Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M
New VHF antenna was introduced at Uragan-2M for VHF vacuum chamber wall conditioning without and with weak magnetic field. It was made as a T-shaped ¼ wavelength double rod. The T-shaped antenna is capable for slow waves generation due to its longitudinal currents. This new wall conditioning tool...
Збережено в:
Дата: | 2018 |
---|---|
Автори: | , , , , , , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2018
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/148870 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M / A.V. Lozin, M.M. Kozulia, V.B. Korovin, A.A. Beletskii, G.P. Glazunov, A.L. Konotopskiy, D.I. Baron, V.E. Moiseenko, L.I. Grigor’eva, V.V. Chechkin, A.N. Shapoval, M.M. Makhov, V.G. Konovalov // Вопросы атомной науки и техники. — 2018. — № 6. — С. 50-53. — Бібліогр.: 4 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-148870 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-1488702019-02-19T01:27:18Z Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M Lozin, A.V. Kozulia, M.M. Korovin, V.B. Beletskii, A.A. Glazunov, G.P. Konotopskiy, A.L. Baron, D.I. Moiseenko, V.E. Grigor’eva, L.I. Chechkin, V.V. Shapoval, A.N. Makhov, M.M. Konovalov, V.G. Магнитное удержание New VHF antenna was introduced at Uragan-2M for VHF vacuum chamber wall conditioning without and with weak magnetic field. It was made as a T-shaped ¼ wavelength double rod. The T-shaped antenna is capable for slow waves generation due to its longitudinal currents. This new wall conditioning tool was studied analyzing vacuum chamber wall conditions and achieved plasma parameters. Для чистки вакуумної камери Урагану-2М у слабкому магнітному полі і без магнітного поля було впроваджено нову СВЧ-антену. Її було виконано у вигляді чвертьхвильового стрижня. Т-подібна антена здатна створювати повільні хвилі з повздовжніми струмами. Новий інструмент для чистки стінок вивчався через стан вакуумної камери і досягнутих параметрів плазми. Для чистки вакуумной камеры Урагана-2М в слабом магнитном поле и без магнитного поля была внедрена новая СВЧ-антенна. Она была выполнена в виде четвертьволнового стержня. Т-образная антенна способна создавать медленные волны с продольными токами. Новый инструмент для чистки стенок изучался посредством состояния вакуумной камеры и достигнутых параметров плазмы. 2018 Article Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M / A.V. Lozin, M.M. Kozulia, V.B. Korovin, A.A. Beletskii, G.P. Glazunov, A.L. Konotopskiy, D.I. Baron, V.E. Moiseenko, L.I. Grigor’eva, V.V. Chechkin, A.N. Shapoval, M.M. Makhov, V.G. Konovalov // Вопросы атомной науки и техники. — 2018. — № 6. — С. 50-53. — Бібліогр.: 4 назв. — англ. 1562-6016 PACS: 52.50.Sw http://dspace.nbuv.gov.ua/handle/123456789/148870 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
topic |
Магнитное удержание Магнитное удержание |
spellingShingle |
Магнитное удержание Магнитное удержание Lozin, A.V. Kozulia, M.M. Korovin, V.B. Beletskii, A.A. Glazunov, G.P. Konotopskiy, A.L. Baron, D.I. Moiseenko, V.E. Grigor’eva, L.I. Chechkin, V.V. Shapoval, A.N. Makhov, M.M. Konovalov, V.G. Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M Вопросы атомной науки и техники |
description |
New VHF antenna was introduced at Uragan-2M for VHF vacuum chamber wall conditioning without and with
weak magnetic field. It was made as a T-shaped ¼ wavelength double rod. The T-shaped antenna is capable for slow
waves generation due to its longitudinal currents. This new wall conditioning tool was studied analyzing vacuum
chamber wall conditions and achieved plasma parameters. |
format |
Article |
author |
Lozin, A.V. Kozulia, M.M. Korovin, V.B. Beletskii, A.A. Glazunov, G.P. Konotopskiy, A.L. Baron, D.I. Moiseenko, V.E. Grigor’eva, L.I. Chechkin, V.V. Shapoval, A.N. Makhov, M.M. Konovalov, V.G. |
author_facet |
Lozin, A.V. Kozulia, M.M. Korovin, V.B. Beletskii, A.A. Glazunov, G.P. Konotopskiy, A.L. Baron, D.I. Moiseenko, V.E. Grigor’eva, L.I. Chechkin, V.V. Shapoval, A.N. Makhov, M.M. Konovalov, V.G. |
author_sort |
Lozin, A.V. |
title |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M |
title_short |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M |
title_full |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M |
title_fullStr |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M |
title_full_unstemmed |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M |
title_sort |
wall conditioning discharges driven by т-shaped antenna in uragan-2m |
publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
publishDate |
2018 |
topic_facet |
Магнитное удержание |
url |
http://dspace.nbuv.gov.ua/handle/123456789/148870 |
citation_txt |
Wall conditioning discharges driven by Т-shaped antenna in Uragan-2M / A.V. Lozin, M.M. Kozulia, V.B. Korovin, A.A. Beletskii, G.P. Glazunov, A.L. Konotopskiy, D.I. Baron, V.E. Moiseenko, L.I. Grigor’eva, V.V. Chechkin, A.N. Shapoval, M.M. Makhov, V.G. Konovalov // Вопросы атомной науки и техники. — 2018. — № 6. — С. 50-53. — Бібліогр.: 4 назв. — англ. |
series |
Вопросы атомной науки и техники |
work_keys_str_mv |
AT lozinav wallconditioningdischargesdrivenbytshapedantennainuragan2m AT kozuliamm wallconditioningdischargesdrivenbytshapedantennainuragan2m AT korovinvb wallconditioningdischargesdrivenbytshapedantennainuragan2m AT beletskiiaa wallconditioningdischargesdrivenbytshapedantennainuragan2m AT glazunovgp wallconditioningdischargesdrivenbytshapedantennainuragan2m AT konotopskiyal wallconditioningdischargesdrivenbytshapedantennainuragan2m AT barondi wallconditioningdischargesdrivenbytshapedantennainuragan2m AT moiseenkove wallconditioningdischargesdrivenbytshapedantennainuragan2m AT grigorevali wallconditioningdischargesdrivenbytshapedantennainuragan2m AT chechkinvv wallconditioningdischargesdrivenbytshapedantennainuragan2m AT shapovalan wallconditioningdischargesdrivenbytshapedantennainuragan2m AT makhovmm wallconditioningdischargesdrivenbytshapedantennainuragan2m AT konovalovvg wallconditioningdischargesdrivenbytshapedantennainuragan2m |
first_indexed |
2023-05-20T17:31:10Z |
last_indexed |
2023-05-20T17:31:10Z |
_version_ |
1796153484467240960 |