Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena

The article has investigated the removal of water borne pathogens using dielectrophoresis (DEP) filter which is energized by varying the frequency of the applied potential from 10 kHz to 2 MHz with different voltage levels of 5; 10; 15 and 20 V. Separate experiments are conducted in artificially co...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автори: Sankaranarayanan, A., Prabu Sankarlal, K.M., Raja, D.
Формат: Стаття
Мова:English
Опубліковано: Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України 2016
Назва видання:Химия и технология воды
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/160777
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena / A. Sankaranarayanan, K.M. Prabu Sankarlal, D. Raja // Химия и технология воды. — 2016. — Т. 38, № 2. — С. 210-219. — Бібліогр.: 16 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-160777
record_format dspace
spelling irk-123456789-1607772019-11-20T01:25:54Z Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena Sankaranarayanan, A. Prabu Sankarlal, K.M. Raja, D. Биологические методы очистки воды The article has investigated the removal of water borne pathogens using dielectrophoresis (DEP) filter which is energized by varying the frequency of the applied potential from 10 kHz to 2 MHz with different voltage levels of 5; 10; 15 and 20 V. Separate experiments are conducted in artificially contaminated water samples with Escherichia coli, Staphylococcus aureus and Vibrio cholera up to 2 h. The impact of signal frequency and voltages on DEP based water treatment system has been analyzed statistically. Results have demonstrated that an ac signal of 20 V with frequency range of 500 kHz to 2 MHZ is suitable to remove the tested bacterial population and the rate of removal of E. coli is the highest with a dielectrophoretic filtration efficiency of 77,1%. 2016 Article Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena / A. Sankaranarayanan, K.M. Prabu Sankarlal, D. Raja // Химия и технология воды. — 2016. — Т. 38, № 2. — С. 210-219. — Бібліогр.: 16 назв. — англ. 0204-3556 http://dspace.nbuv.gov.ua/handle/123456789/160777 en Химия и технология воды Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Биологические методы очистки воды
Биологические методы очистки воды
spellingShingle Биологические методы очистки воды
Биологические методы очистки воды
Sankaranarayanan, A.
Prabu Sankarlal, K.M.
Raja, D.
Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
Химия и технология воды
description The article has investigated the removal of water borne pathogens using dielectrophoresis (DEP) filter which is energized by varying the frequency of the applied potential from 10 kHz to 2 MHz with different voltage levels of 5; 10; 15 and 20 V. Separate experiments are conducted in artificially contaminated water samples with Escherichia coli, Staphylococcus aureus and Vibrio cholera up to 2 h. The impact of signal frequency and voltages on DEP based water treatment system has been analyzed statistically. Results have demonstrated that an ac signal of 20 V with frequency range of 500 kHz to 2 MHZ is suitable to remove the tested bacterial population and the rate of removal of E. coli is the highest with a dielectrophoretic filtration efficiency of 77,1%.
format Article
author Sankaranarayanan, A.
Prabu Sankarlal, K.M.
Raja, D.
author_facet Sankaranarayanan, A.
Prabu Sankarlal, K.M.
Raja, D.
author_sort Sankaranarayanan, A.
title Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
title_short Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
title_full Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
title_fullStr Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
title_full_unstemmed Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
title_sort impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena
publisher Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
publishDate 2016
topic_facet Биологические методы очистки воды
url http://dspace.nbuv.gov.ua/handle/123456789/160777
citation_txt Impact of different frequencies in the entrapment of bacterial pathogens from drinking water using dielectrophoretic phenomena / A. Sankaranarayanan, K.M. Prabu Sankarlal, D. Raja // Химия и технология воды. — 2016. — Т. 38, № 2. — С. 210-219. — Бібліогр.: 16 назв. — англ.
series Химия и технология воды
work_keys_str_mv AT sankaranarayanana impactofdifferentfrequenciesintheentrapmentofbacterialpathogensfromdrinkingwaterusingdielectrophoreticphenomena
AT prabusankarlalkm impactofdifferentfrequenciesintheentrapmentofbacterialpathogensfromdrinkingwaterusingdielectrophoreticphenomena
AT rajad impactofdifferentfrequenciesintheentrapmentofbacterialpathogensfromdrinkingwaterusingdielectrophoreticphenomena
first_indexed 2023-06-10T11:09:46Z
last_indexed 2023-06-10T11:09:46Z
_version_ 1796154615935270912