Secondary emission magnetron injection gun that controlled by magnetic field in long pulse mode
The origin variant of ignition the secondary emission magnetron injection gun at low voltage (3…25 kV) with use pulse magnetic filed and additional gas filling is described. Beam current up to 5 A with pulse its duration up to 10 ms was achieved. Perspectives of the gun application for generation of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2010
|
Subjects: | |
Online Access: | http://dspace.nbuv.gov.ua/handle/123456789/17010 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The origin variant of ignition the secondary emission magnetron injection gun at low voltage (3…25 kV) with use pulse magnetic filed and additional gas filling is described. Beam current up to 5 A with pulse its duration up to 10 ms was achieved. Perspectives of the gun application for generation of electron beams and high charge ions are discussed. |
---|