Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination
The characteristics of conductometric urease microbiosensor based on thin-film inter-digitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serumalbumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatic...
Збережено в:
Дата: | 1996 |
---|---|
Автори: | , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Інститут молекулярної біології і генетики НАН України
1996
|
Назва видання: | Биополимеры и клетка |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/153794 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A Zhylyak., A.P. Soldatkin, A.V. El'skaya // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-153794 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-1537942019-06-15T01:31:18Z Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. El'skaya, A.V. The characteristics of conductometric urease microbiosensor based on thin-film inter-digitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serumalbumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatically catalyzed hydrolysis of urea. This process for both immobilized enzyme and soluble one is described by the classic laws of enzymatic kinetics. The influence of ionic strength, pH and buffer capacity of the samples on the biosensor response has been thoroughly tested. The results have been discussed concerning urea concentration analysis in human blood. Вивчено характеристики кондуктометричного уреазного біосенсора для визначення сечовини на основі тонкоплівкових гребінчастих електродів. Уреазу іммобілізовали ковалентною зшивкою з сироватковим альбуміном бика за допомогою глутарового альдегіду. Результуючі зміни провідності викликано ферментативним гідролізом сечовини. Згаданий процес як для іммобілізова ного, так і для вільного ферменту описується класичними законами ферментативної кінетики. Досліджено вплив на величину відгуку іонної сили, рН та буферної ємності розчину. Розглянуто питання стосовно визначення концентрації сечовини у крові людини. Изучены характеристики кондуктометрического уреазного микробиосенсора для определения мочевины на основе тонкопленочных гребенчатых электродов. Уреазу иммобилизовали ковалентной сшивкой с бычьим сывороточным альбумином с помощью глутарового альдегида. Результирующее изменение проводимости вызвано ферментативным гидролизом мочевины. Этот процесс как для иммобилизованного, так и для свободного фермента описывается классическими законами ферментативной кинетики. Исследовано влияние на величину отклика ионной силы, рН и буферной емкости раствора Рассмотрены вопросы, связанные с определением концентра ции мочевины в крови человека. 1996 Article Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A Zhylyak., A.P. Soldatkin, A.V. El'skaya // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. 0233-7657 DOI: http://dx.doi.org/10.7124/bc.000412 http://dspace.nbuv.gov.ua/handle/123456789/153794 577.15+573.6 en Биополимеры и клетка Інститут молекулярної біології і генетики НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
description |
The characteristics of conductometric urease microbiosensor based on thin-film inter-digitated electrodes for urea determination have been studied. Urease has been immobilized by cross-linking with bovine serumalbumin using glutaraldehyde. The resulting conductivity changes are produced by enzymatically catalyzed hydrolysis of urea. This process for both immobilized enzyme and soluble one is described by the classic laws of enzymatic kinetics. The influence of ionic strength, pH and buffer capacity of the samples on the biosensor response has been thoroughly tested. The results have been discussed concerning urea concentration analysis in human blood. |
format |
Article |
author |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. El'skaya, A.V. |
spellingShingle |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. El'skaya, A.V. Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination Биополимеры и клетка |
author_facet |
Dzyadevich, S.V. Zhylyak, G.A. Soldatkin, A.P. El'skaya, A.V. |
author_sort |
Dzyadevich, S.V. |
title |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_short |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_full |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_fullStr |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_full_unstemmed |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
title_sort |
conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination |
publisher |
Інститут молекулярної біології і генетики НАН України |
publishDate |
1996 |
url |
http://dspace.nbuv.gov.ua/handle/123456789/153794 |
citation_txt |
Conductometric urease microbiosensor based on thin-film interdigitated electrodes for urea determination / S.V. Dzyadevich, G.A Zhylyak., A.P. Soldatkin, A.V. El'skaya // Биополимеры и клетка. — 1996. — Т. 12, № 1. — С. 53-57. — Бібліогр.: 9 назв. — англ. |
series |
Биополимеры и клетка |
work_keys_str_mv |
AT dzyadevichsv conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination AT zhylyakga conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination AT soldatkinap conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination AT elskayaav conductometricureasemicrobiosensorbasedonthinfilminterdigitatedelectrodesforureadetermination |
first_indexed |
2023-05-20T17:42:40Z |
last_indexed |
2023-05-20T17:42:40Z |
_version_ |
1796153914283786240 |