Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease

The influence of the sensitive element fabrication technology and noise performance of surface plasmon resonance (SPR) immunosensor on sensitivity and stability of operation inherent to the “Plasmon” series instrument has been investigated to improve reliability of diagnosis and treatment of the Eps...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автор: Khrystosenko, R.V.
Формат: Стаття
Мова:English
Опубліковано: Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України 2016
Назва видання:Semiconductor Physics Quantum Electronics & Optoelectronics
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/121531
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease / R.V. Khrystosenko // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2016. — Т. 19, № 1. — С. 84-89. — Бібліогр.: 19 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-121531
record_format dspace
spelling irk-123456789-1215312017-06-15T03:05:21Z Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease Khrystosenko, R.V. The influence of the sensitive element fabrication technology and noise performance of surface plasmon resonance (SPR) immunosensor on sensitivity and stability of operation inherent to the “Plasmon” series instrument has been investigated to improve reliability of diagnosis and treatment of the Epstein–Barr herpes virus disease. To minimize the effect of the temperature change induced noise, compensation (introduction of the reference channel) and stabilization (active thermal control) methods were applied, allowing to substantially enhance resolution of the used SPR sensor system. 2016 Article Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease / R.V. Khrystosenko // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2016. — Т. 19, № 1. — С. 84-89. — Бібліогр.: 19 назв. — англ. 1560-8034 DOI: 10.15407/spqeo19.01.084 PACS 73.20.Mf, 87.55.fk http://dspace.nbuv.gov.ua/handle/123456789/121531 en Semiconductor Physics Quantum Electronics & Optoelectronics Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
description The influence of the sensitive element fabrication technology and noise performance of surface plasmon resonance (SPR) immunosensor on sensitivity and stability of operation inherent to the “Plasmon” series instrument has been investigated to improve reliability of diagnosis and treatment of the Epstein–Barr herpes virus disease. To minimize the effect of the temperature change induced noise, compensation (introduction of the reference channel) and stabilization (active thermal control) methods were applied, allowing to substantially enhance resolution of the used SPR sensor system.
format Article
author Khrystosenko, R.V.
spellingShingle Khrystosenko, R.V.
Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
Semiconductor Physics Quantum Electronics & Optoelectronics
author_facet Khrystosenko, R.V.
author_sort Khrystosenko, R.V.
title Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
title_short Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
title_full Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
title_fullStr Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
title_full_unstemmed Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease
title_sort optimization of surface plasmon resonance based biosensor for clinical diagnosis of the epstein–barr herpes virus disease
publisher Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України
publishDate 2016
url http://dspace.nbuv.gov.ua/handle/123456789/121531
citation_txt Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease / R.V. Khrystosenko // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2016. — Т. 19, № 1. — С. 84-89. — Бібліогр.: 19 назв. — англ.
series Semiconductor Physics Quantum Electronics & Optoelectronics
work_keys_str_mv AT khrystosenkorv optimizationofsurfaceplasmonresonancebasedbiosensorforclinicaldiagnosisoftheepsteinbarrherpesvirusdisease
first_indexed 2023-10-18T20:39:47Z
last_indexed 2023-10-18T20:39:47Z
_version_ 1796150786612264960