Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination

Aim. The development and optimization of the amperometric biosensor for pyruvate determina-tion. Methods. Immobilized pyruvate oxidase was used as a biorecognition element of the biosen-sor, a platinum disc electrode- as an electrochemical transducer. Results. Different variants of immobilization of...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2018
Автори: Knyzhnykova, D.V., Topolnikova, Ya.V., Kucherenko, I.S., Soldatkin, O.O.
Формат: Стаття
Мова:English
Опубліковано: Інститут молекулярної біології і генетики НАН України 2018
Назва видання:Вiopolymers and Cell
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/154261
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination / D.V. Knyzhnykova, Ya.V. Topolnikova, I.S. Kucherenko, O.O. Soldatkin // Вiopolymers and Cell. — 2018. — Т. 34, № 1. — С. 14-23. — Бібліогр.: 9 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-154261
record_format dspace
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Molecular and Cell Biotechnologies
Molecular and Cell Biotechnologies
spellingShingle Molecular and Cell Biotechnologies
Molecular and Cell Biotechnologies
Knyzhnykova, D.V.
Topolnikova, Ya.V.
Kucherenko, I.S.
Soldatkin, O.O.
Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
Вiopolymers and Cell
description Aim. The development and optimization of the amperometric biosensor for pyruvate determina-tion. Methods. Immobilized pyruvate oxidase was used as a biorecognition element of the biosen-sor, a platinum disc electrode- as an electrochemical transducer. Results. Different variants of immobilization of pyruvate oxidase were tested and the optimal one was chosen for the creation of a biorecognition element of the biosensor. Optimal concentrations of cofactors for the best per-formance of the pyruvate oxidase-based biosensor were selected. The developed biosensor dem-onstrated a high sensitivity to pyruvate and wide linear range of work. High selectivity of the pro-posed biosensor towards electrically active substances and other substrates present in real samples was shown. The biosensor is characterized by high signal reproducibility and operational stability over two weeks. Conclusions. The highly selective amperometric biosensor for determination of pyruvate in biological samples has been developed. Its analytical characteristics are studied. The biosensor can be further used for the pyruvate analysis in blood serum.
format Article
author Knyzhnykova, D.V.
Topolnikova, Ya.V.
Kucherenko, I.S.
Soldatkin, O.O.
author_facet Knyzhnykova, D.V.
Topolnikova, Ya.V.
Kucherenko, I.S.
Soldatkin, O.O.
author_sort Knyzhnykova, D.V.
title Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
title_short Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
title_full Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
title_fullStr Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
title_full_unstemmed Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
title_sort development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
publisher Інститут молекулярної біології і генетики НАН України
publishDate 2018
topic_facet Molecular and Cell Biotechnologies
url http://dspace.nbuv.gov.ua/handle/123456789/154261
citation_txt Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination / D.V. Knyzhnykova, Ya.V. Topolnikova, I.S. Kucherenko, O.O. Soldatkin // Вiopolymers and Cell. — 2018. — Т. 34, № 1. — С. 14-23. — Бібліогр.: 9 назв. — англ.
series Вiopolymers and Cell
work_keys_str_mv AT knyzhnykovadv developmentofpyruvateoxidasebasedamperometricbiosensorforpyruvatedetermination
AT topolnikovayav developmentofpyruvateoxidasebasedamperometricbiosensorforpyruvatedetermination
AT kucherenkois developmentofpyruvateoxidasebasedamperometricbiosensorforpyruvatedetermination
AT soldatkinoo developmentofpyruvateoxidasebasedamperometricbiosensorforpyruvatedetermination
first_indexed 2023-05-20T17:44:02Z
last_indexed 2023-05-20T17:44:02Z
_version_ 1796153965293862912
spelling irk-123456789-1542612019-07-07T12:38:49Z Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination Knyzhnykova, D.V. Topolnikova, Ya.V. Kucherenko, I.S. Soldatkin, O.O. Molecular and Cell Biotechnologies Aim. The development and optimization of the amperometric biosensor for pyruvate determina-tion. Methods. Immobilized pyruvate oxidase was used as a biorecognition element of the biosen-sor, a platinum disc electrode- as an electrochemical transducer. Results. Different variants of immobilization of pyruvate oxidase were tested and the optimal one was chosen for the creation of a biorecognition element of the biosensor. Optimal concentrations of cofactors for the best per-formance of the pyruvate oxidase-based biosensor were selected. The developed biosensor dem-onstrated a high sensitivity to pyruvate and wide linear range of work. High selectivity of the pro-posed biosensor towards electrically active substances and other substrates present in real samples was shown. The biosensor is characterized by high signal reproducibility and operational stability over two weeks. Conclusions. The highly selective amperometric biosensor for determination of pyruvate in biological samples has been developed. Its analytical characteristics are studied. The biosensor can be further used for the pyruvate analysis in blood serum. Мета. Розробка та оптимізація роботи амперометричного біосенсора для визначення пірувату. Методи. Застосовано амперометричний біосенсор з іммобілізованою піруватоксидазою як біоселективний елемент та платинові дискові електроди як перетворювачі. Результати. Перевірено різні варіанти іммобілізації піруватоксидази та обрано оптимальний для створення біоселективного елементу біосенсора. Підібрано оптимальні концентрації кофакторів для найкращої роботи біосенсора на основі піруватоксидази. Розроблений біосенсор демонстрував високу чутливість до пірувату та широкий лінійний діапазон роботи. Було показано високу селективність запропонованого біосенсора відносно електроактивних речовин та інших субстратів, що можуть бути присутніми в реальних зразках. Біосенсор характеризується високою відтворюваністю сигналу та операційною стабільністю протягом 2 тижнів. Висновки. Розроблено високоселективний амперометричний біосенсор для визначення пірувату у біологічних зразках та досліджено його аналітичні характеристики. В подальшому даний біосенсор може бути використано для визначення пірувату у сироватці крові. Цель. Разработка и оптимизация работы амперометрического біосенсора для определения пирувата. Методы. Использовано амперометрический біосенсор с иммобилизованной пируватоксидазой как биоселективным элементом и платиновые дисковые электроды как преобразователи. Результаты. Проверено разные варианты иммобилизации пируватоксидазы и выбрано оптимальный для создания биоселективного элемента биосенсора. Подобрано оптимальные концентрации кофакторов для наилучшей работы биосенсора на основе пируватоксидазы. Разработанный биосенсор демонстрировал высокую чувствительность к пирувату и широкий линейный диапазон работы. Было показано хорошую селективность предложенного биосенсора относительно электроактивных веществ и других субстратов, которые могут присутствовать в реальных образцах. Биосенсор характеризуется высокой воспроизводимостью сигнала и операционной стабильностью на протяжении двух недель. Выводы. Разработан высокоселективный амперометрический биосенсор для определения пирувата в биологических образцах и исследованы его аналитические характеристики. В дальнейшем данный биосенсор может быть использован для определения пирувата в сыворотке крови. 2018 Article Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination / D.V. Knyzhnykova, Ya.V. Topolnikova, I.S. Kucherenko, O.O. Soldatkin // Вiopolymers and Cell. — 2018. — Т. 34, № 1. — С. 14-23. — Бібліогр.: 9 назв. — англ. 0233-7657 DOI: http://dx.doi.org/10.7124/bc.00096C http://dspace.nbuv.gov.ua/handle/123456789/154261 543.06 + 577.15 + 543.553 en Вiopolymers and Cell Інститут молекулярної біології і генетики НАН України