Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping

A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power ac...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:1997
Автори: Batey, G.J., White, J.P., Duncan, W.D., Simpson, A.F., Mikheev, V.A.
Формат: Стаття
Мова:English
Опубліковано: Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України 1997
Назва видання:Физика низких температур
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/175577
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-175577
record_format dspace
spelling irk-123456789-1755772021-02-02T01:27:44Z Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping Batey, G.J. White, J.P. Duncan, W.D. Simpson, A.F. Mikheev, V.A. Техника свеpхнизких темпеpатуp A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power achieved is 40 at 100 mK. The DR is fitted with 6-mm line-of-sight access down to the mixing chamber. A distinguishing feature of this refrigerator is the absence of a conventional gas-handling system, which makes it easy to transport in a small car and quickly commission in a new laboratory within a few hours. 1997 Article Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ. 0132-6414 PACS: 07.20.Мс http://dspace.nbuv.gov.ua/handle/123456789/175577 en Физика низких температур Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Техника свеpхнизких темпеpатуp
Техника свеpхнизких темпеpатуp
spellingShingle Техника свеpхнизких темпеpатуp
Техника свеpхнизких темпеpатуp
Batey, G.J.
White, J.P.
Duncan, W.D.
Simpson, A.F.
Mikheev, V.A.
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
Физика низких температур
description A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power achieved is 40 at 100 mK. The DR is fitted with 6-mm line-of-sight access down to the mixing chamber. A distinguishing feature of this refrigerator is the absence of a conventional gas-handling system, which makes it easy to transport in a small car and quickly commission in a new laboratory within a few hours.
format Article
author Batey, G.J.
White, J.P.
Duncan, W.D.
Simpson, A.F.
Mikheev, V.A.
author_facet Batey, G.J.
White, J.P.
Duncan, W.D.
Simpson, A.F.
Mikheev, V.A.
author_sort Batey, G.J.
title Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
title_short Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
title_full Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
title_fullStr Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
title_full_unstemmed Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
title_sort ultralow temperatures in a transport vessel: a dilution refrigerator to achieve 30 mk by continuous adsorption pumping
publisher Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України
publishDate 1997
topic_facet Техника свеpхнизких темпеpатуp
url http://dspace.nbuv.gov.ua/handle/123456789/175577
citation_txt Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ.
series Физика низких температур
work_keys_str_mv AT bateygj ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping
AT whitejp ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping
AT duncanwd ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping
AT simpsonaf ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping
AT mikheevva ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping
first_indexed 2023-10-18T22:39:09Z
last_indexed 2023-10-18T22:39:09Z
_version_ 1796156079639363584