At Budker INP SB RAS, a prototype of high-power industrial electron accelerator for the energy of 5 MeV, named ILU-12, has been successfully commissioned. The accelerator operates at 176 MHz. The paper presents the accelerator concept together with simulation results for the accelerating structure...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2008
Автори: Auslender, V.L., Bryazgin, A.A., Chernov, K.N., Cheskidov, V.G., Factorovich, B.L., Gorbunov, V.A., Gornakov, I.V., Korobejnikov, M.V., Kuznetsov, G.I., Makarov, I.G., Matyash, N.V., Ostreiko, G.N., Panfilov, A.D., Serdobintsev, G.V., Tarnetsky, V.V., Tiunov, M.A., Tkachenko, V.O., Tuvik, A.A.
Формат: Стаття
Мова:English
Опубліковано: ІЯФ СО РАН Росії 2008
Назва видання:Вопросы атомной науки и техники
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/111201
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:ILU-12 commissioning / V.L. Auslender, A.A. Bryazgin, K.N. Chernov, V.G. Cheskidov, B.L. Factorovich, V.A. Gorbunov, I.V. Gornakov, M.V. Korobejnikov, G.I. Kuznetsov, A.N. Lukin, I.G. Makarov, N.V. Matyash, G.N. Ostreiko, A.D. Panfilov, G.V. Serdobintsev, V.V. Tarnetsky, M.A. Tiunov, V.O. Tkachenko, A.A. Tuvik // Вопросы атомной науки и техники. — 2008. — № 3. — С. 20-24. — Бібліогр.: 9 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Опис
Резюме:At Budker INP SB RAS, a prototype of high-power industrial electron accelerator for the energy of 5 MeV, named ILU-12, has been successfully commissioned. The accelerator operates at 176 MHz. The paper presents the accelerator concept together with simulation results for the accelerating structure, beam injection and dynamics. The obtained beam pulsed power of 1,5 MW at the structure electron efficiency of 67% is close to the simulation value. Improvements of beam transportation and energy spectrum due to the injection regime optimization were experimentally proven. The results obtained are discussed.