THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING

Purpose. Assessing the impact of load asymmetry of turbogenerator (TG) on the magnetic field distribution, on the electrical and energy processes in it based on the numerical-field analysis within the constraints regulated by the standards. Methodology. The calculation model of TG has been construct...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автор: Milykh, V. I.
Формат: Стаття
Мова:English
Russian
Опубліковано: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016
Теми:
Онлайн доступ:http://eie.khpi.edu.ua/article/view/2074-272X.2016.5.02
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Electrical Engineering & Electromechanics

Репозитарії

Electrical Engineering & Electromechanics
id eiekhpieduua-article-81019
record_format ojs
institution Electrical Engineering & Electromechanics
collection OJS
language English
Russian
topic turbo-generator
unbalanced loading
magnetic fields
numerical calculations
electromagnetic processes
temporal functions
621.313
турбогенератор
несимметричная нагрузка
магнитные поля
численные расчеты
электромагнитные процессы
временные функции
621.313
турбогенератор
несиметричне навантаження
магнітні поля
чисельні розрахунки
електромагнітні процеси
часові функції
621.313
spellingShingle turbo-generator
unbalanced loading
magnetic fields
numerical calculations
electromagnetic processes
temporal functions
621.313
турбогенератор
несимметричная нагрузка
магнитные поля
численные расчеты
электромагнитные процессы
временные функции
621.313
турбогенератор
несиметричне навантаження
магнітні поля
чисельні розрахунки
електромагнітні процеси
часові функції
621.313
Milykh, V. I.
THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
topic_facet turbo-generator
unbalanced loading
magnetic fields
numerical calculations
electromagnetic processes
temporal functions
621.313
турбогенератор
несимметричная нагрузка
магнитные поля
численные расчеты
электромагнитные процессы
временные функции
621.313
турбогенератор
несиметричне навантаження
магнітні поля
чисельні розрахунки
електромагнітні процеси
часові функції
621.313
format Article
author Milykh, V. I.
author_facet Milykh, V. I.
author_sort Milykh, V. I.
title THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
title_short THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
title_full THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
title_fullStr THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
title_full_unstemmed THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING
title_sort numerical-field analysis of the magnetic field and the electrical quantities in the turbogenerator stator under autonomous unbalanced loading
title_alt ЧИСЛЕННО-ПОЛЕВОЙ АНАЛИЗ МАГНИТНОГО ПОЛЯ И ЭЛЕКТРИЧЕСКИХ ВЕЛИЧИН В СТАТОРЕ ТУРБОГЕНЕРАТОРА ПРИ АВТОНОМНОЙ НЕСИММЕТРИЧНОЙ НАГРУЗКЕ
ЧИСЛЕННО-ПОЛЕВОЙ АНАЛИЗ МАГНИТНОГО ПОЛЯ И ЭЛЕКТРИЧЕСКИХ ВЕЛИЧИН В СТАТОРЕ ТУРБОГЕНЕРАТОРА ПРИ АВТОНОМНОЙ НЕСИММЕТРИЧНОЙ НАГРУЗКЕ
description Purpose. Assessing the impact of load asymmetry of turbogenerator (TG) on the magnetic field distribution, on the electrical and energy processes in it based on the numerical-field analysis within the constraints regulated by the standards. Methodology. The calculation model of TG has been constructed on the method of symmetrical components of the three-phase current system. The formed asymmetric system of the currents is used for multi-position numerical calculations of rotating magnetic fields. The temporal functions of the electromagnetic quantities which are subjected to the harmonic analysis are obtained on this basis. Results. Test calculations are conducted on a three-phase 35 MW TG during his work under autonomous unbalanced loading. The analysis of the temporal functions of the magnetic induction at different points of the TG stator and also similar functions of the magnetic flux linkage, EMF phase stator windings and other variables have been executed. Originality. Problems of exploitation of turbo-generators under unbalanced loading are detected by the consideration of their electromagnetic system on the whole, but not their simplified local parts, as usual. It has been shown that the temporal functions of EMF of the phase stator windings under unbalanced loading significantly differ in shape from sine waves and from each other and contain a number of significant upper harmonics. It has been detected that the phase currents would contain not only the first but also significant upper harmonics under unbalanced loading. Practical value. Analysis of the work of TG under unbalanced loading showed the «top» level of problems of electromagnetic character. It has been established that the function of the magnetic induction at the fixed points of the magnetic system on the whole have been changed but not in principle. The temporal functions of EMF, and, hence, the voltage of the stator phase windings significantly differ in shape from sine waves and from each other, there is a considerable imbalance of active powers generated by the individual phase windings of the stator. The information provided will allow the measures to ensure a durable and reliable operation of turbo-generators.
publisher National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine”
publishDate 2016
url http://eie.khpi.edu.ua/article/view/2074-272X.2016.5.02
work_keys_str_mv AT milykhvi thenumericalfieldanalysisofthemagneticfieldandtheelectricalquantitiesintheturbogeneratorstatorunderautonomousunbalancedloading
AT milykhvi čislennopolevojanalizmagnitnogopolâiélektričeskihveličinvstatoreturbogeneratorapriavtonomnojnesimmetričnojnagruzke
AT milykhvi numericalfieldanalysisofthemagneticfieldandtheelectricalquantitiesintheturbogeneratorstatorunderautonomousunbalancedloading
first_indexed 2024-06-01T14:38:36Z
last_indexed 2024-06-01T14:38:36Z
_version_ 1800669984278446080
spelling eiekhpieduua-article-810192017-08-21T18:31:00Z THE NUMERICAL-FIELD ANALYSIS OF THE MAGNETIC FIELD AND THE ELECTRICAL QUANTITIES IN THE TURBOGENERATOR STATOR UNDER AUTONOMOUS UNBALANCED LOADING ЧИСЛЕННО-ПОЛЕВОЙ АНАЛИЗ МАГНИТНОГО ПОЛЯ И ЭЛЕКТРИЧЕСКИХ ВЕЛИЧИН В СТАТОРЕ ТУРБОГЕНЕРАТОРА ПРИ АВТОНОМНОЙ НЕСИММЕТРИЧНОЙ НАГРУЗКЕ ЧИСЛЕННО-ПОЛЕВОЙ АНАЛИЗ МАГНИТНОГО ПОЛЯ И ЭЛЕКТРИЧЕСКИХ ВЕЛИЧИН В СТАТОРЕ ТУРБОГЕНЕРАТОРА ПРИ АВТОНОМНОЙ НЕСИММЕТРИЧНОЙ НАГРУЗКЕ Milykh, V. I. turbo-generator unbalanced loading magnetic fields numerical calculations electromagnetic processes temporal functions 621.313 турбогенератор несимметричная нагрузка магнитные поля численные расчеты электромагнитные процессы временные функции 621.313 турбогенератор несиметричне навантаження магнітні поля чисельні розрахунки електромагнітні процеси часові функції 621.313 Purpose. Assessing the impact of load asymmetry of turbogenerator (TG) on the magnetic field distribution, on the electrical and energy processes in it based on the numerical-field analysis within the constraints regulated by the standards. Methodology. The calculation model of TG has been constructed on the method of symmetrical components of the three-phase current system. The formed asymmetric system of the currents is used for multi-position numerical calculations of rotating magnetic fields. The temporal functions of the electromagnetic quantities which are subjected to the harmonic analysis are obtained on this basis. Results. Test calculations are conducted on a three-phase 35 MW TG during his work under autonomous unbalanced loading. The analysis of the temporal functions of the magnetic induction at different points of the TG stator and also similar functions of the magnetic flux linkage, EMF phase stator windings and other variables have been executed. Originality. Problems of exploitation of turbo-generators under unbalanced loading are detected by the consideration of their electromagnetic system on the whole, but not their simplified local parts, as usual. It has been shown that the temporal functions of EMF of the phase stator windings under unbalanced loading significantly differ in shape from sine waves and from each other and contain a number of significant upper harmonics. It has been detected that the phase currents would contain not only the first but also significant upper harmonics under unbalanced loading. Practical value. Analysis of the work of TG under unbalanced loading showed the «top» level of problems of electromagnetic character. It has been established that the function of the magnetic induction at the fixed points of the magnetic system on the whole have been changed but not in principle. The temporal functions of EMF, and, hence, the voltage of the stator phase windings significantly differ in shape from sine waves and from each other, there is a considerable imbalance of active powers generated by the individual phase windings of the stator. The information provided will allow the measures to ensure a durable and reliable operation of turbo-generators. На основе численных расчетов вращающегося магнитного поля проведена оценка работы турбогенератора при несимметричной нагрузке. Анализируются временные функции магнитной индукции в неподвижных точках магнитной системы статора, форма и гармонический состав ЭДС его обмоток, их мощности. Результаты расчетов при несимметричной нагрузке сопоставляются с аналогичными результатами при симметричной нагрузке. На основі чисельних розрахунків обертового магнітного поля виконана оцінка роботи турбогенератора при несиметричному навантаженні. Аналізуються часові функції магнітної індукції в нерухомих точках магнітної системи статора, форма і гармонійний склад ЕРС його обмоток, їхні потужності. Результати розрахунків при несиметричному навантаженні порівнюються з аналогічними результатами при симетричному навантаженні. National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2016-10-31 Article Article application/pdf application/pdf http://eie.khpi.edu.ua/article/view/2074-272X.2016.5.02 10.20998/2074-272X.2016.5.02 Electrical Engineering & Electromechanics; No. 5 (2016); 16-22 Электротехника и Электромеханика; № 5 (2016); 16-22 Електротехніка і Електромеханіка; № 5 (2016); 16-22 2309-3404 2074-272X en ru http://eie.khpi.edu.ua/article/view/2074-272X.2016.5.02/77271 http://eie.khpi.edu.ua/article/view/2074-272X.2016.5.02/77272 Copyright (c) 2016 V. I. Milykh https://creativecommons.org/licenses/by-nc/4.0