INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION

In this paper the authors calculate the losses in insulation system cable with XLPE-polyethylene as a solid dielectric insulation and with semiconductor polyethylene used as a conductor screen and an insulation screen. The paper is devoted to the investigation of losses in the insulation system of h...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автори: Shchebeniuk, L. A., Antonets, T. Yu.
Формат: Стаття
Мова:English
Ukrainian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2016.4.08
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-76393
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
Ukrainian
topic power cable
XLPE-cable
insulation losses
insulation system
loss factor
621.315.2
силовой кабель
СПЭ-кабель
потери в изоляции
система изоляции
тангенс угла диэлектрических потерь
621.315.2
силовий кабель
СПЕ-кабель
втрати в ізоляції
система ізоляції
тангенс кута діелектричних втрат
621.315.2
spellingShingle power cable
XLPE-cable
insulation losses
insulation system
loss factor
621.315.2
силовой кабель
СПЭ-кабель
потери в изоляции
система изоляции
тангенс угла диэлектрических потерь
621.315.2
силовий кабель
СПЕ-кабель
втрати в ізоляції
система ізоляції
тангенс кута діелектричних втрат
621.315.2
Shchebeniuk, L. A.
Antonets, T. Yu.
INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
topic_facet power cable
XLPE-cable
insulation losses
insulation system
loss factor
621.315.2
силовой кабель
СПЭ-кабель
потери в изоляции
система изоляции
тангенс угла диэлектрических потерь
621.315.2
силовий кабель
СПЕ-кабель
втрати в ізоляції
система ізоляції
тангенс кута діелектричних втрат
621.315.2
format Article
author Shchebeniuk, L. A.
Antonets, T. Yu.
author_facet Shchebeniuk, L. A.
Antonets, T. Yu.
author_sort Shchebeniuk, L. A.
title INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
title_short INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
title_full INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
title_fullStr INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
title_full_unstemmed INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION
title_sort investigation of losses in insulation of high-voltage power cables with xlpe insulation
title_alt ДОСЛІДЖЕННЯ ВТРАТ В ІЗОЛЯЦІЇ ВИСОКОВОЛЬТНИХ СИЛОВИХ КАБЕЛІВ З ПОЛІМЕРНОЮ ІЗОЛЯЦІЄЮ
ДОСЛІДЖЕННЯ ВТРАТ В ІЗОЛЯЦІЇ ВИСОКОВОЛЬТНИХ СИЛОВИХ КАБЕЛІВ З ПОЛІМЕРНОЮ ІЗОЛЯЦІЄЮ
description In this paper the authors calculate the losses in insulation system cable with XLPE-polyethylene as a solid dielectric insulation and with semiconductor polyethylene used as a conductor screen and an insulation screen. The paper is devoted to the investigation of losses in the insulation system of high-voltage XLPE-cables. The line of XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. The dielectric losses are voltage depended and related to the insulation system materials being used. All current in this insulation system are complex quantities containing both real (Re(I)) and imaginary (Im(I)) parts. Values of the loss factor of the insulation system at power frequency tgd are given astgd = Re(I)/Im(I). It was proposed the quantities criterion of the loss factor of the insulation system to high voltage XLPE-cables. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2016
url http://eie.khpi.edu.ua/article/view/2074-272X.2016.4.08
work_keys_str_mv AT shchebeniukla investigationoflossesininsulationofhighvoltagepowercableswithxlpeinsulation
AT antonetstyu investigationoflossesininsulationofhighvoltagepowercableswithxlpeinsulation
AT shchebeniukla doslídžennâvtratvízolâcíívisokovolʹtnihsilovihkabelívzpolímernoûízolâcíêû
AT antonetstyu doslídžennâvtratvízolâcíívisokovolʹtnihsilovihkabelívzpolímernoûízolâcíêû
first_indexed 2024-06-01T14:38:35Z
last_indexed 2024-06-01T14:38:35Z
_version_ 1800669983051612160
spelling eiekhpieduua-article-763932017-08-21T18:30:17Z INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE POWER CABLES WITH XLPE INSULATION ДОСЛІДЖЕННЯ ВТРАТ В ІЗОЛЯЦІЇ ВИСОКОВОЛЬТНИХ СИЛОВИХ КАБЕЛІВ З ПОЛІМЕРНОЮ ІЗОЛЯЦІЄЮ ДОСЛІДЖЕННЯ ВТРАТ В ІЗОЛЯЦІЇ ВИСОКОВОЛЬТНИХ СИЛОВИХ КАБЕЛІВ З ПОЛІМЕРНОЮ ІЗОЛЯЦІЄЮ Shchebeniuk, L. A. Antonets, T. Yu. power cable XLPE-cable insulation losses insulation system loss factor 621.315.2 силовой кабель СПЭ-кабель потери в изоляции система изоляции тангенс угла диэлектрических потерь 621.315.2 силовий кабель СПЕ-кабель втрати в ізоляції система ізоляції тангенс кута діелектричних втрат 621.315.2 In this paper the authors calculate the losses in insulation system cable with XLPE-polyethylene as a solid dielectric insulation and with semiconductor polyethylene used as a conductor screen and an insulation screen. The paper is devoted to the investigation of losses in the insulation system of high-voltage XLPE-cables. The line of XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. The dielectric losses are voltage depended and related to the insulation system materials being used. All current in this insulation system are complex quantities containing both real (Re(I)) and imaginary (Im(I)) parts. Values of the loss factor of the insulation system at power frequency tgd are given astgd = Re(I)/Im(I). It was proposed the quantities criterion of the loss factor of the insulation system to high voltage XLPE-cables. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function. Рассмотрен современный нормативный поход к определению потерь в изоляции силовых высоковольтных кабелей. В стационарном режиме нагрузки (100 % -ный коэффициент нагрузки) в соответствии с действующим международным стандартом (IEC 60287-1-1) диэлектрические потери зависят только от напряжения и от использованного изоляционного материала. Силовые высоковольтные кабели с изоляцией из сшитого полиэтилена (СПЭ-кабели) имеют безусловные преимущества перед традиционными, что обусловило их широкое использование во всех развитых странах и заметное сокращение использования других типов кабелей. Ряд существенных особенностей СПЭ-кабелей, которые влияют на температуру в элементах конструкции кабеля и, соответственно, на потери в них как в рабочих, так и в аварийных режимах эксплуатации, а именно: 1) большие, чем у традиционных маслом наполненных кабелей, значения площади сечения жил и толщины изоляции; 2) большая, чем у традиционных маслом наполненных кабелей, допустимая температура изоляции (90 °С); 3) большие, чем у традиционных маслом наполненных кабелей, значения толщины полупроводящих экранов по жиле и по изоляции; 4) существенная зависимость теплопроводности и теплоемкости полиэтиленовой изоляции от температуры;5) наличие элементов конструкции с высоким удельным тепловым сопротивлением (до 50 °С·м/Вт), что существенно влияет на температуру в элементах конструкции СПЭ-кабеля и, соответственно, на потери в них. Представлены данные о потерях в системе, состоящей из изоляции и полупроводящих экранов по жиле и по изоляции СПЭ-кабеля на напряжение 110 кВ для электрофизических и конструктивных характеристик материалов системы изоляции конкретного кабеля на основе схемы замещения. Ток в этой изоляционной системе является комплексной величиной, и значение тангенса угла ее диэлектрических потерь при промышленной частоте определено как отношение действительного тока к реактивному. В работе выполнен расчет потерь в системе изоляции, состоящей из изоляции из сшитого полиэтилена, экрана по жиле и экрана по изоляции из полупроводящего полиэтилена. Работа нацелена на разработку метода оценки пропускной способности СПЭ-кабелей в конкретных условиях испытаний и эксплуатации. Розглянуто сучасний нормативний підхід до визначення втрат в ізоляції силових високовольтних кабелів. В стаціонарному режимі навантаження (100 %-ий коефіцієнт навантаження) за діючим міжнародним стандартом (IEC60287-1-1) діелектричні втрати залежать тільки від напруги і від використаного ізоляційного матеріалу. Силові високовольтні кабелі з ізоляцією зі зшитого поліетилену (СПЕ-кабелі) мають безперечні переваги перед традиційними маслом наповненими, що зумовило їх повсюдне застосування у всіх розвинених країнах і помітне скорочення використання інших типів кабелю. Ряд суттєвих особливостей СПЕ-кабелів, які впливають на температуру в елементах конструкції кабелю і, відповідно, на втрати в цих елементах як робочому, так і в аварійному режимах в експлуатації, а саме: 1) більші, ніж у традиційних кабелів, значення площі перерізу жил і товщини ізоляції; 2) більша, ніж у традиційних маслом наповнених кабелів, допустима температура ізоляції (90 °С); 3) більші, ніж у традиційних кабелів, значення товщини ізоляції і напівпровідних екранів по жилі і по ізоляції; 4) суттєва залежність теплопровідності і теплоємності поліетиленової ізоляції від температури; 5) наявність елементів конструкції з високим питомим тепловим опором (до 50 °С·м/Вт), що суттєво змінює температуру в елементах конструкції кабелю і, відповідно втрати в цих елементах. Представлено дані щодо визначення втрат в системі ізоляції і напівпровідних екранів по жилі і по ізоляції СПЕ-кабелю на напругу 110 кВ для електрофізичних і конструктивних характеристик матеріалів системи ізоляції конкретного кабелю на основі схеми заміщення системи ізоляції. Струм в цій ізоляційній системі є комплексною величиною і значення тангенса кута її діелектричних втрат за промислової частоти визначено як відношення дійсного струму до реактивного. В роботі виконано розрахунок втрат в системі ізоляції, що складається з ізоляції із зшитого поліетилену, екранів по жилі і по ізоляції із напівпровідного поліетилену. Робота спрямована на створення методу визначення допустимого струму цих кабелів в конкретних умовах експлуатації. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016-08-30 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2016.4.08 10.20998/2074-272X.2016.4.08 Electrical Engineering & Electromechanics; No. 4 (2016); 58-62 Электротехника и Электромеханика; № 4 (2016); 58-62 Електротехніка і Електромеханіка; № 4 (2016); 58-62 2309-3404 2074-272X en uk http://eie.khpi.edu.ua/article/view/2074-272X.2016.4.08/72282 http://eie.khpi.edu.ua/article/view/2074-272X.2016.4.08/72283 Copyright (c) 2016 L. A. Shchebeniuk, T. Yu. Antonets https://creativecommons.org/licenses/by-nc/4.0