W7-X plasma diagnostics for impurity transport studies

The Wendelstein 7-X (W7-X) stellarator which is located in Greifswald, Germany is an experimental device for demonstration of steady-state plasma operation. It was commissioned at the end of 2015 and at the beginning, it was operated in the limiter configuration (5 poloidal uncooled graphite limit...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2018
Автори: Kubkowska, M., Buttenschön, B., Langenberg, A., W7-X team
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2018
Назва видання:Вопросы атомной науки и техники
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/149074
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:W7-X plasma diagnostics for impurity transport studies / M. Kubkowska, B. Buttenschön, A. Langenberg and the W7-X team // Вопросы атомной науки и техники. — 2018. — № 6. — С. 312-316. — Бібліогр.: 19 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-149074
record_format dspace
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Диагностика плазмы
Диагностика плазмы
spellingShingle Диагностика плазмы
Диагностика плазмы
Kubkowska, M.
Buttenschön, B.
Langenberg, A.
W7-X team
W7-X plasma diagnostics for impurity transport studies
Вопросы атомной науки и техники
description The Wendelstein 7-X (W7-X) stellarator which is located in Greifswald, Germany is an experimental device for demonstration of steady-state plasma operation. It was commissioned at the end of 2015 and at the beginning, it was operated in the limiter configuration (5 poloidal uncooled graphite limiters) while starting from 2017 it has been equipped with a carbon uncooled divertor. With the launch of the device, new diagnostics have also been commissioned and tested. Understanding of impurity transport in stellarators is a crucial task in the optimisation process. At W7-X there are several spectroscopic systems which deliver information about plasma impurities. One of them is a pulse height analysis system (PHA) which collects soft X-ray spectra in the energy range from about 300 eV up to 20 keV with 100 ms temporal resolution. There are also X-ray imaging spectrometers XICS and HR-XIS which are devoted for measurements of spatio-temporal impurity emissivity of highly ionized ions with high temporal resolution (5 ms). Spectra in the VUV region are measured by the High-Efficiency XUV Overview Spectrometer (HEXOS).
format Article
author Kubkowska, M.
Buttenschön, B.
Langenberg, A.
W7-X team
author_facet Kubkowska, M.
Buttenschön, B.
Langenberg, A.
W7-X team
author_sort Kubkowska, M.
title W7-X plasma diagnostics for impurity transport studies
title_short W7-X plasma diagnostics for impurity transport studies
title_full W7-X plasma diagnostics for impurity transport studies
title_fullStr W7-X plasma diagnostics for impurity transport studies
title_full_unstemmed W7-X plasma diagnostics for impurity transport studies
title_sort w7-x plasma diagnostics for impurity transport studies
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2018
topic_facet Диагностика плазмы
url http://dspace.nbuv.gov.ua/handle/123456789/149074
citation_txt W7-X plasma diagnostics for impurity transport studies / M. Kubkowska, B. Buttenschön, A. Langenberg and the W7-X team // Вопросы атомной науки и техники. — 2018. — № 6. — С. 312-316. — Бібліогр.: 19 назв. — англ.
series Вопросы атомной науки и техники
work_keys_str_mv AT kubkowskam w7xplasmadiagnosticsforimpuritytransportstudies
AT buttenschonb w7xplasmadiagnosticsforimpuritytransportstudies
AT langenberga w7xplasmadiagnosticsforimpuritytransportstudies
AT w7xteam w7xplasmadiagnosticsforimpuritytransportstudies
first_indexed 2023-05-20T17:32:06Z
last_indexed 2023-05-20T17:32:06Z
_version_ 1796153504635551744
spelling irk-123456789-1490742019-02-20T01:28:23Z W7-X plasma diagnostics for impurity transport studies Kubkowska, M. Buttenschön, B. Langenberg, A. W7-X team Диагностика плазмы The Wendelstein 7-X (W7-X) stellarator which is located in Greifswald, Germany is an experimental device for demonstration of steady-state plasma operation. It was commissioned at the end of 2015 and at the beginning, it was operated in the limiter configuration (5 poloidal uncooled graphite limiters) while starting from 2017 it has been equipped with a carbon uncooled divertor. With the launch of the device, new diagnostics have also been commissioned and tested. Understanding of impurity transport in stellarators is a crucial task in the optimisation process. At W7-X there are several spectroscopic systems which deliver information about plasma impurities. One of them is a pulse height analysis system (PHA) which collects soft X-ray spectra in the energy range from about 300 eV up to 20 keV with 100 ms temporal resolution. There are also X-ray imaging spectrometers XICS and HR-XIS which are devoted for measurements of spatio-temporal impurity emissivity of highly ionized ions with high temporal resolution (5 ms). Spectra in the VUV region are measured by the High-Efficiency XUV Overview Spectrometer (HEXOS). Стеларатор Wendelstein 7-X (W7-X), який розташований в Грайфсвальді, Німеччина, є експериментальною установкою для демонстрації стаціонарного утримання плазми. Стеларатор було введено в експлуатацію в кінці 2015 року та спочатку експлуатувався в конфігурації з обмежувачем (5 полоідальних неохолоджуваних графітових обмежувачів). З 2017 року установка була оснащена вуглецевим неохолоджуваним дивертором. Із запуском стеларатора були також введені в експлуатацію і випробувані нові діагностичні системи. Розуміння транспорту домішок y стелараторі є важливим завданням для оптимізації його роботи. На W7-X є декілька спектроскопічних систем, які надають інформацію про домішки в плазмі. Одна з них – система аналізу висоти спостережуваного імпульсу (PHA) – реєструє спектри м'якого рентгенівського випромінювання в діапазоні енергій від близько 300 еВ до 20 кеВ з часовою роздільною здатністю 100 мс. Є також рентгенографічні спектрометри XICS і HR-XIS, призначені для виміру просторово-часової випромінювальної здатності домішок, геліоподібних іонів з високою часовою роздільною здатністю (5 мс). Спектри в області VUV вимірюють за допомогою високоефективного оглядового спектроаналізатора (HEXOS). Стелларатор Wendelstein 7-X (W7-X), который расположен в Грайфсвальде, Германия, является экспериментальной установкой для демонстрации стационарного удержания плазмы. Стелларатор был введен в эксплуатацию в конце 2015 года, и вначале эксплуатировался в конфигурации с ограничителем (5 полоидальных неохлаждаемых графитовых ограничителей). С 2017 года установка оснащена углеродным неохлаждаемым дивертором. С запуском стелларатора были также введены в эксплуатацию и испытаны новые диагностические системы. Понимание транспорта примесей в стеллараторе является важной задачей для оптимизации его работы. На W7-X имеется несколько спектроскопических систем, которые предоставляют информацию о примесях в плазме. Одна из них – система анализа высоты наблюдаемого импульса (PHA) – регистрирует спектры мягкого рентгеновского излучения в диапазоне энергий от около 300 эВ до 20 кэВ с временным разрешением 100 мс. Имеются также рентгенографические спектрометры XICS и HR-XIS, предназначенные для измерения пространственновременной примесной излучательной способности гелиоподобных ионов с высоким временным разрешением (5 мс). Спектры в области VUV измеряют с помощью высокоэффективного обзорного спектроанализатора (HEXOS). 2018 Article W7-X plasma diagnostics for impurity transport studies / M. Kubkowska, B. Buttenschön, A. Langenberg and the W7-X team // Вопросы атомной науки и техники. — 2018. — № 6. — С. 312-316. — Бібліогр.: 19 назв. — англ. 1562-6016 PACS: 52.25.Vy, 52.25.Xz, 52.55.Hc, 52.25.Fi, 52.70.−m http://dspace.nbuv.gov.ua/handle/123456789/149074 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України