1800669979140423680
spelling eiekhpieduua-article-720182017-08-21T18:29:44Z INTENSITY SETTER FOR A DEVICE OF SMOOTH START OF SUBMERSIBLE PUMP ELECTRIC MOTOR ЗАДАТЧИК ИНТЕНСИВНОСТИ ДЛЯ УСТРОЙСТВА ПЛАВНОГО ПУСКА ЭЛЕКТРОДВИГАТЕЛЯ ПОГРУЖНОГО НАСОСА ЗАДАТЧИК ІНТЕНСИВНОСТІ ДЛЯ ПРИСТРОЮ ПЛАВНОГО ПУСКУ ЕЛЕКТРОДВИГУНА ЗАГЛИБНОГО НАСОСА Lobov, V. I. Lobova, K. V. submersible pump induction motor thyristor voltage regulator opening angle of thyristor intensity setter start-up acceleration time [62-83 621.313.333]-57-592 погружной насос асинхронный электродвигатель тиристорный регулятор напряжения угол открывания тиристоров задатчик интенсивности пуск время ускорения [62-83 621.313.333]-57-592 заглибний насос асинхронний електродвигун тиристорний регулятор напруги кут відкривання тиристорів задатчик інтенсивності пуск час прискорення [62-83 621.313.333]-57-592 Purpose. Development of an intensity setter, which in a rational law changes the opening thyristor the voltage regulator and effectively to changing power supply voltage stator windings of the electric pump deepening, ensuring a smooth start in a wide range. Methodology. Electric submersible pump belongs to the small inertia electric, since it is not significant total moment of inertia, not exceeding two moments of inertia of the motor and static moment on the shaft does not exceed forty percent of the nominal torque. For technical requirements that electric acceleration time should have no less than twenty seconds or more. Office starting modes of electric submersible pumps economically justified using thyristor voltage regulator by forming the dial changes the intensity of the necessary legislation in time voltage feeding the stator windings. This ensures a smooth start right rotor of the electric submersible pump. Results. A block diagram of the intensity setter that is: with control unit, two units that form the exponential voltage supply emitter follower and regulatory elements. The mathematical expressions for voltage at the stator windings of the motor, changing exponentially, opening the angle of thyristor power unit thyristor the voltage regulator, which is determined through the initial angle of opening. Provided formula for pick-up voltage and minimum voltage, time constants, which are determined from the basic equations of motion and mechanical characteristics of the electric motor. Analytical investigated by the voltage dependence violation by changing the time constant flowing and growing exhibitor supply voltage stator electric circuit deepening pump. Originality. Proposed in the initial time on the stator windings of the electric pick-up voltage is applied. Under the influence of this voltage, motor rotor begins to accelerate. At the same time, pick-up voltage decreases the minimum startup voltage varies exponentially in which the rotor of the electric motor continues to rotate more steadily. Now the voltage at the motor stator windings increases exponentially to the nominal voltage of the supply network. This start flowing smoothly for the right time to establish nominal rotor speed of the motor. Practical value. Developed dial allows you to increase the intensity of the electric motor acceleration time and reduce the dynamic loads of the electric submersible pump. Рассматривается задача построения задатчика интенсивности для формирования изменения угла открывания тиристоров регулятора напряжения. Это позволяет менять по сложной траектории напряжение питания на статоре электродвигателя погружного насоса, обеспечивая, тем самым, нужное время плавного ускорения вращения ротора. Для реализации задатчика интенсивности аппаратными средствами автоматизации представлена блок-схема, а программным путем – математические выражения. Розглядається задача побудови задатчика інтенсивності для формування зміни кута відкривання тиристорів регулятора напруги. Це дозволяє змінювати по складній траєкторії напругу живлення на статорі електродвигуна заглибного насосу, забезпечуючи цим потрібний час плавного прискорення обертання ротора. Для реалізації задатчика інтенсивності апаратними засобами автоматизації надано блок-схему, а програмним шляхом – математичні вирази. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016-06-25 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06 10.20998/2074-272X.2016.3.06 Electrical Engineering & Electromechanics; No. 3 (2016); 36-39 Электротехника и Электромеханика; № 3 (2016); 36-39 Електротехніка і Електромеханіка; № 3 (2016); 36-39 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06/67621 http://eie.khpi.edu.ua/article/view/2074-272X.2016.3.06/67622 Copyright (c) 2016 V. I. Lobov, K. V. Lobova https://creativecommons.org/licenses/by-nc/4.0