Large area detector of low-energy gamma radiation

Detectors for registration of low-energy gamma radiation based on plastic scintillator UPS-923A with composite YSO:Ce and CsI:Tl layers were developed. Size and concentrations of granules in the composite scintillators were determined experimentally. Additional composite layer in the detector design...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2017
Автори: Nepokupnaya, T.A., Ananenko, A.A., Boyarintsev, A.Yu., Bobovnikov, A.A., Gektin, A.V., Kovalchuk, S.N., Onufriyev, Yu.D., Pedash, V.Yu.
Формат: Стаття
Мова:English
Опубліковано: НТК «Інститут монокристалів» НАН України 2017
Назва видання:Functional Materials
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/136893
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Large area detector of low-energy gamma radiation / T.A. Nepokupnaya, A.A. Ananenko, A.Yu. Boyarintsev, A.A. Bobovnikov, A.V. Gektin, S.N. Kovalchuk, Yu.D. Onufriyev, V.Yu. Pedash // Functional Materials. — 2017. — Т. 24, № 4. — С. 678-681. — Бібліогр.: 6 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-136893
record_format dspace
spelling irk-123456789-1368932018-06-17T03:11:47Z Large area detector of low-energy gamma radiation Nepokupnaya, T.A. Ananenko, A.A. Boyarintsev, A.Yu. Bobovnikov, A.A. Gektin, A.V. Kovalchuk, S.N. Onufriyev, Yu.D. Pedash, V.Yu. Devices and instruments Detectors for registration of low-energy gamma radiation based on plastic scintillator UPS-923A with composite YSO:Ce and CsI:Tl layers were developed. Size and concentrations of granules in the composite scintillators were determined experimentally. Additional composite layer in the detector design allowed reducing the gamma radiation registration threshold down to 20 keV. It was shown that registration efficiency of 59.5 keV gamma-quanta (Am²⁴¹) of the detector with YSO:Ce composite layer was 4 times higher than that of UPS-923A. The detector with CsI:Tl composite layer had 1.5 times higher sensitivity and almost 2 times lower minimum detectable activity in comparison to UPS-923A under Am²⁴¹ irradiation. 2017 Article Large area detector of low-energy gamma radiation / T.A. Nepokupnaya, A.A. Ananenko, A.Yu. Boyarintsev, A.A. Bobovnikov, A.V. Gektin, S.N. Kovalchuk, Yu.D. Onufriyev, V.Yu. Pedash // Functional Materials. — 2017. — Т. 24, № 4. — С. 678-681. — Бібліогр.: 6 назв. — англ. 1027-5495 DOI: https://doi.org/10.15407/fm24.04.678 http://dspace.nbuv.gov.ua/handle/123456789/136893 en Functional Materials НТК «Інститут монокристалів» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Devices and instruments
Devices and instruments
spellingShingle Devices and instruments
Devices and instruments
Nepokupnaya, T.A.
Ananenko, A.A.
Boyarintsev, A.Yu.
Bobovnikov, A.A.
Gektin, A.V.
Kovalchuk, S.N.
Onufriyev, Yu.D.
Pedash, V.Yu.
Large area detector of low-energy gamma radiation
Functional Materials
description Detectors for registration of low-energy gamma radiation based on plastic scintillator UPS-923A with composite YSO:Ce and CsI:Tl layers were developed. Size and concentrations of granules in the composite scintillators were determined experimentally. Additional composite layer in the detector design allowed reducing the gamma radiation registration threshold down to 20 keV. It was shown that registration efficiency of 59.5 keV gamma-quanta (Am²⁴¹) of the detector with YSO:Ce composite layer was 4 times higher than that of UPS-923A. The detector with CsI:Tl composite layer had 1.5 times higher sensitivity and almost 2 times lower minimum detectable activity in comparison to UPS-923A under Am²⁴¹ irradiation.
format Article
author Nepokupnaya, T.A.
Ananenko, A.A.
Boyarintsev, A.Yu.
Bobovnikov, A.A.
Gektin, A.V.
Kovalchuk, S.N.
Onufriyev, Yu.D.
Pedash, V.Yu.
author_facet Nepokupnaya, T.A.
Ananenko, A.A.
Boyarintsev, A.Yu.
Bobovnikov, A.A.
Gektin, A.V.
Kovalchuk, S.N.
Onufriyev, Yu.D.
Pedash, V.Yu.
author_sort Nepokupnaya, T.A.
title Large area detector of low-energy gamma radiation
title_short Large area detector of low-energy gamma radiation
title_full Large area detector of low-energy gamma radiation
title_fullStr Large area detector of low-energy gamma radiation
title_full_unstemmed Large area detector of low-energy gamma radiation
title_sort large area detector of low-energy gamma radiation
publisher НТК «Інститут монокристалів» НАН України
publishDate 2017
topic_facet Devices and instruments
url http://dspace.nbuv.gov.ua/handle/123456789/136893
citation_txt Large area detector of low-energy gamma radiation / T.A. Nepokupnaya, A.A. Ananenko, A.Yu. Boyarintsev, A.A. Bobovnikov, A.V. Gektin, S.N. Kovalchuk, Yu.D. Onufriyev, V.Yu. Pedash // Functional Materials. — 2017. — Т. 24, № 4. — С. 678-681. — Бібліогр.: 6 назв. — англ.
series Functional Materials
work_keys_str_mv AT nepokupnayata largeareadetectoroflowenergygammaradiation
AT ananenkoaa largeareadetectoroflowenergygammaradiation
AT boyarintsevayu largeareadetectoroflowenergygammaradiation
AT bobovnikovaa largeareadetectoroflowenergygammaradiation
AT gektinav largeareadetectoroflowenergygammaradiation
AT kovalchuksn largeareadetectoroflowenergygammaradiation
AT onufriyevyud largeareadetectoroflowenergygammaradiation
AT pedashvyu largeareadetectoroflowenergygammaradiation
first_indexed 2023-10-18T21:14:56Z
last_indexed 2023-10-18T21:14:56Z
_version_ 1796152304205824000