2025-02-21T08:18:42-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: Query fl=%2A&wt=json&json.nl=arrarr&q=id%3A%22irk-123456789-134538%22&qt=morelikethis&rows=5
2025-02-21T08:18:42-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: => GET http://localhost:8983/solr/biblio/select?fl=%2A&wt=json&json.nl=arrarr&q=id%3A%22irk-123456789-134538%22&qt=morelikethis&rows=5
2025-02-21T08:18:42-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: <= 200 OK
2025-02-21T08:18:42-05:00 DEBUG: Deserialized SOLR response
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base
The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has b...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
НТК «Інститут монокристалів» НАН України
2008
|
Series: | Functional Materials |
Subjects: | |
Online Access: | http://dspace.nbuv.gov.ua/handle/123456789/134538 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
irk-123456789-134538 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-1345382018-06-14T03:07:36Z Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base Viday, Yu.T. Tarasov, V.A. Gorbacheva, T.E. Technology The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has been shown to result in an increased background counting rate, decreased detector sensitivity and resolution. These changes in radiometric parameters are influenced significantly by the state of the radiation input surfaces of the Csl(TI) and p-terphenyl detectors. Розглянуто вплив непропорційності світлового виходу та енергії випромінювання при реєстрації низькопроникного випромінювання на радіометричні характеристики детекторів на основі йодіду цезія, активованого талієм, та на основі п-терфенілу. Показано, що збільшення непропорціональності світлового виходу та енергії при реєстрації а-частинок з енергіями 5 МеВ і 2 МеВ приводить до збільшення фонової швидкості рахування, зменшення чутливості детектора та його роздільної здатності. На ці зміни радіометричних параметрів суттєвий вплив чинить стан вхідної для випромінювання поверхні сцинтиляторів СsІ(ТІ) та п-терфенілу. Рассмотрено влияние непропорциональности светового выхода и энергии излучения при регистрации малопроникающего излучения на радиометрические характеристики детекторов йодистого цезия, активированного таллием, или на основе п-терфенила. Показано, что увеличение непропорциональности светового выхода и энергии при регистрации а-частиц с энергиями 5 МэВ и 2 МэВ приводит к увеличению фоновой скорости счета, уменьшению чувствительности детектора и его разделяющей способности. На эти изменения радиометрических параметров существенное влияние оказывает состояние входной для излучения поверхности сцинтилляторов Csl(ТJ) и п-терфенила. 2008 Article Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base // Yu.T. Viday, V.A. Tarasov, T.E. Gorbacheva // Functional Materials. — 2008. — Т. 15, № 2. — С. 279-282. — Бібліогр.: 5 назв. — англ. 1027-5495 http://dspace.nbuv.gov.ua/handle/123456789/134538 en Functional Materials НТК «Інститут монокристалів» НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
topic |
Technology Technology |
spellingShingle |
Technology Technology Viday, Yu.T. Tarasov, V.A. Gorbacheva, T.E. Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base Functional Materials |
description |
The effect of the non-proportionality in light yield and the radiation energy on the radiometric characteristics of thallium-doped cesium iodide detectors and p-terphenyl ones. The increase of the non-proportionality in the energy and light yield at the recording of 5 MeV and 2 MeV a-particles has been shown to result in an increased background counting rate, decreased detector sensitivity and resolution. These changes in radiometric parameters are influenced significantly by the state of the radiation input surfaces of the Csl(TI) and p-terphenyl detectors. |
format |
Article |
author |
Viday, Yu.T. Tarasov, V.A. Gorbacheva, T.E. |
author_facet |
Viday, Yu.T. Tarasov, V.A. Gorbacheva, T.E. |
author_sort |
Viday, Yu.T. |
title |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
title_short |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
title_full |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
title_fullStr |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
title_full_unstemmed |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
title_sort |
influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base |
publisher |
НТК «Інститут монокристалів» НАН України |
publishDate |
2008 |
topic_facet |
Technology |
url |
http://dspace.nbuv.gov.ua/handle/123456789/134538 |
citation_txt |
Influence of inorganic scintillator light output non-proportionality and energy of registered ionizing radiation on radiometric parameters of detectors on their base // Yu.T. Viday, V.A. Tarasov, T.E. Gorbacheva // Functional Materials. — 2008. — Т. 15, № 2. — С. 279-282. — Бібліогр.: 5 назв. — англ. |
series |
Functional Materials |
work_keys_str_mv |
AT vidayyut influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase AT tarasovva influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase AT gorbachevate influenceofinorganicscintillatorlightoutputnonproportionalityandenergyofregisteredionizingradiationonradiometricparametersofdetectorsontheirbase |
first_indexed |
2023-10-18T21:08:58Z |
last_indexed |
2023-10-18T21:08:58Z |
_version_ |
1796152060664610816 |