Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination
The characteristics of conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serum albumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatic...
Збережено в:
Дата: | 1996 |
---|---|
Автори: | , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Інститут молекулярної біології і генетики НАН України
1996
|
Назва видання: | Биополимеры и клетка |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/153663 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A. Zhylyak, A.P. Soldatkin // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-153663 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-1536632019-07-04T20:44:58Z Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. The characteristics of conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serum albumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatically catalyzed hydrolysis of urea. This process for both immobilized enzyme and soluble one is described by the classic laws of enzymatic kinetics. The influence of ionic strength, pH and buffer capacity of the samples on the biosensor response has been thoroughly tested. The results have been discussed concerning urea concentration analysis in human blood. 1996 Article Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A. Zhylyak, A.P. Soldatkin // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. 0233-7657 http://dspace.nbuv.gov.ua/handle/123456789/153663 577.15+573.6 en Биополимеры и клетка Інститут молекулярної біології і генетики НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
description |
The characteristics of conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serum albumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatically catalyzed hydrolysis of urea. This process for both immobilized enzyme and soluble one is described by the classic laws of enzymatic kinetics. The influence of ionic strength, pH and buffer capacity of the samples on the biosensor response has been thoroughly tested. The results have been discussed concerning urea concentration analysis in human blood. |
format |
Article |
author |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. |
spellingShingle |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination Биополимеры и клетка |
author_facet |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. |
author_sort |
Dzyadevich, S.V. |
title |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_short |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_full |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_fullStr |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_full_unstemmed |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_sort |
conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
publisher |
Інститут молекулярної біології і генетики НАН України |
publishDate |
1996 |
url |
http://dspace.nbuv.gov.ua/handle/123456789/153663 |
citation_txt |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A. Zhylyak, A.P. Soldatkin // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. |
series |
Биополимеры и клетка |
work_keys_str_mv |
AT dzyadevichsv conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination AT zhylyakga conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination AT soldatkinap conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination |
first_indexed |
2023-05-20T17:42:15Z |
last_indexed |
2023-05-20T17:42:15Z |
_version_ |
1796153903022080000 |