Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base

The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has b...

Full description

Saved in:
Bibliographic Details
Main Authors: Viday, Yu.T., Tarasov, V.A., Gorbacheva, T.E.
Format: Article
Language:English
Published: НТК «Інститут монокристалів» НАН України 2008
Series:Functional Materials
Subjects:
Online Access:http://dspace.nbuv.gov.ua/handle/123456789/134538
Tags: Add Tag
No Tags, Be the first to tag this record!
id irk-123456789-134538
record_format dspace
spelling irk-123456789-1345382018-06-14T03:07:36Z Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base Viday, Yu.T. Tarasov, V.A. Gorbacheva, T.E. Technology The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has been shown to result in an increased background counting rate, decreased detector sensitivity and resolution. These changes in radiometric parameters are influenced significantly by the state of the radiation input surfaces of the Csl(TI) and p-terphenyl detectors. Розглянуто вплив непропорційності світлового виходу та енергії випромінювання при реєстрації низькопроникного випромінювання на радіометричні характеристики детекторів на основі йодіду цезія, активованого талієм, та на основі п-терфенілу. Показано, що збільшення непропорціональності світлового виходу та енергії при реєстрації а-частинок з енергіями 5 МеВ і 2 МеВ приводить до збільшення фонової швидкості рахування, зменшення чутливості детектора та його роздільної здатності. На ці зміни радіометричних параметрів суттєвий вплив чинить стан вхідної для випромінювання поверхні сцинтиляторів СsІ(ТІ) та п-терфенілу. Рассмотрено влияние непропорциональности светового выхода и энергии излучения при регистрации малопроникающего излучения на радиометрические характеристики детекторов йодистого цезия, активированного таллием, или на основе п-терфенила. Показано, что увеличение непропорциональности светового выхода и энергии при регистрации а-частиц с энергиями 5 МэВ и 2 МэВ приводит к увеличению фоновой скорости счета, уменьшению чувствительности детектора и его разделяющей способности. На эти изменения радиометрических параметров существенное влияние оказывает состояние входной для излучения поверхности сцинтилляторов Csl(ТJ) и п-терфенила. 2008 Article Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base // Yu.T. Viday, V.A. Tarasov, T.E. Gorbacheva // Functional Materials. — 2008. — Т. 15, № 2. — С. 279-282. — Бібліогр.: 5 назв. — англ. 1027-5495 http://dspace.nbuv.gov.ua/handle/123456789/134538 en Functional Materials НТК «Інститут монокристалів» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Technology
Technology
spellingShingle Technology
Technology
Viday, Yu.T.
Tarasov, V.A.
Gorbacheva, T.E.
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
Functional Materials
description The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has been shown to result in an increased background counting rate, decreased detector sensitivity and resolution. These changes in radiometric parameters are influenced significantly by the state of the radiation input surfaces of the Csl(TI) and p-terphenyl detectors.
format Article
author Viday, Yu.T.
Tarasov, V.A.
Gorbacheva, T.E.
author_facet Viday, Yu.T.
Tarasov, V.A.
Gorbacheva, T.E.
author_sort Viday, Yu.T.
title Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
title_short Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
title_full Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
title_fullStr Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
title_full_unstemmed Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
title_sort influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
publisher НТК «Інститут монокристалів» НАН України
publishDate 2008
topic_facet Technology
url http://dspace.nbuv.gov.ua/handle/123456789/134538
citation_txt Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base // Yu.T. Viday, V.A. Tarasov, T.E. Gorbacheva // Functional Materials. — 2008. — Т. 15, № 2. — С. 279-282. — Бібліогр.: 5 назв. — англ.
series Functional Materials
work_keys_str_mv AT vidayyut influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase
AT tarasovva influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase
AT gorbachevate influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase
first_indexed 2023-10-18T21:08:58Z
last_indexed 2023-10-18T21:08:58Z
_version_ 1796152060664610816