Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills
As a result of the damage to the structures of the supporting front and the destruction of the protective screens on the reclamation systems, tailings storage facilities, and landfills due to military operations, processes of flooding and pollution of water resources are taking place on the territor...
Збережено в:
Дата: | 2023 |
---|---|
Автори: | , |
Формат: | Стаття |
Мова: | Ukrainian |
Опубліковано: |
Kyiv National University of Construction and Architecture
2023
|
Теми: | |
Онлайн доступ: | https://es-journal.in.ua/article/view/297265 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Environmental safety and natural resources |
Репозитарії
Environmental safety and natural resourcesid |
es-journalinua-article-297265 |
---|---|
record_format |
ojs |
institution |
Environmental safety and natural resources |
collection |
OJS |
language |
Ukrainian |
topic |
influence of military operations pollution of water resources aquifer screens of reclamation facilities filtration losses вплив воєнних дій забруднення водних ресурсів водоносний горизонт екрани меліоративних споруд фільтраційні втрати |
spellingShingle |
influence of military operations pollution of water resources aquifer screens of reclamation facilities filtration losses вплив воєнних дій забруднення водних ресурсів водоносний горизонт екрани меліоративних споруд фільтраційні втрати Маршалл, Д.І. Шевчук, Я.В. Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
topic_facet |
influence of military operations pollution of water resources aquifer screens of reclamation facilities filtration losses вплив воєнних дій забруднення водних ресурсів водоносний горизонт екрани меліоративних споруд фільтраційні втрати |
format |
Article |
author |
Маршалл, Д.І. Шевчук, Я.В. |
author_facet |
Маршалл, Д.І. Шевчук, Я.В. |
author_sort |
Маршалл, Д.І. |
title |
Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_short |
Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_full |
Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_fullStr |
Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_full_unstemmed |
Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_sort |
assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills |
title_alt |
Оцінка визначення параметрів забруднення підземних вод із зруйнованих меліоративних споруд, хвостосховищ та затоплених сміттєзвалищ |
description |
As a result of the damage to the structures of the supporting front and the destruction of the protective screens on the reclamation systems, tailings storage facilities, and landfills due to military operations, processes of flooding and pollution of water resources are taking place on the territory of Ukraine. This issue requires an assessment and forecast of the further development of events at the damaged buildings. An integral component of such an assessment is the methodology of approaches to the filtration calculations of the consumption of polluted water through a closed protective screen using the analysis of migration due to the aquifer. In this work, the issues of the theoretical approach to the determination of head loss and filtration through a protective screen for the assessment and further forecast of groundwater pollution by filtration flow from tailings, landfills, and reclamation canals due to their flooding due to military actions are considered. Approaches to the determination of pressure loss through a shielded structure in the event of various types of damage and at various stages of water filtration from channels are given. According to the proposed formulas, the loss of water from the main channel of the Ingulets irrigation system and the filtration coefficient of the damaged lining due to the destruction of the dam of the Kakhovskaya Hydro Electric Station were determined. The results of the research will be useful in making management decisions regarding the protection of water bodies from pollution and in the restoration of damaged structures. |
publisher |
Kyiv National University of Construction and Architecture |
publishDate |
2023 |
url |
https://es-journal.in.ua/article/view/297265 |
work_keys_str_mv |
AT maršalldí assessmentofthedeterminationofgroundwaterpollutionparametersfromdestroyedameliorativestructurestailstorageandfloodedlandfills AT ševčukâv assessmentofthedeterminationofgroundwaterpollutionparametersfromdestroyedameliorativestructurestailstorageandfloodedlandfills AT maršalldí ocínkaviznačennâparametrívzabrudnennâpídzemnihvodízzrujnovanihmelíorativnihsporudhvostoshoviŝtazatoplenihsmíttêzvaliŝ AT ševčukâv ocínkaviznačennâparametrívzabrudnennâpídzemnihvodízzrujnovanihmelíorativnihsporudhvostoshoviŝtazatoplenihsmíttêzvaliŝ |
first_indexed |
2024-04-21T19:47:00Z |
last_indexed |
2024-04-21T19:47:00Z |
_version_ |
1796974912368279552 |
spelling |
es-journalinua-article-2972652024-01-23T10:00:35Z Assessment of the determination of groundwater pollution parameters from destroyed ameliorative structures, tail storage and flooded landfills Оцінка визначення параметрів забруднення підземних вод із зруйнованих меліоративних споруд, хвостосховищ та затоплених сміттєзвалищ Маршалл, Д.І. Шевчук, Я.В. influence of military operations pollution of water resources aquifer screens of reclamation facilities filtration losses вплив воєнних дій забруднення водних ресурсів водоносний горизонт екрани меліоративних споруд фільтраційні втрати As a result of the damage to the structures of the supporting front and the destruction of the protective screens on the reclamation systems, tailings storage facilities, and landfills due to military operations, processes of flooding and pollution of water resources are taking place on the territory of Ukraine. This issue requires an assessment and forecast of the further development of events at the damaged buildings. An integral component of such an assessment is the methodology of approaches to the filtration calculations of the consumption of polluted water through a closed protective screen using the analysis of migration due to the aquifer. In this work, the issues of the theoretical approach to the determination of head loss and filtration through a protective screen for the assessment and further forecast of groundwater pollution by filtration flow from tailings, landfills, and reclamation canals due to their flooding due to military actions are considered. Approaches to the determination of pressure loss through a shielded structure in the event of various types of damage and at various stages of water filtration from channels are given. According to the proposed formulas, the loss of water from the main channel of the Ingulets irrigation system and the filtration coefficient of the damaged lining due to the destruction of the dam of the Kakhovskaya Hydro Electric Station were determined. The results of the research will be useful in making management decisions regarding the protection of water bodies from pollution and in the restoration of damaged structures. Внаслідок пошкоджень споруд підпорного фронту та руйнувань захисних екранів на меліоративних системах, хвостосховищах, сміттєзвалищ через воєнні дії на території України відбуваються процеси підтоплення та забруднення водних ресурсів. Дане питання потребує оцінки та прогнозу подальшого розвитку подій на пошкоджених спорудах. Невід’ємною складовою такої оцінки є методологія підходів до фільтраційних розрахунків витрат забрудненої води через пошкоджений захисний екран з метою аналізу міграції забруднень водоносним горизонтом. В даній роботі розглянуті питання теоретичного підходу щодо визначення втрат напору та фільтрації через захисний екран для оцінки і подальшого прогнозу забруднення підземних вод фільтраційним потоком з хвостосховищ, сміттєзвалищ, меліоративних каналів внаслідок їх затоплення через воєнні дії. Наведені підходи до визначення втрат напору через екрановану споруду при різного роду пошкодженнях і на різних стадіях фільтрації води з каналів. Визначено втрати води з магістрального каналу Інгулецької зрошувальної системи і коефіцієнт фільтрації пошкодженого облицювання за запропонованими формулами внаслідок руйнування дамби Каховської ГЕС. Результати досліджень стануть в нагоді при прийнятті управлінських рішень щодо захисту водних об’єктів від забруднення та при відновленні пошкоджених споруд. Kyiv National University of Construction and Architecture 2023-12-26 Article Article application/pdf https://es-journal.in.ua/article/view/297265 10.32347/2411-4049.2023.4.21-31 Environmental safety and natural resources; Vol. 48 No. 4 (2023): Environmental safety and natural resources; 21-31 Екологічна безпека та природокористування; Том 48 № 4 (2023): Екологічна безпека та природокористування; 21-31 2616-2121 2411-4049 10.32347/2411-4049.2023.4 uk https://es-journal.in.ua/article/view/297265/290202 Авторське право (c) 2023 Marshall D.I., Shevchuk Ya.V. http://creativecommons.org/licenses/by/4.0 |