A new control unit for probing ion beam forming in HIBP diagnostic systems
This paper describes the new version of electronic control unit for ion beam forming in the Heavy Ion Beam Probing (HIBP) diagnostics. This improved unit was developed, manufactured, installed and tested on HIBP system for Uragan-2M torsatron. Some new schematic solutions that are implemented in t...
Збережено в:
Дата: | 2016 |
---|---|
Автори: | , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2016
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/115470 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | A new control unit for probing ion beam forming in HIBP diagnostic systems / A.I. Zhezhera, A.A. Chmyga, G.N. Deshko, A.S. Kozachek, A.D. Komarov, L.I. Krupnik, S.M. Khrebtov // Вопросы атомной науки и техники. — 2016. — № 6. — С. 310-313. — Бібліогр.: 2 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of UkraineРезюме: | This paper describes the new version of electronic control unit for ion beam forming in the Heavy Ion Beam
Probing (HIBP) diagnostics. This improved unit was developed, manufactured, installed and tested on HIBP system
for Uragan-2M torsatron. Some new schematic solutions that are implemented in this unit were created as the result
of long-term work with various types of injector power supplies and their control systems, installed on HIBP
diagnostics for different fusion devices. The new advanced and highly efficient electronic control block has been
constructed. It provides all the necessary functions for adjusting the parameters of the ion beam as well as handy and
stable operation of the injector in the experiments on Uragan-2M torsatron. |
---|