Low-energy X-ray radiation after the biological shielding of electron accelerators

The bremsstrahlung of electrons from thick converters and its passage through concrete shielding of accelerators at different angles to the axis of the electron beam were calculated using GEANT4. Numerical estimates of the residual low-energy component of X-ray radiation after passing through the b...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2018
Автори: Bochek, G.L., Deiev, О.S., Dubina, V.N., Kiprich, S.K., Kapliy, O.A., Maslov, N.I., Ovchinnik, V.D., Potin, S.M., Shulika, M.Yu., Vasiliev, G.P., Yalovenko, V.I.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2018
Назва видання:Вопросы атомной науки и техники
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/147312
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Low-energy X-ray radiation after the biological shielding of electron accelerators / G.L. Bochek, О.S. Deiev, V.N. Dubina, S.K. Kiprich, O.A. Kapliy, N.I. Maslov, V.D. Ovchinnik, S.M. Potin, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Вопросы атомной науки и техники. — 2018. — № 3. — С. 172-177. — Бібліогр.: 16 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Опис
Резюме:The bremsstrahlung of electrons from thick converters and its passage through concrete shielding of accelerators at different angles to the axis of the electron beam were calculated using GEANT4. Numerical estimates of the residual low-energy component of X-ray radiation after passing through the biological protection were carried out at an electron energy of up to 300 MeV. Additional reasons for the possible appearance of soft X-ray radiation after the shielding are considered. Experimental measurements of the spectral and dosimetric characteristics were performed by a silicon uncooled detector with the energy resolution of ~ 1 keV and spectral sensitivity in the range 5...150 keV. The comparison of the estimated dose (using the number of counts in Si detector) with indications of dosimeters was made.