Investigation of x-ray emission from high-current discharges of the PF type
The invited paper reports on measurements of soft x-rays emitted from hot plasmas produced in a modernised PF-1000U facility. The discharges were performed at the D2-filling with or without a Ne-admixture, under the initial pressure of 0.9 or 1.5 Torr and at the initial charging voltage equal to...
Збережено в:
Дата: | 2016 |
---|---|
Автори: | , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2016
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/115330 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Investigation of x-ray emission from high-current discharges of the PF type / E. Skladnik-Sadowska, M.J. Sadowski, K. Malinowski, W. Surala, D. Zaloga, M. Paduch, E. Zielinska, K. Tomaszewski // Вопросы атомной науки и техники. — 2016. — № 6. — С. 112-116. — Бібліогр.: 19 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of UkraineРезюме: | The invited paper reports on measurements of soft x-rays emitted from hot plasmas produced in a modernised
PF-1000U facility. The discharges were performed at the D2-filling with or without a Ne-admixture, under the initial
pressure of 0.9 or 1.5 Torr and at the initial charging voltage equal to 16 or 18 kV. Time-integrated x-ray images
were recorded with a pinhole camera situated side-on, at an angle of 75º to the z-axis. Differences in the pinch
column structure were observed. Time-resolved measurements were performed with four PIN diodes located behind
filtered pinholes. Two couples of PIN diodes (with Be-filters of 7 and 10 μm in thickness) observed 30 mm-diam.
regions which had centres at a distance of 30 and 60 mm form the electrode outlets. From the recorded timeresolved
x-ray signals the electron temperatures (Te) were calculated. For the pure D2-discharges the estimated Te
values ranged from 75 to 250 eV depending on the discharge conditions. For discharges with a Ne-admixture Te values were higher and reached about 800 eV. |
---|